WEKO3
アイテム
{"_buckets": {"deposit": "10c63f75-82c0-40b4-a1d6-151fba88a146"}, "_deposit": {"created_by": 2, "id": "18023", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "18023"}, "status": "published"}, "_oai": {"id": "oai:nagasaki-u.repo.nii.ac.jp:00018023", "sets": ["21"]}, "author_link": ["71608", "71607", "71605", "71606"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009-06", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "569", "bibliographicPageStart": "563", "bibliographicVolumeNumber": "139", "bibliographic_titles": [{"bibliographic_title": "Sensors and Actuators B: Chemical"}]}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Macrostructural effects of an auxiliary electrode on the CO2 gas sensing properties of NASICON (Na3Zr2Si2PO12) solid-electrolyte sensors were investigated. The sensor with a porous Li2CO3?BaCO3-based auxiliary layer (mp-Sensor), which was prepared by utilizing constituent metal acetates and polymethylmethacrylate microspheres as a template, showed faster CO2 response and recovery and smaller cross-response against humidity changes than those obtained with a dense auxiliary layer without pores (d-Sensor). The magnitude of CO2 response of mp-Sensor was slightly larger than the theoretical one, probably due to the existence of impurities which might have reacted with CO2 in the auxiliary layer. On the other hand, c-Sensor with a thicker and dense auxiliary layer, which was prepared by commercially available carbonates, showed smaller CO2 response and larger cross-response to humidity than mp-Sensor and d-Sensor. Thus, the use of the porous auxiliary layer prepared by constituent metal acetates was confirmed to be effective for improving the CO2 sensing properties along with the large CO2 response and small cross-response to humidity.", "subitem_description_type": "Abstract"}]}, "item_2_description_63": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "Sensors and Actuators. B: Chemical, 139(2), pp.563-569; 2009", "subitem_description_type": "Other"}]}, "item_2_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier B.V."}]}, "item_2_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.snb.2009.03.038", "subitem_relation_type_select": "DOI"}}]}, "item_2_rights_13": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright c 2009 Elsevier B.V. All rights reserved."}]}, "item_2_source_id_10": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA1078104X", "subitem_source_identifier_type": "NCID"}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "09254005", "subitem_source_identifier_type": "ISSN"}]}, "item_2_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Morio, Masataka"}], "nameIdentifiers": [{"nameIdentifier": "71605", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hyodo, Takeo"}], "nameIdentifiers": [{"nameIdentifier": "71606", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shimizu, Yasuhiro"}], "nameIdentifiers": [{"nameIdentifier": "71607", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Egashira, Makoto"}], "nameIdentifiers": [{"nameIdentifier": "71608", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-12-23"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "SABC139_563.pdf", "filesize": [{"value": "3.4 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 3400000.0, "url": {"label": "SABC139_563.pdf", "url": "https://nagasaki-u.repo.nii.ac.jp/record/18023/files/SABC139_563.pdf"}, "version_id": "aac5507f-2ec6-4265-bb98-a0a418f4d8c5"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "CO2 gas sensor", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Solid electrolyte", "subitem_subject_scheme": "Other"}, {"subitem_subject": "NASICON", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Carbonate", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Macropore", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Humidity", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Effect of macrostructural control of an auxiliary layer on the CO2 sensing properties of NASICON-based gas sensors", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Effect of macrostructural control of an auxiliary layer on the CO2 sensing properties of NASICON-based gas sensors"}]}, "item_type_id": "2", "owner": "2", "path": ["21"], "permalink_uri": "http://hdl.handle.net/10069/21900", "pubdate": {"attribute_name": "公開日", "attribute_value": "2009-05-20"}, "publish_date": "2009-05-20", "publish_status": "0", "recid": "18023", "relation": {}, "relation_version_is_last": true, "title": ["Effect of macrostructural control of an auxiliary layer on the CO2 sensing properties of NASICON-based gas sensors"], "weko_shared_id": -1}
Effect of macrostructural control of an auxiliary layer on the CO2 sensing properties of NASICON-based gas sensors
http://hdl.handle.net/10069/21900
http://hdl.handle.net/10069/21900fcf72d5e-5324-4753-9570-945c0be724c6
名前 / ファイル | ライセンス | アクション |
---|---|---|
SABC139_563.pdf (3.4 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-05-20 | |||||
タイトル | ||||||
タイトル | Effect of macrostructural control of an auxiliary layer on the CO2 sensing properties of NASICON-based gas sensors | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | CO2 gas sensor | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Solid electrolyte | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | NASICON | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Carbonate | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Macropore | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Humidity | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Morio, Masataka
× Morio, Masataka× Hyodo, Takeo× Shimizu, Yasuhiro× Egashira, Makoto |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Macrostructural effects of an auxiliary electrode on the CO2 gas sensing properties of NASICON (Na3Zr2Si2PO12) solid-electrolyte sensors were investigated. The sensor with a porous Li2CO3?BaCO3-based auxiliary layer (mp-Sensor), which was prepared by utilizing constituent metal acetates and polymethylmethacrylate microspheres as a template, showed faster CO2 response and recovery and smaller cross-response against humidity changes than those obtained with a dense auxiliary layer without pores (d-Sensor). The magnitude of CO2 response of mp-Sensor was slightly larger than the theoretical one, probably due to the existence of impurities which might have reacted with CO2 in the auxiliary layer. On the other hand, c-Sensor with a thicker and dense auxiliary layer, which was prepared by commercially available carbonates, showed smaller CO2 response and larger cross-response to humidity than mp-Sensor and d-Sensor. Thus, the use of the porous auxiliary layer prepared by constituent metal acetates was confirmed to be effective for improving the CO2 sensing properties along with the large CO2 response and small cross-response to humidity. | |||||
書誌情報 |
Sensors and Actuators B: Chemical 巻 139, 号 2, p. 563-569, 発行日 2009-06 |
|||||
出版者 | ||||||
出版者 | Elsevier B.V. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 09254005 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA1078104X | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.snb.2009.03.038 | |||||
権利 | ||||||
権利情報 | Copyright c 2009 Elsevier B.V. All rights reserved. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Sensors and Actuators. B: Chemical, 139(2), pp.563-569; 2009 |