{"_buckets": {"deposit": "c55097f7-8e76-4260-9ee0-84b16b021607"}, "_deposit": {"created_by": 6, "id": "26683", "owners": [6], "pid": {"revision_id": 0, "type": "depid", "value": "26683"}, "status": "published"}, "_oai": {"id": "oai:nagasaki-u.repo.nii.ac.jp:00026683", "sets": ["2004"]}, "author_link": ["118172", "118171"], "item_3_alternative_title_19": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Numerical Calculation on the Effects of Night Purge in Loft Space during Summer on Room Temperature and Cooling Load"}]}, "item_3_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2021-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "97", "bibliographicPageEnd": "38", "bibliographicPageStart": "33", "bibliographicVolumeNumber": "51", "bibliographic_titles": [{"bibliographic_title": "長崎大学大学院工学研究科研究報告"}, {"bibliographic_title": "Reports of Graduate School of Engineering, Nagasaki University", "bibliographic_titleLang": "en"}]}]}, "item_3_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Numerical simulation was carried out using multi-zone heat calculation program TRNSYS, the effects of night purge in loft space during summer on room temperature and cooling load were compared among six cities in Japan. The room temperature reduction effect of night purge was remarkable between 10 times/h and 50 times/h of ventilation rate, and not so much when the ventilation rate was between 50 times/h and 200 times/h. It was found that increasing the size of the loft window or providing it face-to-face during night purge slightly reduces the room temperature at night, but increases the room temperature during the day. It was also found that as the nighttime ventilation rate increased in both August and September, the cooling load decreased.", "subitem_description_type": "Abstract"}]}, "item_3_description_64": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "長崎大学大学院工学研究科研究報告, 51(97), pp.33-38; 2021", "subitem_description_type": "Other"}]}, "item_3_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "118172", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "GENJO, Kahori"}]}]}, "item_3_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "長崎大学大学院工学研究科"}]}, "item_3_source_id_10": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA12601998", "subitem_source_identifier_type": "NCID"}]}, "item_3_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "18805574", "subitem_source_identifier_type": "ISSN"}]}, "item_3_text_62": {"attribute_name": "sortkey", "attribute_value_mlt": [{"subitem_text_value": "06"}]}, "item_3_text_63": {"attribute_name": "出版者別言語", "attribute_value_mlt": [{"subitem_text_value": "Graduate School of Engineering, Nagasaki University"}]}, "item_3_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "源城, かほり"}], "nameIdentifiers": [{"nameIdentifier": "118171", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2021-08-19"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "51_97_33.pdf", "filesize": [{"value": "747.1 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 747100.0, "url": {"label": "51_97_33.pdf", "url": "https://nagasaki-u.repo.nii.ac.jp/record/26683/files/51_97_33.pdf"}, "version_id": "6eb5c801-e946-46dd-a0f9-1debaaff62c5"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "loft", "subitem_subject_scheme": "Other"}, {"subitem_subject": "night purge", "subitem_subject_scheme": "Other"}, {"subitem_subject": "numerical calculation", "subitem_subject_scheme": "Other"}, {"subitem_subject": "cooling load", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ventilation rate", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "夏季のロフト空間における夜間換気が室温と冷房負荷に及ぼす影響に関する数値計算", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "夏季のロフト空間における夜間換気が室温と冷房負荷に及ぼす影響に関する数値計算"}]}, "item_type_id": "3", "owner": "6", "path": ["2004"], "permalink_uri": "http://hdl.handle.net/10069/00040861", "pubdate": {"attribute_name": "公開日", "attribute_value": "2021-08-19"}, "publish_date": "2021-08-19", "publish_status": "0", "recid": "26683", "relation": {}, "relation_version_is_last": true, "title": ["夏季のロフト空間における夜間換気が室温と冷房負荷に及ぼす影響に関する数値計算"], "weko_shared_id": -1}
夏季のロフト空間における夜間換気が室温と冷房負荷に及ぼす影響に関する数値計算
http://hdl.handle.net/10069/00040861
http://hdl.handle.net/10069/0004086133a1cd9d-1635-4c5c-b23a-071d913ff881
名前 / ファイル | ライセンス | アクション |
---|---|---|
51_97_33.pdf (747.1 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-08-19 | |||||
タイトル | ||||||
タイトル | 夏季のロフト空間における夜間換気が室温と冷房負荷に及ぼす影響に関する数値計算 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | loft | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | night purge | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | numerical calculation | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | cooling load | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | ventilation rate | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
源城, かほり
× 源城, かほり |
|||||
著者別名 | ||||||
姓名 | GENJO, Kahori | |||||
その他のタイトル | ||||||
その他のタイトル | Numerical Calculation on the Effects of Night Purge in Loft Space during Summer on Room Temperature and Cooling Load | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Numerical simulation was carried out using multi-zone heat calculation program TRNSYS, the effects of night purge in loft space during summer on room temperature and cooling load were compared among six cities in Japan. The room temperature reduction effect of night purge was remarkable between 10 times/h and 50 times/h of ventilation rate, and not so much when the ventilation rate was between 50 times/h and 200 times/h. It was found that increasing the size of the loft window or providing it face-to-face during night purge slightly reduces the room temperature at night, but increases the room temperature during the day. It was also found that as the nighttime ventilation rate increased in both August and September, the cooling load decreased. | |||||
書誌情報 |
長崎大学大学院工学研究科研究報告 en : Reports of Graduate School of Engineering, Nagasaki University 巻 51, 号 97, p. 33-38, 発行日 2021-07 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 18805574 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12601998 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | 長崎大学大学院工学研究科 | |||||
出版者別言語 | ||||||
Graduate School of Engineering, Nagasaki University | ||||||
sortkey | ||||||
06 | ||||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 長崎大学大学院工学研究科研究報告, 51(97), pp.33-38; 2021 |