WEKO3
アイテム
{"_buckets": {"deposit": "06cf73a8-1a01-4bad-8d73-f86f195cbf97"}, "_deposit": {"created_by": 2, "id": "5571", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "5571"}, "status": "published"}, "_oai": {"id": "oai:nagasaki-u.repo.nii.ac.jp:00005571", "sets": ["9"]}, "author_link": ["23650", "23648", "23649", "23651"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2014-06-17", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "6", "bibliographicPageEnd": "456", "bibliographicPageStart": "450", "bibliographicVolumeNumber": "54", "bibliographic_titles": [{"bibliographic_title": "Neurologia medico-chirurgica"}]}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "C-stopper coil (CSC) which are available for 0.018-inch inner diameter microcenter have been used for neurointervention such as transarterial embolization (TAE) of feeding artery. Although various shapes of pushable microcoils have been developed, microcoils are usually short to embolize the lesion and require lots of coils. The most specific feature of CSC is the extended length of 18 cm. To evaluate the usefulness of CSC, we reviewed our experience of CSC. Neurointervention using CSC was performed for 28 patients (31 treatments). Intervention procedures were TAE for dural arteriovenous fistula (AVF) (n = 15), transvenous embolization for dural AVF (n = 4), parent artery occlusion for cerebral aneurysm, dissection and carotidcavernous fistula (n = 8), TAE for epistaxis (n = 2), and preoperative embolization for tumor (n = 2). CSCs were deployed with push technique through microcatheter. CSCs were successfully placed into the lesion namely feeding artery, venous sinus, parent artery of aneurysm, or dissection. There were no major technical complications resulting in morbidity. Postoperative course was uneventful. No recanalization of the occluded vessel occurred during follow-up. Use of CSCs was safe and feasible for embolization of cerebrovascular lesion.", "subitem_description_type": "Abstract"}]}, "item_2_description_63": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "Neurologia medico-chirurgica, 54(6), pp.450-456; 2014", "subitem_description_type": "Other"}]}, "item_2_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本脳神経外科学会"}]}, "item_2_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.2176/nmc.oa.2013-0154", "subitem_relation_type_select": "DOI"}}]}, "item_2_rights_13": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "c 2014 by The Japan Neurosurgical Society"}, {"subitem_rights": "本文データは学会の許諾に基づきJ-STAGEから転載したものである。"}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "04708105", "subitem_source_identifier_type": "ISSN"}]}, "item_2_source_id_8": {"attribute_name": "EISSN", "attribute_value_mlt": [{"subitem_source_identifier": "13498029", "subitem_source_identifier_type": "ISSN"}]}, "item_2_text_62": {"attribute_name": "出版者別言語", "attribute_value_mlt": [{"subitem_text_value": "Japan Neurosurgical Society"}]}, "item_2_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Hayashi, Kentaro"}], "nameIdentifiers": [{"nameIdentifier": "23648", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Horie, Nobutaka"}], "nameIdentifiers": [{"nameIdentifier": "23649", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Morikawa, Minoru"}], "nameIdentifiers": [{"nameIdentifier": "23650", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nagata, Izumi"}], "nameIdentifiers": [{"nameIdentifier": "23651", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-12-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "NMC54_450.pdf", "filesize": [{"value": "931.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 931900.0, "url": {"label": "NMC54_450.pdf", "url": "https://nagasaki-u.repo.nii.ac.jp/record/5571/files/NMC54_450.pdf"}, "version_id": "0b1c3614-92eb-4fdf-bc0e-cba0a2a53384"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Coil", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Embolization", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Neurointervention", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Transarterial embolization", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Transvenous embolization", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Usefulness of C-stopper coil for neurointervention", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Usefulness of C-stopper coil for neurointervention"}]}, "item_type_id": "2", "owner": "2", "path": ["9"], "permalink_uri": "http://hdl.handle.net/10069/34652", "pubdate": {"attribute_name": "公開日", "attribute_value": "2014-08-11"}, "publish_date": "2014-08-11", "publish_status": "0", "recid": "5571", "relation": {}, "relation_version_is_last": true, "title": ["Usefulness of C-stopper coil for neurointervention"], "weko_shared_id": -1}
Usefulness of C-stopper coil for neurointervention
http://hdl.handle.net/10069/34652
http://hdl.handle.net/10069/34652fa8b8575-ac74-4144-9aca-3110894bff7f
名前 / ファイル | ライセンス | アクション |
---|---|---|
NMC54_450.pdf (931.9 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-08-11 | |||||
タイトル | ||||||
タイトル | Usefulness of C-stopper coil for neurointervention | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Coil | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Embolization | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Neurointervention | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Transarterial embolization | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Transvenous embolization | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Hayashi, Kentaro
× Hayashi, Kentaro× Horie, Nobutaka× Morikawa, Minoru× Nagata, Izumi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | C-stopper coil (CSC) which are available for 0.018-inch inner diameter microcenter have been used for neurointervention such as transarterial embolization (TAE) of feeding artery. Although various shapes of pushable microcoils have been developed, microcoils are usually short to embolize the lesion and require lots of coils. The most specific feature of CSC is the extended length of 18 cm. To evaluate the usefulness of CSC, we reviewed our experience of CSC. Neurointervention using CSC was performed for 28 patients (31 treatments). Intervention procedures were TAE for dural arteriovenous fistula (AVF) (n = 15), transvenous embolization for dural AVF (n = 4), parent artery occlusion for cerebral aneurysm, dissection and carotidcavernous fistula (n = 8), TAE for epistaxis (n = 2), and preoperative embolization for tumor (n = 2). CSCs were deployed with push technique through microcatheter. CSCs were successfully placed into the lesion namely feeding artery, venous sinus, parent artery of aneurysm, or dissection. There were no major technical complications resulting in morbidity. Postoperative course was uneventful. No recanalization of the occluded vessel occurred during follow-up. Use of CSCs was safe and feasible for embolization of cerebrovascular lesion. | |||||
書誌情報 |
Neurologia medico-chirurgica 巻 54, 号 6, p. 450-456, 発行日 2014-06-17 |
|||||
出版者 | ||||||
出版者 | 日本脳神経外科学会 | |||||
出版者別言語 | ||||||
Japan Neurosurgical Society | ||||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 04708105 | |||||
EISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 13498029 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.2176/nmc.oa.2013-0154 | |||||
権利 | ||||||
権利情報 | c 2014 by The Japan Neurosurgical Society | |||||
権利 | ||||||
権利情報 | 本文データは学会の許諾に基づきJ-STAGEから転載したものである。 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Neurologia medico-chirurgica, 54(6), pp.450-456; 2014 |