WEKO3
アイテム
{"_buckets": {"deposit": "e9c98ef6-68bb-4f18-87c8-b38a67cf3316"}, "_deposit": {"created_by": 2, "id": "19000", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "19000"}, "status": "published"}, "_oai": {"id": "oai:nagasaki-u.repo.nii.ac.jp:00019000", "sets": ["65"]}, "author_link": ["77974", "77978", "77973", "77977", "77975", "77976"], "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-09", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "153", "bibliographicPageStart": "148", "bibliographic_titles": [{"bibliographic_title": "2008 13th International Power Electronics and Motion Control Conference (EPE-PEMC 2008)"}]}]}, "item_9_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "This paper mentions the static characteristics of pulse-link DC-AC converter for fuel cells, and considers the input current-ripple reduction method. Fuel cells have weakness about current-ripple because the chemical reaction time is much slower than commercial frequency. Therefore, the input current-ripple reduction is essential factor in the DC-AC converter for fuel cells applications. Input current-ripple from fuel cells gives damage the fuel consumption and life time. The conventional DC-AC converter has large smoothing capacitor between boost converter stage and PWM converter stage, in order to reduce input current-ripple. That capacitor prevents from reduction the size of unit. Authors have proposed a novel topology called as pulse-link DC-AC converter. The pulselink DC-AC converter topology is no need to insert large capacitor. Furthermore, the series-connected LC circuit between two stages connected in parallel works as ripple canceling. This paper shows the mechanism of currentripple reduction.", "subitem_description_type": "Abstract"}]}, "item_9_description_5": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "2008 13th International Power Electronics and Motion Control Conference, EPE-PEMC 2008; Poznan; 1 September 2008 through 3 September 2008", "subitem_description_type": "Other"}]}, "item_9_description_63": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "EPE-PEMC 2008, pp.148-153", "subitem_description_type": "Other"}]}, "item_9_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Institute of Electrical and Electronics Engineers"}]}, "item_9_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1109/EPEPEMC.2008.4635259", "subitem_relation_type_select": "DOI"}}]}, "item_9_relation_9": {"attribute_name": "ISBN", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "978-1-4244-1741-4", "subitem_relation_type_select": "ISBN"}}]}, "item_9_rights_13": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "(c)2008 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE."}]}, "item_9_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Fukushima, Kentaro"}], "nameIdentifiers": [{"nameIdentifier": "77973", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ninomiya, Tamotsu"}], "nameIdentifiers": [{"nameIdentifier": "77974", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shoyama, Masahito"}], "nameIdentifiers": [{"nameIdentifier": "77975", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Norigoe, Isami"}], "nameIdentifiers": [{"nameIdentifier": "77976", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Harada, Yosuke"}], "nameIdentifiers": [{"nameIdentifier": "77977", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsukakoshi, Kenta"}], "nameIdentifiers": [{"nameIdentifier": "77978", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-12-23"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "EPE-PEMC2008_148.pdf", "filesize": [{"value": "261.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 261600.00000000003, "url": {"label": "EPE-PEMC2008_148.pdf", "url": "https://nagasaki-u.repo.nii.ac.jp/record/19000/files/EPE-PEMC2008_148.pdf"}, "version_id": "f2472d4c-37bf-48dc-902d-06fa0d9deaba"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "Consideration for input current-ripple of pulse-link DC-AC converter for fuel cells", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Consideration for input current-ripple of pulse-link DC-AC converter for fuel cells"}]}, "item_type_id": "9", "owner": "2", "path": ["65"], "permalink_uri": "http://hdl.handle.net/10069/20828", "pubdate": {"attribute_name": "公開日", "attribute_value": "2008-12-17"}, "publish_date": "2008-12-17", "publish_status": "0", "recid": "19000", "relation": {}, "relation_version_is_last": true, "title": ["Consideration for input current-ripple of pulse-link DC-AC converter for fuel cells"], "weko_shared_id": -1}
Consideration for input current-ripple of pulse-link DC-AC converter for fuel cells
http://hdl.handle.net/10069/20828
http://hdl.handle.net/10069/20828cd9e1d04-6edf-488a-bd7e-5eb488ce5204
名前 / ファイル | ライセンス | アクション |
---|---|---|
EPE-PEMC2008_148.pdf (261.6 kB)
|
|
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-12-17 | |||||
タイトル | ||||||
タイトル | Consideration for input current-ripple of pulse-link DC-AC converter for fuel cells | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
著者 |
Fukushima, Kentaro
× Fukushima, Kentaro× Ninomiya, Tamotsu× Shoyama, Masahito× Norigoe, Isami× Harada, Yosuke× Tsukakoshi, Kenta |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | This paper mentions the static characteristics of pulse-link DC-AC converter for fuel cells, and considers the input current-ripple reduction method. Fuel cells have weakness about current-ripple because the chemical reaction time is much slower than commercial frequency. Therefore, the input current-ripple reduction is essential factor in the DC-AC converter for fuel cells applications. Input current-ripple from fuel cells gives damage the fuel consumption and life time. The conventional DC-AC converter has large smoothing capacitor between boost converter stage and PWM converter stage, in order to reduce input current-ripple. That capacitor prevents from reduction the size of unit. Authors have proposed a novel topology called as pulse-link DC-AC converter. The pulselink DC-AC converter topology is no need to insert large capacitor. Furthermore, the series-connected LC circuit between two stages connected in parallel works as ripple canceling. This paper shows the mechanism of currentripple reduction. | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 2008 13th International Power Electronics and Motion Control Conference, EPE-PEMC 2008; Poznan; 1 September 2008 through 3 September 2008 | |||||
書誌情報 |
2008 13th International Power Electronics and Motion Control Conference (EPE-PEMC 2008) p. 148-153, 発行日 2008-09 |
|||||
ISBN | ||||||
識別子タイプ | ISBN | |||||
関連識別子 | 978-1-4244-1741-4 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1109/EPEPEMC.2008.4635259 | |||||
権利 | ||||||
権利情報 | (c)2008 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE. | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | Institute of Electrical and Electronics Engineers | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | EPE-PEMC 2008, pp.148-153 |