WEKO3
アイテム
{"_buckets": {"deposit": "b6140db9-47d8-4adb-b1ea-fb46b408945f"}, "_deposit": {"created_by": 6, "id": "27600", "owners": [6], "pid": {"revision_id": 0, "type": "depid", "value": "27600"}, "status": "published"}, "_oai": {"id": "oai:nagasaki-u.repo.nii.ac.jp:00027600", "sets": ["21"]}, "author_link": ["122753"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2022-07-20", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "7", "bibliographicPageStart": "1054", "bibliographicVolumeNumber": "12", "bibliographic_titles": [{"bibliographic_title": "Buildings"}]}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In Japan, the standard of indoor climate in nursery school classrooms has not been established, and the control and maintenance of indoor climate in the classrooms are entrusted to individual childminders. Therefore, indoor climate in nursery school classrooms was measured to prepare fundamental information for proper environmental design and environmental control, considering infants’ comfort and health. The climate of 0-year-old and 1-year-old children’s rooms in 15 nursery schools located in mild climatic areas in Japan were measured in the summer and winter over four years. Consequently, a lower average temperature was found during winter at lower heights at which infants spend time and indoor air quality was found to be poor in both summer and winter due to a lower ventilation rate in some classrooms with a smaller area per infant compared to the minimum standards for child welfare institutions. One classroom with an average CO2 concentration of over 1500 ppm was found in both summer and winter due to less ventilation. Illumination less than 300 lx in one-third of the studied classrooms and high equivalent noise level in most classrooms were measured. The need for indoor environmental standards was indicated in terms of infants’ comfort and health.", "subitem_description_type": "Abstract"}]}, "item_2_description_63": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "Buildings, 12(7), art. no. 1054; 2022", "subitem_description_type": "Other"}]}, "item_2_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "MDPI"}]}, "item_2_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.3390/buildings12071054", "subitem_relation_type_select": "DOI"}}]}, "item_2_rights_13": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "© 2022 by the author. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/)."}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "2075-5309", "subitem_source_identifier_type": "ISSN"}]}, "item_2_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Genjo, Kahori"}], "nameIdentifiers": [{"nameIdentifier": "122753", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2022-09-26"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "B12_1054.pdf", "filesize": [{"value": "6.6 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 6600000.0, "url": {"label": "B12_1054.pdf", "url": "https://nagasaki-u.repo.nii.ac.jp/record/27600/files/B12_1054.pdf"}, "version_id": "41157567-9429-4bfd-951a-479e10cae962"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "nursery", "subitem_subject_scheme": "Other"}, {"subitem_subject": "classrooms", "subitem_subject_scheme": "Other"}, {"subitem_subject": "vertical temperature difference", "subitem_subject_scheme": "Other"}, {"subitem_subject": "humidity", "subitem_subject_scheme": "Other"}, {"subitem_subject": "CO2", "subitem_subject_scheme": "Other"}, {"subitem_subject": "air stuffiness index", "subitem_subject_scheme": "Other"}, {"subitem_subject": "particle matter", "subitem_subject_scheme": "Other"}, {"subitem_subject": "illumination", "subitem_subject_scheme": "Other"}, {"subitem_subject": "noise level", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Assessment of Indoor Climate for Infants in Nursery School Classrooms in Mild Climatic Areas in Japan", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Assessment of Indoor Climate for Infants in Nursery School Classrooms in Mild Climatic Areas in Japan"}]}, "item_type_id": "2", "owner": "6", "path": ["21"], "permalink_uri": "http://hdl.handle.net/10069/00041736", "pubdate": {"attribute_name": "公開日", "attribute_value": "2022-09-26"}, "publish_date": "2022-09-26", "publish_status": "0", "recid": "27600", "relation": {}, "relation_version_is_last": true, "title": ["Assessment of Indoor Climate for Infants in Nursery School Classrooms in Mild Climatic Areas in Japan"], "weko_shared_id": -1}
Assessment of Indoor Climate for Infants in Nursery School Classrooms in Mild Climatic Areas in Japan
http://hdl.handle.net/10069/00041736
http://hdl.handle.net/10069/00041736a3546330-11d5-428d-92d3-cfd61ad31988
名前 / ファイル | ライセンス | アクション |
---|---|---|
B12_1054.pdf (6.6 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-09-26 | |||||
タイトル | ||||||
タイトル | Assessment of Indoor Climate for Infants in Nursery School Classrooms in Mild Climatic Areas in Japan | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | nursery | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | classrooms | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | vertical temperature difference | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | humidity | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | CO2 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | air stuffiness index | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | particle matter | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | illumination | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | noise level | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Genjo, Kahori
× Genjo, Kahori |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In Japan, the standard of indoor climate in nursery school classrooms has not been established, and the control and maintenance of indoor climate in the classrooms are entrusted to individual childminders. Therefore, indoor climate in nursery school classrooms was measured to prepare fundamental information for proper environmental design and environmental control, considering infants’ comfort and health. The climate of 0-year-old and 1-year-old children’s rooms in 15 nursery schools located in mild climatic areas in Japan were measured in the summer and winter over four years. Consequently, a lower average temperature was found during winter at lower heights at which infants spend time and indoor air quality was found to be poor in both summer and winter due to a lower ventilation rate in some classrooms with a smaller area per infant compared to the minimum standards for child welfare institutions. One classroom with an average CO2 concentration of over 1500 ppm was found in both summer and winter due to less ventilation. Illumination less than 300 lx in one-third of the studied classrooms and high equivalent noise level in most classrooms were measured. The need for indoor environmental standards was indicated in terms of infants’ comfort and health. | |||||
書誌情報 |
Buildings 巻 12, 号 7, p. 1054, 発行日 2022-07-20 |
|||||
出版者 | ||||||
出版者 | MDPI | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2075-5309 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.3390/buildings12071054 | |||||
権利 | ||||||
権利情報 | © 2022 by the author. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Buildings, 12(7), art. no. 1054; 2022 |