WEKO3
アイテム
{"_buckets": {"deposit": "eaa6a9c9-26f7-443c-8a33-d1b5180adb70"}, "_deposit": {"created_by": 2, "id": "24401", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "24401"}, "status": "published"}, "_oai": {"id": "oai:nagasaki-u.repo.nii.ac.jp:00024401", "sets": ["1740"]}, "author_link": ["102396", "102395", "102400", "102401", "102399", "102402", "102398", "102397"], "item_3_alternative_title_19": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Study on the Suppression of Dioxins Formaition in the Combustion Gas of Municipal Waste Incinerator"}]}, "item_3_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2005-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "65", "bibliographicPageEnd": "12", "bibliographicPageStart": "5", "bibliographicVolumeNumber": "36", "bibliographic_titles": [{"bibliographic_title": "長崎大学工学部研究報告"}, {"bibliographic_title": "Reports of the Faculty of Engineering, Nagasaki University", "bibliographic_titleLang": "en"}]}]}, "item_3_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Dioxins in the combustion gas of Municipal Solid Waste Incinerator(MSWI) are resynthesized during passing through the lower temperature region between the outlet exhaust boiler and the outlet gas duct. As a countermeasure , a spray water injection method is effective which prevents dioxins from resynthesizing by rapidly cooling down the gas temperature less than the temperature required for resynthesizing of dioxins. Using the evaporation rate of a water droplet calculated by Mizutani’s evaporation theory and the dioxins formation rate estimated by the theory of Altwicker and Stanmore, we have developed Excel program for predicting the combustion gas cooling rate and dioxins formation rate. A dioxins suppression factor was found to be dependent on the spray water droplet diameter. Therefore, some simulations have been done using real incinerator data. As a result, gas cooling rate, dioxins formation rate and dioxins product quantity can be estimated. If incinerator waste material element analysis will be available, the Excel program will be able to estimate the incinerator dioxins product quantity easily.", "subitem_description_type": "Abstract"}]}, "item_3_description_64": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "長崎大学工学部研究報告 Vol.35(65), pp.5-12; 2005", "subitem_description_type": "Other"}]}, "item_3_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "102399", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Kubota, Eiji"}]}, {"nameIdentifiers": [{"nameIdentifier": "102400", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Shigechi, Toru"}]}, {"nameIdentifiers": [{"nameIdentifier": "102401", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Momoki, Satoru"}]}, {"nameIdentifiers": [{"nameIdentifier": "102402", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Yamada, Takashi"}]}]}, "item_3_source_id_10": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA12080680", "subitem_source_identifier_type": "NCID"}]}, "item_3_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "18805574", "subitem_source_identifier_type": "ISSN"}]}, "item_3_text_62": {"attribute_name": "sortkey", "attribute_value_mlt": [{"subitem_text_value": "P00005-P00012"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "久保田, 英士"}], "nameIdentifiers": [{"nameIdentifier": "102395", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "茂地, 徹"}], "nameIdentifiers": [{"nameIdentifier": "102396", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "桃木, 悟"}], "nameIdentifiers": [{"nameIdentifier": "102397", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田, たかし"}], "nameIdentifiers": [{"nameIdentifier": "102398", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-12-24"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "35_65_02.pdf", "filesize": [{"value": "347.4 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 347400.0, "url": {"label": "35_65_02.pdf", "url": "https://nagasaki-u.repo.nii.ac.jp/record/24401/files/35_65_02.pdf"}, "version_id": "8f655017-23f8-4852-9121-d23fade336df"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "都市ゴミ焼却炉ガス中のダイオキシン類の生成抑制に関する研究", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "都市ゴミ焼却炉ガス中のダイオキシン類の生成抑制に関する研究"}]}, "item_type_id": "3", "owner": "2", "path": ["1740"], "permalink_uri": "http://hdl.handle.net/10069/3759", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-04-24"}, "publish_date": "2006-04-24", "publish_status": "0", "recid": "24401", "relation": {}, "relation_version_is_last": true, "title": ["都市ゴミ焼却炉ガス中のダイオキシン類の生成抑制に関する研究"], "weko_shared_id": -1}
都市ゴミ焼却炉ガス中のダイオキシン類の生成抑制に関する研究
http://hdl.handle.net/10069/3759
http://hdl.handle.net/10069/37599e6ba5e2-46e6-4175-a2d8-0eec8e6a7830
名前 / ファイル | ライセンス | アクション |
---|---|---|
35_65_02.pdf (347.4 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-04-24 | |||||
タイトル | ||||||
タイトル | 都市ゴミ焼却炉ガス中のダイオキシン類の生成抑制に関する研究 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
久保田, 英士
× 久保田, 英士× 茂地, 徹× 桃木, 悟× 山田, たかし |
|||||
著者別名 | ||||||
姓名 | Kubota, Eiji | |||||
著者別名 | ||||||
姓名 | Shigechi, Toru | |||||
著者別名 | ||||||
姓名 | Momoki, Satoru | |||||
著者別名 | ||||||
姓名 | Yamada, Takashi | |||||
その他のタイトル | ||||||
その他のタイトル | Study on the Suppression of Dioxins Formaition in the Combustion Gas of Municipal Waste Incinerator | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Dioxins in the combustion gas of Municipal Solid Waste Incinerator(MSWI) are resynthesized during passing through the lower temperature region between the outlet exhaust boiler and the outlet gas duct. As a countermeasure , a spray water injection method is effective which prevents dioxins from resynthesizing by rapidly cooling down the gas temperature less than the temperature required for resynthesizing of dioxins. Using the evaporation rate of a water droplet calculated by Mizutani’s evaporation theory and the dioxins formation rate estimated by the theory of Altwicker and Stanmore, we have developed Excel program for predicting the combustion gas cooling rate and dioxins formation rate. A dioxins suppression factor was found to be dependent on the spray water droplet diameter. Therefore, some simulations have been done using real incinerator data. As a result, gas cooling rate, dioxins formation rate and dioxins product quantity can be estimated. If incinerator waste material element analysis will be available, the Excel program will be able to estimate the incinerator dioxins product quantity easily. | |||||
書誌情報 |
長崎大学工学部研究報告 en : Reports of the Faculty of Engineering, Nagasaki University 巻 36, 号 65, p. 5-12, 発行日 2005-07 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 18805574 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12080680 | |||||
sortkey | ||||||
P00005-P00012 | ||||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 長崎大学工学部研究報告 Vol.35(65), pp.5-12; 2005 |