WEKO3
アイテム
{"_buckets": {"deposit": "f93befa5-2bb0-4612-81f4-8f38efe89bb9"}, "_deposit": {"created_by": 2, "id": "10174", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "10174"}, "status": "published"}, "_oai": {"id": "oai:nagasaki-u.repo.nii.ac.jp:00010174", "sets": ["30"]}, "author_link": ["40809", "40808", "40807"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-05", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "05", "bibliographicPageEnd": "350", "bibliographicPageStart": "346", "bibliographicVolumeNumber": "33", "bibliographic_titles": [{"bibliographic_title": "International Journal of Sports Medicine"}]}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The purpose of this study was to investigate the reproducibility and utility of a standardised and externally paced field test (15-m Incremental Shuttle Walk and Run Test [15 mISWRT]) to assess aerobic fitness in middle-aged adults. 14 middle-aged participants performed the 15-m ISWRT 3 times within one week (Test 1, Test 2, Test 3). Reproducibility of the 15-m ISWRT was tested by comparing 15-m ISWRT performance (distance completed), HRmax, and V˙O2max for each test. The utility of the 15-m ISWRT for evaluating V˙O2max over a wide range in middle-aged adults was tested by comparing the range of V˙O2max obtained from the portable expired gas analyzer with the V˙O2max reference values and ranges for health promotion published by Japan\u0027s Ministry of Health, Labour and Welfare. A multiple comparison of distance completed in the 15-m ISWRT Test 1, Test 2, and Test 3 found no significant difference between Test 2 and Test 3. The ICC was 0.99 for Test 2 vs. Test 3. V˙O2max measured from the 15-m ISWRT in Test 3 had a minimum value of 22.8 ml/kg/min and a maximum value of 38.7 ml/kg/min. In conclusion, the 15-m ISWRT is reliable and useful for evaluating V˙O2max in middle-aged adults.", "subitem_description_type": "Abstract"}]}, "item_2_description_63": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "International Journal of Sports Medicine, 33(05), pp.346-350; 2012", "subitem_description_type": "Other"}]}, "item_2_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Georg Thieme Verlag"}]}, "item_2_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1055/s-0031-1301321", "subitem_relation_type_select": "DOI"}}]}, "item_2_relation_42": {"attribute_name": "関係URI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "http://hdl.handle.net/10069/29705"}]}]}, "item_2_rights_13": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "© Georg Thieme Verlag KG Stuttgart · New York"}]}, "item_2_source_id_10": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA00234368", "subitem_source_identifier_type": "NCID"}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "01724622", "subitem_source_identifier_type": "ISSN"}]}, "item_2_source_id_8": {"attribute_name": "EISSN", "attribute_value_mlt": [{"subitem_source_identifier": "14393964", "subitem_source_identifier_type": "ISSN"}]}, "item_2_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mikawa, Kotaro"}], "nameIdentifiers": [{"nameIdentifier": "40807", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yano, Yudai"}], "nameIdentifiers": [{"nameIdentifier": "40808", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Senjyu, Hideaki"}], "nameIdentifiers": [{"nameIdentifier": "40809", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-12-22"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "JSpoMed33_346.pdf", "filesize": [{"value": "266.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 266600.0, "url": {"label": "JSpoMed33_346.pdf", "url": "https://nagasaki-u.repo.nii.ac.jp/record/10174/files/JSpoMed33_346.pdf"}, "version_id": "f2eb0e97-5348-4910-9e84-d0d8d7d86792"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "maximal oxygen uptake", "subitem_subject_scheme": "Other"}, {"subitem_subject": "middle-aged adults", "subitem_subject_scheme": "Other"}, {"subitem_subject": "portable expired gas analyzer", "subitem_subject_scheme": "Other"}, {"subitem_subject": "reproducibility", "subitem_subject_scheme": "Other"}, {"subitem_subject": "shuttle walking test", "subitem_subject_scheme": "Other"}, {"subitem_subject": "utility", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Development of a Field Test for Evaluating Aerobic Fitness", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Development of a Field Test for Evaluating Aerobic Fitness"}]}, "item_type_id": "2", "owner": "2", "path": ["30"], "permalink_uri": "http://hdl.handle.net/10069/28635", "pubdate": {"attribute_name": "公開日", "attribute_value": "2013-07-01"}, "publish_date": "2013-07-01", "publish_status": "0", "recid": "10174", "relation": {}, "relation_version_is_last": true, "title": ["Development of a Field Test for Evaluating Aerobic Fitness"], "weko_shared_id": -1}
Development of a Field Test for Evaluating Aerobic Fitness
http://hdl.handle.net/10069/28635
http://hdl.handle.net/10069/286351de3b431-19b0-42fc-9ac0-744b96a78414
名前 / ファイル | ライセンス | アクション |
---|---|---|
JSpoMed33_346.pdf (266.6 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-07-01 | |||||
タイトル | ||||||
タイトル | Development of a Field Test for Evaluating Aerobic Fitness | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | maximal oxygen uptake | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | middle-aged adults | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | portable expired gas analyzer | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | reproducibility | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | shuttle walking test | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | utility | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Mikawa, Kotaro
× Mikawa, Kotaro× Yano, Yudai× Senjyu, Hideaki |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The purpose of this study was to investigate the reproducibility and utility of a standardised and externally paced field test (15-m Incremental Shuttle Walk and Run Test [15 mISWRT]) to assess aerobic fitness in middle-aged adults. 14 middle-aged participants performed the 15-m ISWRT 3 times within one week (Test 1, Test 2, Test 3). Reproducibility of the 15-m ISWRT was tested by comparing 15-m ISWRT performance (distance completed), HRmax, and V˙O2max for each test. The utility of the 15-m ISWRT for evaluating V˙O2max over a wide range in middle-aged adults was tested by comparing the range of V˙O2max obtained from the portable expired gas analyzer with the V˙O2max reference values and ranges for health promotion published by Japan's Ministry of Health, Labour and Welfare. A multiple comparison of distance completed in the 15-m ISWRT Test 1, Test 2, and Test 3 found no significant difference between Test 2 and Test 3. The ICC was 0.99 for Test 2 vs. Test 3. V˙O2max measured from the 15-m ISWRT in Test 3 had a minimum value of 22.8 ml/kg/min and a maximum value of 38.7 ml/kg/min. In conclusion, the 15-m ISWRT is reliable and useful for evaluating V˙O2max in middle-aged adults. | |||||
書誌情報 |
International Journal of Sports Medicine 巻 33, 号 05, p. 346-350, 発行日 2012-05 |
|||||
出版者 | ||||||
出版者 | Georg Thieme Verlag | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 01724622 | |||||
EISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 14393964 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA00234368 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1055/s-0031-1301321 | |||||
権利 | ||||||
権利情報 | © Georg Thieme Verlag KG Stuttgart · New York | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
関係URI | ||||||
関連名称 | http://hdl.handle.net/10069/29705 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | International Journal of Sports Medicine, 33(05), pp.346-350; 2012 |