WEKO3
アイテム
{"_buckets": {"deposit": "980a2471-0376-4680-a096-9eeb7b444ede"}, "_deposit": {"created_by": 2, "id": "13074", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "13074"}, "status": "published"}, "_oai": {"id": "oai:nagasaki-u.repo.nii.ac.jp:00013074", "sets": ["28"]}, "author_link": ["47592", "47594", "47591", "47593", "47590", "47589"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2010", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "380", "bibliographicPageStart": "374", "bibliographicVolumeNumber": "29", "bibliographic_titles": [{"bibliographic_title": "Dental Materials Journal"}]}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The purpose of this study was to determine the effect of PMMA polymer on dynamic viscoelasticity and plasticizer leachability of PEMA-based tissue conditioners. One PEMA polymer and one PMMA polymer were used in powder form with four formulations. The combination of 80 wt% ATBC, 15 wt% BPBG and 5 wt% ethyl alcohol was used as the liquid phase. The dynamic viscoelasticity and plasticizer leaching of each specimen were measured after 0, 1, 3, 7, and 14 days of immersion (37°C distilled water) using DMA and HPLC. A significant difference was found among the materials in the dynamic viscoelasticity and leaching of plasticizer. The materials containing 10 wt% PMMA showed the most stable dynamic viscoelasticity, and showed the lowest leaching of plasticizer. The results suggest that the addition of the PMMA polymer to the powder of a tissue conditioner can improve the durability of the PEMA-based tissue conditioner.", "subitem_description_type": "Abstract"}]}, "item_2_description_63": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "Dental Materials Journal, 29(4), pp.374-380; 2010", "subitem_description_type": "Other"}]}, "item_2_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "The Japanese Society for Dental Materials and Devices"}]}, "item_2_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.4012/dmj.2009-134", "subitem_relation_type_select": "DOI"}}]}, "item_2_rights_13": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright (c) 2010 The Japanese Society for Dental Materials and Devices"}]}, "item_2_source_id_10": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA10443149", "subitem_source_identifier_type": "NCID"}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "02874547", "subitem_source_identifier_type": "ISSN"}]}, "item_2_source_id_8": {"attribute_name": "EISSN", "attribute_value_mlt": [{"subitem_source_identifier": "18811361", "subitem_source_identifier_type": "ISSN"}]}, "item_2_text_62": {"attribute_name": "出版者別言語", "attribute_value_mlt": [{"subitem_text_value": "日本歯科理工学会"}]}, "item_2_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Hong, Guang"}], "nameIdentifiers": [{"nameIdentifier": "47589", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Maeda, Takeshi"}], "nameIdentifiers": [{"nameIdentifier": "47590", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Li, YingAi"}], "nameIdentifiers": [{"nameIdentifier": "47591", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sadamori, Shinsuke"}], "nameIdentifiers": [{"nameIdentifier": "47592", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hamada, Taizo"}], "nameIdentifiers": [{"nameIdentifier": "47593", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Murata, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "47594", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-12-22"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "DMJ29_374.pdf", "filesize": [{"value": "1.4 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1400000.0, "url": {"label": "DMJ29_374.pdf", "url": "https://nagasaki-u.repo.nii.ac.jp/record/13074/files/DMJ29_374.pdf"}, "version_id": "4d73dcf9-945d-4700-9030-b8a06b66abe2"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Dynamic viscoelasticity", "subitem_subject_scheme": "Other"}, {"subitem_subject": "HPLC", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Tissue conditioner", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Effect of PMMA polymer on the dynamic viscoelasticity and plasticizer leachability of PEMA-based tissue conditioners", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Effect of PMMA polymer on the dynamic viscoelasticity and plasticizer leachability of PEMA-based tissue conditioners"}]}, "item_type_id": "2", "owner": "2", "path": ["28"], "permalink_uri": "http://hdl.handle.net/10069/25098", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-05-19"}, "publish_date": "2011-05-19", "publish_status": "0", "recid": "13074", "relation": {}, "relation_version_is_last": true, "title": ["Effect of PMMA polymer on the dynamic viscoelasticity and plasticizer leachability of PEMA-based tissue conditioners"], "weko_shared_id": 2}
Effect of PMMA polymer on the dynamic viscoelasticity and plasticizer leachability of PEMA-based tissue conditioners
http://hdl.handle.net/10069/25098
http://hdl.handle.net/10069/25098d15c5e47-135f-4600-9d12-38ef70a4cace
名前 / ファイル | ライセンス | アクション |
---|---|---|
DMJ29_374.pdf (1.4 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-05-19 | |||||
タイトル | ||||||
タイトル | Effect of PMMA polymer on the dynamic viscoelasticity and plasticizer leachability of PEMA-based tissue conditioners | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Dynamic viscoelasticity | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | HPLC | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Tissue conditioner | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Hong, Guang
× Hong, Guang× Maeda, Takeshi× Li, YingAi× Sadamori, Shinsuke× Hamada, Taizo× Murata, Hiroshi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The purpose of this study was to determine the effect of PMMA polymer on dynamic viscoelasticity and plasticizer leachability of PEMA-based tissue conditioners. One PEMA polymer and one PMMA polymer were used in powder form with four formulations. The combination of 80 wt% ATBC, 15 wt% BPBG and 5 wt% ethyl alcohol was used as the liquid phase. The dynamic viscoelasticity and plasticizer leaching of each specimen were measured after 0, 1, 3, 7, and 14 days of immersion (37°C distilled water) using DMA and HPLC. A significant difference was found among the materials in the dynamic viscoelasticity and leaching of plasticizer. The materials containing 10 wt% PMMA showed the most stable dynamic viscoelasticity, and showed the lowest leaching of plasticizer. The results suggest that the addition of the PMMA polymer to the powder of a tissue conditioner can improve the durability of the PEMA-based tissue conditioner. | |||||
書誌情報 |
Dental Materials Journal 巻 29, 号 4, p. 374-380, 発行日 2010 |
|||||
出版者 | ||||||
出版者 | The Japanese Society for Dental Materials and Devices | |||||
出版者別言語 | ||||||
日本歯科理工学会 | ||||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 02874547 | |||||
EISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 18811361 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA10443149 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.4012/dmj.2009-134 | |||||
権利 | ||||||
権利情報 | Copyright (c) 2010 The Japanese Society for Dental Materials and Devices | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Dental Materials Journal, 29(4), pp.374-380; 2010 |