{"_buckets": {"deposit": "f151c372-ed6f-4879-ab65-356ae71d3851"}, "_deposit": {"created_by": 2, "id": "23141", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "23141"}, "status": "published"}, "_oai": {"id": "oai:nagasaki-u.repo.nii.ac.jp:00023141", "sets": ["9"]}, "author_link": ["97631", "97638", "97634", "97635", "97633", "97636", "97637", "97632"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2003-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "9", "bibliographicPageEnd": "1234", "bibliographicPageStart": "1229", "bibliographicVolumeNumber": "26", "bibliographic_titles": [{"bibliographic_title": "Biological \u0026 Pharmaceutical Bulletin"}]}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The objective of this study was to investigate the applicability of new oxygen meters with multi-channels and disposable oxygen electrode sensors (DOX-96) on the antimicrobial susceptibility testing of clinical bacterial isolates. The oxygen amount in the wells of 96-well plates was converted into current through electrodes. Bacterial inoculation decreased the oxygen amount in the wells because viable bacteria consume the oxygen. On the other hand, a failure of bacteria to consume oxygen was observed in the presence of potent antimicrobial agents, representing a serious arrest of bacterial metabolism usually leading to stasis or death. Based on these results, the minimum inhibitory concentration was determined by DOX-96 (MICdox). The MICdox showed good agreement with MIC measured by the standard broth microdilution method (98.2%). DOX-96 was also useful for turbid samples such as Mueller-Hinton broth containing 0.1% lipid emulsion. The MICdox in turbid samples showed good agreement with those in clear samples (100.0%). These results indicate that the newly developed DOX-96 is very useful in antimicrobial susceptibility testing even in turbid clinical samples such as colloidal products and turbid biological", "subitem_description_type": "Abstract"}]}, "item_2_description_63": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "Biological \u0026 Pharmaceutical Bulletin v.26(9) p.1229-1234, 2003", "subitem_description_type": "Other"}]}, "item_2_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Pharmaceutical Society of Japan"}]}, "item_2_relation_11": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "12951463", "subitem_relation_type_select": "PMID"}}]}, "item_2_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1248/bpb.26.1229", "subitem_relation_type_select": "DOI"}}]}, "item_2_relation_42": {"attribute_name": "関係URI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "http://dx.doi.org/10.1248/bpb.26.1229"}]}]}, "item_2_source_id_10": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA10885497", "subitem_source_identifier_type": "NCID"}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "09186158", "subitem_source_identifier_type": "ISSN"}]}, "item_2_source_id_8": {"attribute_name": "EISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1347-5215", "subitem_source_identifier_type": "ISSN"}]}, "item_2_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kitahara, Takashi"}], "nameIdentifiers": [{"nameIdentifier": "97631", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Koyama, Nao"}], "nameIdentifiers": [{"nameIdentifier": "97632", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsuda, Junichi"}], "nameIdentifiers": [{"nameIdentifier": "97633", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hirakata, Yoichi"}], "nameIdentifiers": [{"nameIdentifier": "97634", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kamihira, Shimeru"}], "nameIdentifiers": [{"nameIdentifier": "97635", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kohno, Shigeru"}], "nameIdentifiers": [{"nameIdentifier": "97636", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakashima, Mikiro"}], "nameIdentifiers": [{"nameIdentifier": "97637", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sasaki, Hitoshi"}], "nameIdentifiers": [{"nameIdentifier": "97638", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-12-24"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "BPBul26_1229.pdf", "filesize": [{"value": "109.8 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 109800.0, "url": {"label": "BPBul26_1229.pdf", "url": "https://nagasaki-u.repo.nii.ac.jp/record/23141/files/BPBul26_1229.pdf"}, "version_id": "ea562ac1-880e-48d0-8b76-c8642ba039b2"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "oxygen