WEKO3
アイテム
{"_buckets": {"deposit": "81ae15d3-18f7-46db-aae9-0d6534e790fe"}, "_deposit": {"created_by": 2, "id": "10846", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "10846"}, "status": "published"}, "_oai": {"id": "oai:nagasaki-u.repo.nii.ac.jp:00010846", "sets": ["11"]}, "author_link": ["42617", "42619", "42621", "42618", "42620"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-06-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "62", "bibliographicPageStart": "59", "bibliographicVolumeNumber": "58", "bibliographic_titles": [{"bibliographic_title": "Journal of Nutritional Science and Vitaminology"}]}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A limited number of studies have been available to compare blood folate concentrations by the microbiological assay (MA) method with those using the chemiluminescent immunoassay (CLIA) method. We compared folate concentrations measured by Lactobacillus rhamnosus MA with those measured by CLIA (Access Immunoassay Systems) in human plasma/serum and erythrocytes pairs (n=35). The mean plasma folate by MA was significantly higher than that by CLIA (p\u003c0.0001), whereas the mean erythrocyte folate by MA was significantly lower than that by the CLIA method (p\u003c0.001). Plasma folate by MA significantly correlated with serum folate by CLIA (r=0.85, p\u003c0.001). Similarly, the correlation between erythrocyte folate measured by MA and CLIA methods was significant (r=0.87, p\u003c0.001). We conclude that folate concentrations obtained by CLIA are different from those obtained by MA, suggesting that it is undesirable for inter-laboratory comparisons when folate values are obtained by different methods. Although we evaluated only one CLIA method, we recommend careful evaluation of folate assay by each CLIA method before the use in clinical and research settings.", "subitem_description_type": "Abstract"}]}, "item_2_description_63": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "Journal of Nutritional Science and Vitaminology, 58(1), pp.59-62; 2012", "subitem_description_type": "Other"}]}, "item_2_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "学会誌刊行センター"}]}, "item_2_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.3177/jnsv.58.59", "subitem_relation_type_select": "DOI"}}]}, "item_2_rights_13": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "©学会誌刊行センター"}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "03014800", "subitem_source_identifier_type": "ISSN"}]}, "item_2_source_id_8": {"attribute_name": "EISSN", "attribute_value_mlt": [{"subitem_source_identifier": "18817742", "subitem_source_identifier_type": "ISSN"}]}, "item_2_text_62": {"attribute_name": "出版者別言語", "attribute_value_mlt": [{"subitem_text_value": "Center for Academic Publications Japan"}]}, "item_2_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Nakazato, Mio"}], "nameIdentifiers": [{"nameIdentifier": "42617", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Maeda, Takahiro"}], "nameIdentifiers": [{"nameIdentifier": "42618", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Emura, Kosuke"}], "nameIdentifiers": [{"nameIdentifier": "42619", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Maeda, Mayu"}], "nameIdentifiers": [{"nameIdentifier": "42620", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tamura, Tsunenobu"}], "nameIdentifiers": [{"nameIdentifier": "42621", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-12-22"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "JNSV58_59.pdf", "filesize": [{"value": "509.3 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 509300.0, "url": {"label": "JNSV58_59.pdf", "url": "https://nagasaki-u.repo.nii.ac.jp/record/10846/files/JNSV58_59.pdf"}, "version_id": "34174195-131f-402d-b7fd-aa2a4bbb6be7"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Chemiluminescent immunoassay", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Erythrocyte", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Folate", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Microbiological assay", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Plasma", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Blood Folate Concentrations Analyzed by Microbiological Assay and Chemiluminescent Immunoassay Methods", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Blood Folate Concentrations Analyzed by Microbiological Assay and Chemiluminescent Immunoassay Methods"}]}, "item_type_id": "2", "owner": "2", "path": ["11"], "permalink_uri": "http://hdl.handle.net/10069/29409", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-10-10"}, "publish_date": "2012-10-10", "publish_status": "0", "recid": "10846", "relation": {}, "relation_version_is_last": true, "title": ["Blood Folate Concentrations Analyzed by Microbiological Assay and Chemiluminescent Immunoassay Methods"], "weko_shared_id": -1}
Blood Folate Concentrations Analyzed by Microbiological Assay and Chemiluminescent Immunoassay Methods
http://hdl.handle.net/10069/29409
http://hdl.handle.net/10069/294094129733e-37fe-4042-b1e0-32047dd41b5d
名前 / ファイル | ライセンス | アクション |
---|---|---|
JNSV58_59.pdf (509.3 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-10-10 | |||||
タイトル | ||||||
タイトル | Blood Folate Concentrations Analyzed by Microbiological Assay and Chemiluminescent Immunoassay Methods | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Chemiluminescent immunoassay | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Erythrocyte | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Folate | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Microbiological assay | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Plasma | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Nakazato, Mio
× Nakazato, Mio× Maeda, Takahiro× Emura, Kosuke× Maeda, Mayu× Tamura, Tsunenobu |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A limited number of studies have been available to compare blood folate concentrations by the microbiological assay (MA) method with those using the chemiluminescent immunoassay (CLIA) method. We compared folate concentrations measured by Lactobacillus rhamnosus MA with those measured by CLIA (Access Immunoassay Systems) in human plasma/serum and erythrocytes pairs (n=35). The mean plasma folate by MA was significantly higher than that by CLIA (p<0.0001), whereas the mean erythrocyte folate by MA was significantly lower than that by the CLIA method (p<0.001). Plasma folate by MA significantly correlated with serum folate by CLIA (r=0.85, p<0.001). Similarly, the correlation between erythrocyte folate measured by MA and CLIA methods was significant (r=0.87, p<0.001). We conclude that folate concentrations obtained by CLIA are different from those obtained by MA, suggesting that it is undesirable for inter-laboratory comparisons when folate values are obtained by different methods. Although we evaluated only one CLIA method, we recommend careful evaluation of folate assay by each CLIA method before the use in clinical and research settings. | |||||
書誌情報 |
Journal of Nutritional Science and Vitaminology 巻 58, 号 1, p. 59-62, 発行日 2012-06-07 |
|||||
出版者 | ||||||
出版者 | 学会誌刊行センター | |||||
出版者別言語 | ||||||
Center for Academic Publications Japan | ||||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 03014800 | |||||
EISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 18817742 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.3177/jnsv.58.59 | |||||
権利 | ||||||
権利情報 | ©学会誌刊行センター | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Journal of Nutritional Science and Vitaminology, 58(1), pp.59-62; 2012 |