WEKO3
アイテム
{"_buckets": {"deposit": "bfbfc50b-5459-4a3b-8912-e67fa2ff4e1f"}, "_deposit": {"created_by": 2, "id": "70", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "70"}, "status": "published"}, "_oai": {"id": "oai:nagasaki-u.repo.nii.ac.jp:00000070", "sets": ["11"]}, "author_link": ["335", "336", "337", "338", "334", "339", "333", "340"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2020-09-04", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "36", "bibliographicPageStart": "e21890", "bibliographicVolumeNumber": "99", "bibliographic_titles": [{"bibliographic_title": "Medicine"}]}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The outcomes of carbon dioxide digital subtraction angiography (CO2-DSA) for performing percutaneous transluminal balloon angioplasty (balloon PTA)in hemodialysis patients has not been fully clarified. The purpose was to compare the outcomes of balloon PTA of hemodialysis shunts in terms of vessel patency between patients treated using CO2-DSA and conventional digital subtraction angiography using iodine contrast medium (C-DSA).We retrospectively evaluated 76 patients (38 males and 38 females,mean age: 65.0?±?14.0 years). They were under hemodialysis and treated with balloon PTA using CO2-DSA or C-DSA at our institution between 2009 and 2016. Mean duration of the follow-up period was 25.59?±?21.45 months.We compared the patency rates obtained after CO2-DSA-based balloon PTA with those after C-DSA-based balloon PTA. Secondary patency, which was defined as the duration of patency after all further endovascular interventions until surgical repair, was considered as the endpoint in this study.Overall, 19 and 57 patients underwent CO2-DSA- and C-DSA-based balloon PTA, respectively. CO2-DSA- and C-DSA-based balloon PTA produced clinical success rates of 100% and 96.5%, respectively. Blood vessel injury occurred in one patient who underwent C-DSA-based balloon PTA. No major complications occurred in CO2 group. At 24 months, the post-PTA secondary patency rates of CO2-DSA- and C-DSA-based balloon PTA were 94.1% and 93.9%,respectively (P?=?.9594).CO2-DSA is safe for hemodialysis patients. Compared with C-DSA, CO2-DSA-based balloon \nPTA produces have a similar secondary patency rate.", "subitem_description_type": "Abstract"}]}, "item_2_description_63": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "Medicine, 99(36), e21890; 2020", "subitem_description_type": "Other"}]}, "item_2_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Wolters Kluwer Health, Inc."}]}, "item_2_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1097/MD.0000000000021890", "subitem_relation_type_select": "DOI"}}]}, "item_2_rights_13": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "c 2020 the Author(s). Published by Wolters Kluwer Health, Inc. This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it ispermissible to download, share, remix,transform, and buildup the work providedit is properly cited. The work cannot be used commercially without permission from the journal."}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "00257974", "subitem_source_identifier_type": "ISSN"}]}, "item_2_source_id_8": {"attribute_name": "EISSN", "attribute_value_mlt": [{"subitem_source_identifier": "15365964", "subitem_source_identifier_type": "ISSN"}]}, "item_2_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Tasaki, Yutaro"}], "nameIdentifiers": [{"nameIdentifier": "333", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sueyoshi, Eijun"}], "nameIdentifiers": [{"nameIdentifier": "334", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takamatsu, Hiroko"}], "nameIdentifiers": [{"nameIdentifier": "335", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsushima, Yoshifumi"}], "nameIdentifiers": [{"nameIdentifier": "336", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miyamura, Shuto"}], "nameIdentifiers": [{"nameIdentifier": "337", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakamoto, Ichiro"}], "nameIdentifiers": [{"nameIdentifier": "338", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mochizuki, Yasushi"}], "nameIdentifiers": [{"nameIdentifier": "339", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uetani, Masataka"}], "nameIdentifiers": [{"nameIdentifier": "340", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-12-16"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Medicine99_21890.pdf", "filesize": [{"value": "352.4 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 352400.0, "url": {"label": "Medicine99_21890.pdf", "url": "https://nagasaki-u.repo.nii.ac.jp/record/70/files/Medicine99_21890.pdf"}, "version_id": "ea30c55f-6a45-49fb-95c1-ff7454748405"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "CO2", "subitem_subject_scheme": "Other"}, {"subitem_subject": "dialysis", "subitem_subject_scheme": "Other"}, {"subitem_subject": "interventional