{"_buckets": {"deposit": "73c25358-d2e4-4b49-ab50-59a4e56158fc"}, "_deposit": {"created_by": 2, "id": "2382", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "2382"}, "status": "published"}, "_oai": {"id": "oai:nagasaki-u.repo.nii.ac.jp:00002382", "sets": ["9"]}, "author_link": ["11089", "11090", "11088", "11087"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2017-05", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "19", "bibliographicPageStart": "e6906", "bibliographicVolumeNumber": "96", "bibliographic_titles": [{"bibliographic_title": "Medicine"}]}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Purpose: To report a case of non-Descemet Stripping Automated Endothelial Keratoplasty (nDSAEK) using heads-up surgery. Case/Intervention: The case was a 72-years-old man who had history of left eye blunt trauma since childhood. One year ago, the patient was diagnosed to have left posttraumatic bullous keratopathy. The patient underwent lt nDSAEK by using the heads-up three-dimensional (3D) system last July. The surgery was performed with a Rescan 700 surgical microscope (Carl Zeiss), which is integrated with intraoperative optical coherence tomography (iOCT) system. During surgery, the surgeon and audience wore 3D passive polarized glasses. A 42 inch high-definition (HD) display and 2 HD cameras (Sony) were used. With this 3D system, the nDSAEK procedure before the graft insertion into the anterior chamber was easy especially with available high magnification. Also, using iOCT of the system enables the surgeon to detect any residual fluid at the donor graft-recipient interface and locate its place to be drained. The only disadvantage of the system was the difficulty in the detection of nDSAEK graft depth in the anterior chamber, which required frequent focus change during the surgery. Although the surgeon frequently adjusted the focus for clear stereoscopic view of the graft, he did not feel any eye strain or discomfort. All other steps of the procedure were performed without any problem and postoperative course of the patient was good. Conclusion: Using heads-up surgery for performing anterior segment surgeries is encouraging and promising.", "subitem_description_type": "Abstract"}]}, "item_2_description_63": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "Medicine, 96(19), e6906; 2017", "subitem_description_type": "Other"}]}, "item_2_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Wolters Kluwer Health, Inc."}]}, "item_2_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1097/MD.0000000000006906", "subitem_relation_type_select": "DOI"}}]}, "item_2_rights_13": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "c 2017 the Author(s). Published by Wolters Kluwer Health, Inc."}, {"subitem_rights": "This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0"}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "00257974", "subitem_source_identifier_type": "ISSN"}]}, "item_2_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mohamed, Yasser Helmy"}], "nameIdentifiers": [{"nameIdentifier": "11087", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uematsu, Masafumi"}], "nameIdentifiers": [{"nameIdentifier": "11088", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Inoue, Daisuke"}], "nameIdentifiers": [{"nameIdentifier": "11089", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kitaoka, Takashi"}], "nameIdentifiers": [{"nameIdentifier": "11090", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-12-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Medicine96_6906.pdf", "filesize": [{"value": "549.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 549600.0, "url": {"label": "Medicine96_6906.pdf", "url": "https://nagasaki-u.repo.nii.ac.jp/record/2382/files/Medicine96_6906.pdf"}, "version_id": "87729b47-b61d-4bb3-821f-bf913c9ef38d"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "bullous keratopathy", "subitem_subject_scheme": "Other"}, {"subitem_subject": "heads-up surgery", "subitem_subject_scheme": "Other"}, {"subitem_subject": "non-Descemet stripping automated endothelial keratoplasty (nDSAEK)", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "First experience of nDASEK with heads-up surgery: A case report", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "First experience of nDASEK with heads-up surgery: A case report"}]}, "item_type_id": "2", "owner": "2", "path": ["9"], "permalink_uri": "http://hdl.handle.net/10069/37586", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-06-28"}, "publish_date": "2017-06-28", "publish_status": "0", "recid": "2382", "relation": {}, "relation_version_is_last": true, "title": ["First experience of nDASEK with heads-up surgery: A case report"], "weko_shared_id": -1}
First experience of nDASEK with heads-up surgery: A case report
http://hdl.handle.net/10069/37586
http://hdl.handle.net/10069/3758676d8b5dc-6728-4da3-b463-bad3f187feae
名前 / ファイル | ライセンス | アクション |
---|---|---|
Medicine96_6906.pdf (549.6 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-06-28 | |||||
タイトル | ||||||
タイトル | First experience of nDASEK with heads-up surgery: A case report | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | bullous keratopathy | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | heads-up surgery | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | non-Descemet stripping automated endothelial keratoplasty (nDSAEK) | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Mohamed, Yasser Helmy
× Mohamed, Yasser Helmy× Uematsu, Masafumi× Inoue, Daisuke× Kitaoka, Takashi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: To report a case of non-Descemet Stripping Automated Endothelial Keratoplasty (nDSAEK) using heads-up surgery. Case/Intervention: The case was a 72-years-old man who had history of left eye blunt trauma since childhood. One year ago, the patient was diagnosed to have left posttraumatic bullous keratopathy. The patient underwent lt nDSAEK by using the heads-up three-dimensional (3D) system last July. The surgery was performed with a Rescan 700 surgical microscope (Carl Zeiss), which is integrated with intraoperative optical coherence tomography (iOCT) system. During surgery, the surgeon and audience wore 3D passive polarized glasses. A 42 inch high-definition (HD) display and 2 HD cameras (Sony) were used. With this 3D system, the nDSAEK procedure before the graft insertion into the anterior chamber was easy especially with available high magnification. Also, using iOCT of the system enables the surgeon to detect any residual fluid at the donor graft-recipient interface and locate its place to be drained. The only disadvantage of the system was the difficulty in the detection of nDSAEK graft depth in the anterior chamber, which required frequent focus change during the surgery. Although the surgeon frequently adjusted the focus for clear stereoscopic view of the graft, he did not feel any eye strain or discomfort. All other steps of the procedure were performed without any problem and postoperative course of the patient was good. Conclusion: Using heads-up surgery for performing anterior segment surgeries is encouraging and promising. | |||||
書誌情報 |
Medicine 巻 96, 号 19, p. e6906, 発行日 2017-05 |
|||||
出版者 | ||||||
出版者 | Wolters Kluwer Health, Inc. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 00257974 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1097/MD.0000000000006906 | |||||
権利 | ||||||
権利情報 | c 2017 the Author(s). Published by Wolters Kluwer Health, Inc. | |||||
権利 | ||||||
権利情報 | This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Medicine, 96(19), e6906; 2017 |