WEKO3
アイテム
{"_buckets": {"deposit": "5520b51a-a6b5-4bf7-8ec6-f523fc6d5dd0"}, "_deposit": {"created_by": 2, "id": "1605", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "1605"}, "status": "published"}, "_oai": {"id": "oai:nagasaki-u.repo.nii.ac.jp:00001605", "sets": ["21"]}, "author_link": ["7742", "7741", "7743"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2016-04-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "239", "bibliographicPageStart": "231", "bibliographicVolumeNumber": "10", "bibliographic_titles": [{"bibliographic_title": "IET Electric Power Applications"}]}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Fractional-slot winding configurations have attracted much attention due to the availability of concentrated windings and low cogging torque in permanent magnet brushless motors. For the design of the winding configurations, many design parameters must be determined. The winding factor provides a useful index for the optimal design. However, no general expressions of the winding factor have been derived for all the winding configurations. This study performs the general formulation of the winding factor for the fractional-slot concentrated windings. The winding factor is redefined for stator windings without any information of the numbers of poles. For given stator windings, the optimal numbers of poles are determined from the obtained winding factors. The design strategy for the winding configurations is validated through a finite element method analysis.", "subitem_description_type": "Abstract"}]}, "item_2_description_63": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "IET Electric Power Applications, 10(4), pp.231-239; 2016", "subitem_description_type": "Other"}]}, "item_2_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "The Institution of Engineering and Technology"}]}, "item_2_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1049/iet-epa.2015.0092", "subitem_relation_type_select": "DOI"}}]}, "item_2_rights_13": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "c The Institution of Engineering and Technology"}, {"subitem_rights": "This paper is a postprint of a paper submitted to and accepted for publication in IET Electric Power Applications and is subject to Institution of Engineering and Technology Copyright. The copy of record is available at the IET Digital Library."}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "17518660", "subitem_source_identifier_type": "ISSN"}]}, "item_2_source_id_8": {"attribute_name": "EISSN", "attribute_value_mlt": [{"subitem_source_identifier": "17518679", "subitem_source_identifier_type": "ISSN"}]}, "item_2_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yokoi, Yuichi"}], "nameIdentifiers": [{"nameIdentifier": "7741", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Higuchi, Tsuyoshi"}], "nameIdentifiers": [{"nameIdentifier": "7742", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miyamoto, Yasuhiro"}], "nameIdentifiers": [{"nameIdentifier": "7743", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-12-18"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "IET-EPA10_231.pdf", "filesize": [{"value": "2.5 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 2500000.0, "url": {"label": "IET-EPA10_231.pdf", "url": "https://nagasaki-u.repo.nii.ac.jp/record/1605/files/IET-EPA10_231.pdf"}, "version_id": "538b0bd6-f09b-44ae-a73a-f9381baac7bd"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "General formulation of winding factor for fractional-slot concentrated winding design", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "General formulation of winding factor for fractional-slot concentrated winding design"}]}, "item_type_id": "2", "owner": "2", "path": ["21"], "permalink_uri": "http://hdl.handle.net/10069/38875", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-03-04"}, "publish_date": "2019-03-04", "publish_status": "0", "recid": "1605", "relation": {}, "relation_version_is_last": true, "title": ["General formulation of winding factor for fractional-slot concentrated winding design"], "weko_shared_id": -1}
General formulation of winding factor for fractional-slot concentrated winding design
http://hdl.handle.net/10069/38875
http://hdl.handle.net/10069/38875e744488e-c24c-4820-8f42-434728ff6861
名前 / ファイル | ライセンス | アクション |
---|---|---|
IET-EPA10_231.pdf (2.5 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-03-04 | |||||
タイトル | ||||||
タイトル | General formulation of winding factor for fractional-slot concentrated winding design | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Yokoi, Yuichi
× Yokoi, Yuichi× Higuchi, Tsuyoshi× Miyamoto, Yasuhiro |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Fractional-slot winding configurations have attracted much attention due to the availability of concentrated windings and low cogging torque in permanent magnet brushless motors. For the design of the winding configurations, many design parameters must be determined. The winding factor provides a useful index for the optimal design. However, no general expressions of the winding factor have been derived for all the winding configurations. This study performs the general formulation of the winding factor for the fractional-slot concentrated windings. The winding factor is redefined for stator windings without any information of the numbers of poles. For given stator windings, the optimal numbers of poles are determined from the obtained winding factors. The design strategy for the winding configurations is validated through a finite element method analysis. | |||||
書誌情報 |
IET Electric Power Applications 巻 10, 号 4, p. 231-239, 発行日 2016-04-01 |
|||||
出版者 | ||||||
出版者 | The Institution of Engineering and Technology | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 17518660 | |||||
EISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 17518679 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1049/iet-epa.2015.0092 | |||||
権利 | ||||||
権利情報 | c The Institution of Engineering and Technology | |||||
権利 | ||||||
権利情報 | This paper is a postprint of a paper submitted to and accepted for publication in IET Electric Power Applications and is subject to Institution of Engineering and Technology Copyright. The copy of record is available at the IET Digital Library. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | IET Electric Power Applications, 10(4), pp.231-239; 2016 |