{"created":"2023-05-15T16:37:11.806374+00:00","id":10500,"links":{},"metadata":{"_buckets":{"deposit":"498fae9f-c49b-46b8-9bcb-995e175557cf"},"_deposit":{"created_by":2,"id":"10500","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"10500"},"status":"published"},"_oai":{"id":"oai:nagasaki-u.repo.nii.ac.jp:00010500","sets":["29:30"]},"author_link":["41682","41681"],"item_2_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2011-12-01","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"717","bibliographicPageStart":"712","bibliographicVolumeNumber":"10","bibliographic_titles":[{"bibliographic_title":"JOURNAL OF SPORTS SCIENCE & MEDICINE"}]}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The purpose of this study was to develop a standardized and\nexternally paced field test (15-m Incremental Shuttle Walk and Run Test [15mISWRT]), incorporating an incremental and\nprogressive structure, to assess aerobic fitness in middle-aged adults. 68 middle-aged men performed three tests in random order between one to two week intervals: 15-m ISWRT, cardiopulmonary exercise test (CPX), and 1500-m fast walk. Variables evaluated were 15-m ISWRT performance (distance completed), VO2max measured by CPX, 1500-m fast walk performance (walking time), and HR response in 15-m ISWRT and 1500-m fast walk. Validity of the 15-m ISWRT was tested by comparing the associations among the 15-m ISWRT performance, VO2max and the 1500-m fast walk performance. Changes in HR response during the 15-m ISWRT and the 1500-m fast walk were also compared. Correlations between each variable were as follows: the correlation between 15-m ISWRT performance and VO2max was very high, r = 0.86 (p < 0.01), the correlation between the 1500-m fast walk and VO2max was r = −0.51 (p < 0.01). HR response during the 15-m ISWRT gently increased initially, whereas HR response during the 1500-m fast walk rapidly increased from the start. In conclusion, our findings indicate that the 15-m ISWRT is valid and safe for evaluating VO2max in middle-aged adults.","subitem_description_type":"Abstract"}]},"item_2_description_63":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"JOURNAL OF SPORTS SCIENCE & MEDICINE, 10, pp.712-717; 2011","subitem_description_type":"Other"}]},"item_2_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Asist Group"}]},"item_2_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Reprinted from JOURNAL OF SPORTS SCIENCE AND MEDICINE, 10, Kotaro Mikawa and Hideaki Senjyu, DEVELOPMENT OF A FIELD TEST FOR EVALUATING AEROBIC FITNESS IN MIDDLE-AGED ADULTS: VALIDITY OF A 15-M INCREMENTAL SHUTTLE WALK AND RUN TEST, pp.712-717, Copyright 2011, with permission from the JOURNAL OF SPORTS SCIENCE AND MEDICINE."}]},"item_2_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13032968","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kotaro, Mikawa"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Hideaki, Senjyu"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-12-22"}],"displaytype":"detail","filename":"JSSM10_712.pdf","filesize":[{"value":"304.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"JSSM10_712.pdf","url":"https://nagasaki-u.repo.nii.ac.jp/record/10500/files/JSSM10_712.pdf"},"version_id":"8702e767-6689-4b90-889f-90a9a480d14d"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Maximal oxygen uptake","subitem_subject_scheme":"Other"},{"subitem_subject":"heart rate","subitem_subject_scheme":"Other"},{"subitem_subject":"20m shuttle run test","subitem_subject_scheme":"Other"},{"subitem_subject":"shuttle walking test","subitem_subject_scheme":"Other"},{"subitem_subject":"cardiopulmonary exercise test","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Development of a field test for evaluating aerobic fitness in middle-aged adults: Validity of a 15-m Incremental Shuttle Walk and Run Test","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Development of a field test for evaluating aerobic fitness in middle-aged adults: Validity of a 15-m Incremental Shuttle Walk and Run Test"}]},"item_type_id":"2","owner":"2","path":["30"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-08-16"},"publish_date":"2012-08-16","publish_status":"0","recid":"10500","relation_version_is_last":true,"title":["Development of a field test for evaluating aerobic fitness in middle-aged adults: Validity of a 15-m Incremental Shuttle Walk and Run Test"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-05-16T01:26:05.917216+00:00"}