WEKO3
アイテム
{"_buckets": {"deposit": "4d5a430c-01a8-48cd-813c-a956c41eda0d"}, "_deposit": {"created_by": 2, "id": "5271", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "5271"}, "status": "published"}, "_oai": {"id": "oai:nagasaki-u.repo.nii.ac.jp:00005271", "sets": ["9"]}, "author_link": ["22096", "22099", "22098", "22097", "22100"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2014-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "564", "bibliographicPageStart": "561", "bibliographicVolumeNumber": "156", "bibliographic_titles": [{"bibliographic_title": "Acta Neurochirurgica"}]}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Here we describe a case of iliac artery injury during carotid artery stenting (CAS) treated by covered stent. A 74-year-old man underwent CAS for asymptomatic right carotid artery stenosis. Under local anesthesia, the right common femoral artery was punctured and an 8 Fr long sheath introducer was placed. However, the sheath kinked because the iliac artery was tortuous. We introduced the stylet to the sheath again and tried to extend the kinking. It failed, and the arterial dissection was identified at the lateral iliac artery. The kink was extended with triple coaxial system, i.e. guidewire, coaxial catheter, and a guiding catheter; CAS was performed with distal filter protection. Before removal of the sheath, the right iliac artery was examined, and extraversation of the contrast medium was observed. The balloon catheter was placed to the lesion and dilated for the hemostasis. However, it failed, and the covered stent was placed subsequently. Although blood tests revealed anemia and CT showed retroperitoneal hematoma after the treatment, further complication did not occur. Treatment with covered stent for the vessel injury was effective.", "subitem_description_type": "Abstract"}]}, "item_2_description_63": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "Acta Neurochirurgica, 156(3), pp.561-564; 2014", "subitem_description_type": "Other"}]}, "item_2_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Springer Wien"}]}, "item_2_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1007/s00701-013-1982-8", "subitem_relation_type_select": "DOI"}}]}, "item_2_rights_13": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "c 2013 Springer-Verlag Wien."}, {"subitem_rights": "The final publication is available at link.springer.com"}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "00016268", "subitem_source_identifier_type": "ISSN"}]}, "item_2_source_id_8": {"attribute_name": "EISSN", "attribute_value_mlt": [{"subitem_source_identifier": "09420940", "subitem_source_identifier_type": "ISSN"}]}, "item_2_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Hayashi, Kentaro"}], "nameIdentifiers": [{"nameIdentifier": "22096", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Horie, Nobutaka"}], "nameIdentifiers": [{"nameIdentifier": "22097", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakamoto, Ichiro"}], "nameIdentifiers": [{"nameIdentifier": "22098", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Morikawa, Minoru"}], "nameIdentifiers": [{"nameIdentifier": "22099", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nagata, Izumi"}], "nameIdentifiers": [{"nameIdentifier": "22100", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-12-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ActNeu156_561.pdf", "filesize": [{"value": "2.1 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 2100000.0, "url": {"label": "ActNeu156_561.pdf", "url": "https://nagasaki-u.repo.nii.ac.jp/record/5271/files/ActNeu156_561.pdf"}, "version_id": "88bcaa77-6a00-4485-ab98-0baae389051e"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Carotid artery stenting", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Complication", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Covered stent", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Iliac artery injury", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "A case of iliac artery injury treated by covered stent during carotid artery stenting", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "A case of iliac artery injury treated by covered stent during carotid artery stenting"}]}, "item_type_id": "2", "owner": "2", "path": ["9"], "permalink_uri": "http://hdl.handle.net/10069/34329", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-04-01"}, "publish_date": "2015-04-01", "publish_status": "0", "recid": "5271", "relation": {}, "relation_version_is_last": true, "title": ["A case of iliac artery injury treated by covered stent during carotid artery stenting"], "weko_shared_id": -1}
A case of iliac artery injury treated by covered stent during carotid artery stenting
http://hdl.handle.net/10069/34329
http://hdl.handle.net/10069/34329c55a09c8-419b-4e89-8aea-1496708da509
名前 / ファイル | ライセンス | アクション |
---|---|---|
ActNeu156_561.pdf (2.1 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-04-01 | |||||
タイトル | ||||||
タイトル | A case of iliac artery injury treated by covered stent during carotid artery stenting | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Carotid artery stenting | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Complication | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Covered stent | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Iliac artery injury | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Hayashi, Kentaro
× Hayashi, Kentaro× Horie, Nobutaka× Sakamoto, Ichiro× Morikawa, Minoru× Nagata, Izumi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Here we describe a case of iliac artery injury during carotid artery stenting (CAS) treated by covered stent. A 74-year-old man underwent CAS for asymptomatic right carotid artery stenosis. Under local anesthesia, the right common femoral artery was punctured and an 8 Fr long sheath introducer was placed. However, the sheath kinked because the iliac artery was tortuous. We introduced the stylet to the sheath again and tried to extend the kinking. It failed, and the arterial dissection was identified at the lateral iliac artery. The kink was extended with triple coaxial system, i.e. guidewire, coaxial catheter, and a guiding catheter; CAS was performed with distal filter protection. Before removal of the sheath, the right iliac artery was examined, and extraversation of the contrast medium was observed. The balloon catheter was placed to the lesion and dilated for the hemostasis. However, it failed, and the covered stent was placed subsequently. Although blood tests revealed anemia and CT showed retroperitoneal hematoma after the treatment, further complication did not occur. Treatment with covered stent for the vessel injury was effective. | |||||
書誌情報 |
Acta Neurochirurgica 巻 156, 号 3, p. 561-564, 発行日 2014-03 |
|||||
出版者 | ||||||
出版者 | Springer Wien | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 00016268 | |||||
EISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 09420940 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s00701-013-1982-8 | |||||
権利 | ||||||
権利情報 | c 2013 Springer-Verlag Wien. | |||||
権利 | ||||||
権利情報 | The final publication is available at link.springer.com | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Acta Neurochirurgica, 156(3), pp.561-564; 2014 |