WEKO3
アイテム
{"_buckets": {"deposit": "42aa09d1-8fc9-499e-bc2b-885c36e3e2a2"}, "_deposit": {"created_by": 2, "id": "5033", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "5033"}, "status": "published"}, "_oai": {"id": "oai:nagasaki-u.repo.nii.ac.jp:00005033", "sets": ["28"]}, "author_link": ["20719", "20721", "20718", "20720", "20722", "20723"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2013-11-30", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "6", "bibliographicPageEnd": "945", "bibliographicPageStart": "939", "bibliographicVolumeNumber": "32", "bibliographic_titles": [{"bibliographic_title": "Dental Materials Journal"}]}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The purpose of this study was to evaluate and compare the bond strengths between resin composite veneer and laser-sintered cobalt-chromium (Co-Cr) alloy with and without retention devices (Laser-R and Laser-N respectively). Cast Co-Cr alloy with and without retention devices (Cast-R and Cast-N respectively) were also prepared for fabrication technique comparison. Disk-shaped Co-Cr alloy specimens were air-abraded with alumina and veneered with a veneering system, Estenia C\u0026B (ES) or Ceramage (CE). After 20,000 thermocycles, tensile testing was performed. Data were analyzed by ANOVA and multiple comparison test. When no retention devices were present, no significant differences were observed between Laser-N/ES and Cast-N/ES, or between Laser- N/CE and Cast-N/CE, but ES exhibited significantly higher bond strength than CE. With retention devices, Laser-R/ES, Cast- R/ES and Laser-R/CE showed no significant differences, and their retention strengths were significantly higher than that of Cast- R/CE. Compared to cast Co-Cr alloy, laser-sintered Co-Cr alloy with retention devices provided better retention durability for resin composite-veneered prostheses.", "subitem_description_type": "Abstract"}]}, "item_2_description_63": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "Dental Materials Journal, 32(6), pp.939-945; 2013", "subitem_description_type": "Other"}]}, "item_2_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本歯科理工学会"}]}, "item_2_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.4012/dmj.2013-082", "subitem_relation_type_select": "DOI"}}]}, "item_2_rights_13": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "c 2013 The Japanese Society for Dental Materials and Devices"}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "02874547", "subitem_source_identifier_type": "ISSN"}]}, "item_2_source_id_8": {"attribute_name": "EISSN", "attribute_value_mlt": [{"subitem_source_identifier": "18811361", "subitem_source_identifier_type": "ISSN"}]}, "item_2_text_62": {"attribute_name": "出版者別言語", "attribute_value_mlt": [{"subitem_text_value": "Japanese Society for Dental Materials and Devices"}]}, "item_2_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Muratomi, Ryuta"}], "nameIdentifiers": [{"nameIdentifier": "20718", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kamada, Kohji"}], "nameIdentifiers": [{"nameIdentifier": "20719", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Taira, Yohsuke"}], "nameIdentifiers": [{"nameIdentifier": "20720", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Higuchi, Shizuo"}], "nameIdentifiers": [{"nameIdentifier": "20721", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Watanabe, Ikuya"}], "nameIdentifiers": [{"nameIdentifier": "20722", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sawase, Takashi"}], "nameIdentifiers": [{"nameIdentifier": "20723", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-12-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "DMJ32_939.pdf", "filesize": [{"value": "1.2 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1200000.0, "url": {"label": "DMJ32_939.pdf", "url": "https://nagasaki-u.repo.nii.ac.jp/record/5033/files/DMJ32_939.pdf"}, "version_id": "a5eca26d-c757-4e80-b8d4-024e2f75ba9b"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Co-Cr alloy", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Laser sintering", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Resin", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Retention strength", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Comparative study between laser sintering and casting for retention of resin composite veneers to cobalt-chromium alloy", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Comparative study between laser sintering and casting for retention of resin composite veneers to cobalt-chromium alloy"}]}, "item_type_id": "2", "owner": "2", "path": ["28"], "permalink_uri": "http://hdl.handle.net/10069/34066", "pubdate": {"attribute_name": "公開日", "attribute_value": "2014-01-23"}, "publish_date": "2014-01-23", "publish_status": "0", "recid": "5033", "relation": {}, "relation_version_is_last": true, "title": ["Comparative study between laser sintering and casting for retention of resin composite veneers to cobalt-chromium alloy"], "weko_shared_id": -1}
Comparative study between laser sintering and casting for retention of resin composite veneers to cobalt-chromium alloy
http://hdl.handle.net/10069/34066
http://hdl.handle.net/10069/34066e0e13632-8c6d-4b04-8db1-a9548d8a30cc
名前 / ファイル | ライセンス | アクション |
---|---|---|
DMJ32_939.pdf (1.2 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-01-23 | |||||
タイトル | ||||||
タイトル | Comparative study between laser sintering and casting for retention of resin composite veneers to cobalt-chromium alloy | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Co-Cr alloy | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Laser sintering | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Resin | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Retention strength | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Muratomi, Ryuta
× Muratomi, Ryuta× Kamada, Kohji× Taira, Yohsuke× Higuchi, Shizuo× Watanabe, Ikuya× Sawase, Takashi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The purpose of this study was to evaluate and compare the bond strengths between resin composite veneer and laser-sintered cobalt-chromium (Co-Cr) alloy with and without retention devices (Laser-R and Laser-N respectively). Cast Co-Cr alloy with and without retention devices (Cast-R and Cast-N respectively) were also prepared for fabrication technique comparison. Disk-shaped Co-Cr alloy specimens were air-abraded with alumina and veneered with a veneering system, Estenia C&B (ES) or Ceramage (CE). After 20,000 thermocycles, tensile testing was performed. Data were analyzed by ANOVA and multiple comparison test. When no retention devices were present, no significant differences were observed between Laser-N/ES and Cast-N/ES, or between Laser- N/CE and Cast-N/CE, but ES exhibited significantly higher bond strength than CE. With retention devices, Laser-R/ES, Cast- R/ES and Laser-R/CE showed no significant differences, and their retention strengths were significantly higher than that of Cast- R/CE. Compared to cast Co-Cr alloy, laser-sintered Co-Cr alloy with retention devices provided better retention durability for resin composite-veneered prostheses. | |||||
書誌情報 |
Dental Materials Journal 巻 32, 号 6, p. 939-945, 発行日 2013-11-30 |
|||||
出版者 | ||||||
出版者 | 日本歯科理工学会 | |||||
出版者別言語 | ||||||
Japanese Society for Dental Materials and Devices | ||||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 02874547 | |||||
EISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 18811361 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.4012/dmj.2013-082 | |||||
権利 | ||||||
権利情報 | c 2013 The Japanese Society for Dental Materials and Devices | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Dental Materials Journal, 32(6), pp.939-945; 2013 |