{"_buckets": {"deposit": "bb6888d6-b272-49ea-b462-45eade200e10"}, "_deposit": {"created_by": 2, "id": "17916", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "17916"}, "status": "published"}, "_oai": {"id": "oai:nagasaki-u.repo.nii.ac.jp:00017916", "sets": ["9"]}, "author_link": ["71001", "71006", "71005", "71004", "71003", "71000", "71002"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009-11", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "5", "bibliographicPageEnd": "537", "bibliographicPageStart": "532", "bibliographicVolumeNumber": "72", "bibliographic_titles": [{"bibliographic_title": "Surgical Neurology"}]}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Background: Carotid artery stenting (CAS) in high-surgical-risk patients is considered as an effective alternative to carotid endarterectomy. Since the occurrence of distal embolization with CAS is still major concern, embolus protection device is usually employed during the procedure. We developed a technique for observation of embolus protection filter and evaluate the debris or thrombus microscopically, and the pathological findings were compared with preoperative imaging studies.\nPatients and Methods: After completing CAS, filter membrane was stained with hematoxylin \u0026 eosin (HE) solution and removed from filer strut. Mounting onto a glass slide, filter was evaluated under microscope. Plaque debris and appearance of filter membrane were evaluated and the covered area was measured. The pathological findings were compared with preoperative imaging studies.\nResults: Microscopical observation of the slide revealed atheromatous debris as well as thrombotic material to the filter membrane. HE stain facilitates the characterization of the debris composition, namely thrombotic debris, calicified debris, organized debris, fibrous debris, lipid-rich debris. The subtypes of debris were consistent with preoperative imaging studies. Thus. in cases of intraprocedural flow impairment, more than 50% of filter area was covered with debris or thrombotic material.\nConclusion: Carotid plaque debris captured during carotid stenting with protection filter can be visualized with HE stain on the glass side. This simple method allows us to better understand plaque debris and appearance of embolus protection filter.", "subitem_description_type": "Abstract"}]}, "item_2_description_63": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "Surgical Neurology, 72(5), pp.532-537; 2009", "subitem_description_type": "Other"}]}, "item_2_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier BV"}]}, "item_2_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.surneu.2008.12.011", "subitem_relation_type_select": "DOI"}}]}, "item_2_rights_13": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "c Copyright 2009 Elsevier B.V., All rights reserved."}]}, "item_2_source_id_10": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA0085395X", "subitem_source_identifier_type": "NCID"}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "00903019", "subitem_source_identifier_type": "ISSN"}]}, "item_2_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Hayashi, Kentaro"}], "nameIdentifiers": [{"nameIdentifier": "71000", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kitagawa, Naoki"}], "nameIdentifiers": [{"nameIdentifier": "71001", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Morikawa, Minoru"}], "nameIdentifiers": [{"nameIdentifier": "71002", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hiu, Takeshi"}], "nameIdentifiers": [{"nameIdentifier": "71003", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Morofuji, Yoichi"}], "nameIdentifiers": [{"nameIdentifier": "71004", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Suyama, Kazuhiko"}], "nameIdentifiers": [{"nameIdentifier": "71005", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nagata, Izumi"}], "nameIdentifiers": [{"nameIdentifier": "71006", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-12-23"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "SurNeu72_532.pdf", "filesize": [{"value": "1.2 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1200000.0, "url": {"label": "SurNeu72_532.pdf", "url": "https://nagasaki-u.repo.nii.ac.jp/record/17916/files/SurNeu72_532.pdf"}, "version_id": "2947984b-e6fb-468a-ade4-0b35e7374fc8"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "carotid plaque", "subitem_subject_scheme": "Other"}, {"subitem_subject": "stent", "subitem_subject_scheme": "Other"}, {"subitem_subject": "microscopical observation", "subitem_subject_scheme": "Other"}, {"subitem_subject": "hematoxylin-eosin stain", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Observation of the embolus protection filter for carotid artery stenting", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Observation of the embolus protection filter for carotid artery stenting"}]}, "item_type_id": "2", "owner": "2", "path": ["9"], "permalink_uri": "http://hdl.handle.net/10069/21787", "pubdate": {"attribute_name": "公開日", "attribute_value": "2009-05-01"}, "publish_date": "2009-05-01", "publish_status": "0", "recid": "17916", "relation": {}, "relation_version_is_last": true, "title": ["Observation of the embolus protection filter for carotid artery stenting"], "weko_shared_id": -1}
Observation of the embolus protection filter for carotid artery stenting
http://hdl.handle.net/10069/21787
http://hdl.handle.net/10069/21787c5af6641-ac11-4669-aeae-48eb824903b1
名前 / ファイル | ライセンス | アクション |
---|---|---|
SurNeu72_532.pdf (1.2 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-05-01 | |||||
タイトル | ||||||
タイトル | Observation of the embolus protection filter for carotid artery stenting | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | carotid plaque | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | stent | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | microscopical observation | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | hematoxylin-eosin stain | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Hayashi, Kentaro
× Hayashi, Kentaro× Kitagawa, Naoki× Morikawa, Minoru× Hiu, Takeshi× Morofuji, Yoichi× Suyama, Kazuhiko× Nagata, Izumi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Background: Carotid artery stenting (CAS) in high-surgical-risk patients is considered as an effective alternative to carotid endarterectomy. Since the occurrence of distal embolization with CAS is still major concern, embolus protection device is usually employed during the procedure. We developed a technique for observation of embolus protection filter and evaluate the debris or thrombus microscopically, and the pathological findings were compared with preoperative imaging studies. Patients and Methods: After completing CAS, filter membrane was stained with hematoxylin & eosin (HE) solution and removed from filer strut. Mounting onto a glass slide, filter was evaluated under microscope. Plaque debris and appearance of filter membrane were evaluated and the covered area was measured. The pathological findings were compared with preoperative imaging studies. Results: Microscopical observation of the slide revealed atheromatous debris as well as thrombotic material to the filter membrane. HE stain facilitates the characterization of the debris composition, namely thrombotic debris, calicified debris, organized debris, fibrous debris, lipid-rich debris. The subtypes of debris were consistent with preoperative imaging studies. Thus. in cases of intraprocedural flow impairment, more than 50% of filter area was covered with debris or thrombotic material. Conclusion: Carotid plaque debris captured during carotid stenting with protection filter can be visualized with HE stain on the glass side. This simple method allows us to better understand plaque debris and appearance of embolus protection filter. |
|||||
書誌情報 |
Surgical Neurology 巻 72, 号 5, p. 532-537, 発行日 2009-11 |
|||||
出版者 | ||||||
出版者 | Elsevier BV | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 00903019 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA0085395X | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.surneu.2008.12.011 | |||||
権利 | ||||||
権利情報 | c Copyright 2009 Elsevier B.V., All rights reserved. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Surgical Neurology, 72(5), pp.532-537; 2009 |