radiology", "subitem_subject_scheme": "Other"}, {"subitem_subject": "PTA", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "The outcomes of carbon dioxide digital subtraction angiography for percutaneous transluminal balloon angioplasty of access circuits and venous routes in hemodialysis patients", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "The outcomes of carbon dioxide digital subtraction angiography for percutaneous transluminal balloon angioplasty of access circuits and venous routes in hemodialysis patients"}]}, "item_type_id": "2", "owner": "2", "path": ["11"], "permalink_uri": "http://hdl.handle.net/10069/40297", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-09-25"}, "publish_date": "2020-09-25", "publish_status": "0", "recid": "70", "relation": {}, "relation_version_is_last": true, "title": ["The outcomes of carbon dioxide digital subtraction angiography for percutaneous transluminal balloon angioplasty of access circuits and venous routes in hemodialysis patients"], "weko_shared_id": -1}
The outcomes of carbon dioxide digital subtraction angiography for percutaneous transluminal balloon angioplasty of access circuits and venous routes in hemodialysis patients
http://hdl.handle.net/10069/40297
http://hdl.handle.net/10069/4029723edd833-3911-48dd-8ea8-6d21ae7ef6c1
名前 / ファイル | ライセンス | アクション |
---|---|---|
Medicine99_21890.pdf (352.4 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-09-25 | |||||
タイトル | ||||||
タイトル | The outcomes of carbon dioxide digital subtraction angiography for percutaneous transluminal balloon angioplasty of access circuits and venous routes in hemodialysis patients | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | CO2 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | dialysis | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | interventional radiology | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | PTA | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Tasaki, Yutaro
× Tasaki, Yutaro× Sueyoshi, Eijun× Takamatsu, Hiroko× Matsushima, Yoshifumi× Miyamura, Shuto× Sakamoto, Ichiro× Mochizuki, Yasushi× Uetani, Masataka |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The outcomes of carbon dioxide digital subtraction angiography (CO2-DSA) for performing percutaneous transluminal balloon angioplasty (balloon PTA)in hemodialysis patients has not been fully clarified. The purpose was to compare the outcomes of balloon PTA of hemodialysis shunts in terms of vessel patency between patients treated using CO2-DSA and conventional digital subtraction angiography using iodine contrast medium (C-DSA).We retrospectively evaluated 76 patients (38 males and 38 females,mean age: 65.0?±?14.0 years). They were under hemodialysis and treated with balloon PTA using CO2-DSA or C-DSA at our institution between 2009 and 2016. Mean duration of the follow-up period was 25.59?±?21.45 months.We compared the patency rates obtained after CO2-DSA-based balloon PTA with those after C-DSA-based balloon PTA. Secondary patency, which was defined as the duration of patency after all further endovascular interventions until surgical repair, was considered as the endpoint in this study.Overall, 19 and 57 patients underwent CO2-DSA- and C-DSA-based balloon PTA, respectively. CO2-DSA- and C-DSA-based balloon PTA produced clinical success rates of 100% and 96.5%, respectively. Blood vessel injury occurred in one patient who underwent C-DSA-based balloon PTA. No major complications occurred in CO2 group. At 24 months, the post-PTA secondary patency rates of CO2-DSA- and C-DSA-based balloon PTA were 94.1% and 93.9%,respectively (P?=?.9594).CO2-DSA is safe for hemodialysis patients. Compared with C-DSA, CO2-DSA-based balloon PTA produces have a similar secondary patency rate. |
|||||
書誌情報 |
Medicine 巻 99, 号 36, p. e21890, 発行日 2020-09-04 |
|||||
出版者 | ||||||
出版者 | Wolters Kluwer Health, Inc. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 00257974 | |||||
EISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 15365964 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1097/MD.0000000000021890 | |||||
権利 | ||||||
権利情報 | c 2020 the Author(s). Published by Wolters Kluwer Health, Inc. This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it ispermissible to download, share, remix,transform, and buildup the work providedit is properly cited. The work cannot be used commercially without permission from the journal. | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Medicine, 99(36), e21890; 2020 |