{"_buckets": {"deposit": "e6bc81ae-732e-416e-a956-532d3631395a"}, "_deposit": {"created_by": 2, "id": "13073", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "13073"}, "status": "published"}, "_oai": {"id": "oai:nagasaki-u.repo.nii.ac.jp:00013073", "sets": ["28"]}, "author_link": ["47585", "47587", "47588", "47586", "47584"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2010", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "453", "bibliographicPageStart": "446", "bibliographicVolumeNumber": "29", "bibliographic_titles": [{"bibliographic_title": "Dental Materials Journal"}]}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Chemical cleansing by denture cleansers is the first choice for denture plaque control of tissue conditioners. This study evaluated the influences of denture cleansers on the surface quality of tissue conditioners by determining surface roughness and porosity. Three tissue conditioners (Hydro-Cast, SR-Ivoseal, Visco-Gel) and 3 types of denture cleansers (Pika [enzyme type], Polident [neutral peroxide type with enzymes], Steradent [alkaline peroxide type]) were evaluated. Five specimens of each tissue conditioner/solution combination for each time period of immersion were prepared. The surface roughness of dental stone casts made from the tissue conditioners was evaluated using a profilometer. The surface quality of Hydro-Cast and Visco-Gel tended to be most deteriorated by the alkaline peroxide cleanser. The enzyme type of denture cleansers is most suitable for tissue conditioners in terms of surface quality. The suitable period for application of the enzyme cleansers would range from 3 to 7 days.", "subitem_description_type": "Abstract"}]}, "item_2_description_63": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "Dental Materials Journal, 29(4), pp.446-453; 2010", "subitem_description_type": "Other"}]}, "item_2_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "The Japanese Society for Dental Materials and Devices"}]}, "item_2_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.4012/dmj.2009-135", "subitem_relation_type_select": "DOI"}}]}, "item_2_rights_13": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright (c) 2010 The Japanese Society for Dental Materials and Devices"}]}, "item_2_source_id_10": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA10443149", "subitem_source_identifier_type": "NCID"}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "02874547", "subitem_source_identifier_type": "ISSN"}]}, "item_2_source_id_8": {"attribute_name": "EISSN", "attribute_value_mlt": [{"subitem_source_identifier": "18811361", "subitem_source_identifier_type": "ISSN"}]}, "item_2_text_62": {"attribute_name": "出版者別言語", "attribute_value_mlt": [{"subitem_text_value": "日本歯科理工学会"}]}, "item_2_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Murata, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "47584", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Chimori, Hironori"}], "nameIdentifiers": [{"nameIdentifier": "47585", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hong, Guang"}], "nameIdentifiers": [{"nameIdentifier": "47586", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hamada, Taizo"}], "nameIdentifiers": [{"nameIdentifier": "47587", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nikawa, Hiroki"}], "nameIdentifiers": [{"nameIdentifier": "47588", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-12-22"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "DMJ29_446.pdf", "filesize": [{"value": "1.8 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1800000.0, "url": {"label": "DMJ29_446.pdf", "url": "https://nagasaki-u.repo.nii.ac.jp/record/13073/files/DMJ29_446.pdf"}, "version_id": "c5e3f782-90a0-42aa-8635-bdedb1aafb58"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Denture cleansers", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Surface conditions", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Tissue conditioners", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Compatibility of tissue conditioners and denture cleansers: Influence on surface conditions", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Compatibility of tissue conditioners and denture cleansers: Influence on surface conditions"}]}, "item_type_id": "2", "owner": "2", "path": ["28"], "permalink_uri": "http://hdl.handle.net/10069/25097", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-05-19"}, "publish_date": "2011-05-19", "publish_status": "0", "recid": "13073", "relation": {}, "relation_version_is_last": true, "title": ["Compatibility of tissue conditioners and denture cleansers: Influence on surface conditions"], "weko_shared_id": 2}
Compatibility of tissue conditioners and denture cleansers: Influence on surface conditions
http://hdl.handle.net/10069/25097
http://hdl.handle.net/10069/2509728302792-7092-4ea7-aef5-f00ed5e62909
名前 / ファイル | ライセンス | アクション |
---|---|---|
DMJ29_446.pdf (1.8 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-05-19 | |||||
タイトル | ||||||
タイトル | Compatibility of tissue conditioners and denture cleansers: Influence on surface conditions | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Denture cleansers | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Surface conditions | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Tissue conditioners | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Murata, Hiroshi
× Murata, Hiroshi× Chimori, Hironori× Hong, Guang× Hamada, Taizo× Nikawa, Hiroki |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Chemical cleansing by denture cleansers is the first choice for denture plaque control of tissue conditioners. This study evaluated the influences of denture cleansers on the surface quality of tissue conditioners by determining surface roughness and porosity. Three tissue conditioners (Hydro-Cast, SR-Ivoseal, Visco-Gel) and 3 types of denture cleansers (Pika [enzyme type], Polident [neutral peroxide type with enzymes], Steradent [alkaline peroxide type]) were evaluated. Five specimens of each tissue conditioner/solution combination for each time period of immersion were prepared. The surface roughness of dental stone casts made from the tissue conditioners was evaluated using a profilometer. The surface quality of Hydro-Cast and Visco-Gel tended to be most deteriorated by the alkaline peroxide cleanser. The enzyme type of denture cleansers is most suitable for tissue conditioners in terms of surface quality. The suitable period for application of the enzyme cleansers would range from 3 to 7 days. | |||||
書誌情報 |
Dental Materials Journal 巻 29, 号 4, p. 446-453, 発行日 2010 |
|||||
出版者 | ||||||
出版者 | The Japanese Society for Dental Materials and Devices | |||||
出版者別言語 | ||||||
日本歯科理工学会 | ||||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 02874547 | |||||
EISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 18811361 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA10443149 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.4012/dmj.2009-135 | |||||
権利 | ||||||
権利情報 | Copyright (c) 2010 The Japanese Society for Dental Materials and Devices | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Dental Materials Journal, 29(4), pp.446-453; 2010 |