electrode", "subitem_subject_scheme": "Other"}, {"subitem_subject": "antimicrobial susceptibility testing", "subitem_subject_scheme": "Other"}, {"subitem_subject": "oxygen meter", "subitem_subject_scheme": "Other"}, {"subitem_subject": "minimum inhibitory concentration", "subitem_subject_scheme": "Other"}, {"subitem_subject": "lipid emulsion", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Evaluation of Newly Developed Oxygen Meters with Multi-Channels and Disposable Oxygen Electrode Sensors for Antimicrobial Susceptibility Testing", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Evaluation of Newly Developed Oxygen Meters with Multi-Channels and Disposable Oxygen Electrode Sensors for Antimicrobial Susceptibility Testing"}]}, "item_type_id": "2", "owner": "2", "path": ["9"], "permalink_uri": "http://hdl.handle.net/10069/8342", "pubdate": {"attribute_name": "公開日", "attribute_value": "2007-10-12"}, "publish_date": "2007-10-12", "publish_status": "0", "recid": "23141", "relation": {}, "relation_version_is_last": true, "title": ["Evaluation of Newly Developed Oxygen Meters with Multi-Channels and Disposable Oxygen Electrode Sensors for Antimicrobial Susceptibility Testing"], "weko_shared_id": -1}
Evaluation of Newly Developed Oxygen Meters with Multi-Channels and Disposable Oxygen Electrode Sensors for Antimicrobial Susceptibility Testing
http://hdl.handle.net/10069/8342
http://hdl.handle.net/10069/834243960902-f4ac-4f2f-9a8c-190cd527c984
名前 / ファイル | ライセンス | アクション |
---|---|---|
BPBul26_1229.pdf (109.8 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-10-12 | |||||
タイトル | ||||||
タイトル | Evaluation of Newly Developed Oxygen Meters with Multi-Channels and Disposable Oxygen Electrode Sensors for Antimicrobial Susceptibility Testing | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | oxygen electrode | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | antimicrobial susceptibility testing | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | oxygen meter | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | minimum inhibitory concentration | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | lipid emulsion | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Kitahara, Takashi
× Kitahara, Takashi× Koyama, Nao× Matsuda, Junichi× Hirakata, Yoichi× Kamihira, Shimeru× Kohno, Shigeru× Nakashima, Mikiro× Sasaki, Hitoshi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The objective of this study was to investigate the applicability of new oxygen meters with multi-channels and disposable oxygen electrode sensors (DOX-96) on the antimicrobial susceptibility testing of clinical bacterial isolates. The oxygen amount in the wells of 96-well plates was converted into current through electrodes. Bacterial inoculation decreased the oxygen amount in the wells because viable bacteria consume the oxygen. On the other hand, a failure of bacteria to consume oxygen was observed in the presence of potent antimicrobial agents, representing a serious arrest of bacterial metabolism usually leading to stasis or death. Based on these results, the minimum inhibitory concentration was determined by DOX-96 (MICdox). The MICdox showed good agreement with MIC measured by the standard broth microdilution method (98.2%). DOX-96 was also useful for turbid samples such as Mueller-Hinton broth containing 0.1% lipid emulsion. The MICdox in turbid samples showed good agreement with those in clear samples (100.0%). These results indicate that the newly developed DOX-96 is very useful in antimicrobial susceptibility testing even in turbid clinical samples such as colloidal products and turbid biological | |||||
書誌情報 |
Biological & Pharmaceutical Bulletin 巻 26, 号 9, p. 1229-1234, 発行日 2003-09 |
|||||
出版者 | ||||||
出版者 | Pharmaceutical Society of Japan | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 09186158 | |||||
EISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1347-5215 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA10885497 | |||||
PubMed番号 | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | PMID | |||||
関連識別子 | 12951463 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1248/bpb.26.1229 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
関係URI | ||||||
関連名称 | http://dx.doi.org/10.1248/bpb.26.1229 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Biological & Pharmaceutical Bulletin v.26(9) p.1229-1234, 2003 |