{"created":"2023-05-15T16:39:39.649024+00:00","id":13637,"links":{},"metadata":{"_buckets":{"deposit":"3c9c8565-da17-4760-884d-c99ae08be34c"},"_deposit":{"created_by":2,"id":"13637","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"13637"},"status":"published"},"_oai":{"id":"oai:nagasaki-u.repo.nii.ac.jp:00013637","sets":["8:9"]},"author_link":["49218","49216","49217","49219","49220"],"item_2_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2011-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"183","bibliographicPageStart":"181","bibliographicVolumeNumber":"31","bibliographic_titles":[{"bibliographic_title":"Retina (Philadelphia, Pa.)"}]}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Background: Although widely accepted, pars plana vitrectomy is difficult to perform when patients have a large filtering bleb. We describe technical details of 25-gauge transcorneal vitrectomy and the clinical outcomes. Methods: We performed 25-gauge transcorneal vitrectomy on seven eyes of seven patients (female: male, 4:3; age, 39 to 77 years; mean, 66.1 years) between January 2005 and February 2007. Phacoemulsification via a corneal incision was followed by continuous curvilinear capsulorrhexis (CCC) of the posterior capsule. We used a notched contact lens to perform 25-gauge transcorneal vitrectomy. Results: Four patients with idiopathic ERM and three with secondary ERM were treated by 25-gauge vitrectomy. Postoperative visual acuity was good in most of them and the cell density of the corneal endothelium was maintained. Conclusion: These advantages of this procedure are that the conjunctiva and ocular surface can be completely maintained and vitreous incarceration can be avoided. Thus, 25-gauge vitrectomy might be particularly suitable for treating glaucoma with a filtering bleb. (158 words/200 words)","subitem_description_type":"Abstract"}]},"item_2_description_63":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"Retina, 31(1), pp.181-183; 2011","subitem_description_type":"Other"}]},"item_2_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Lippincott Williams & Wilkins Ltd."}]},"item_2_relation_11":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"21187735","subitem_relation_type_select":"PMID"}}]},"item_2_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1097/IAE.0b013e3181fe54e6","subitem_relation_type_select":"DOI"}}]},"item_2_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© The Ophthalmic Communications Society, Inc."},{"subitem_rights":"This is a non-final version of an article published in final form in Retina, 31(1), pp.181-183; 2011."}]},"item_2_source_id_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA10639923","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0275004X","subitem_source_identifier_type":"ISSN"}]},"item_2_source_id_8":{"attribute_name":"EISSN","attribute_value_mlt":[{"subitem_source_identifier":"15392864","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Matsumoto, Makiko"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Suzuma, Kiyoshi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Miyamura, Noritake"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tsuiki, Eiko"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kitaoka, Takashi"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-12-22"}],"displaytype":"detail","filename":"Retina31_181.pdf","filesize":[{"value":"168.2 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Retina31_181.pdf","url":"https://nagasaki-u.repo.nii.ac.jp/record/13637/files/Retina31_181.pdf"},"version_id":"90a562d5-9985-4f31-ac68-62afc4330cb7"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"25-gauge system","subitem_subject_scheme":"Other"},{"subitem_subject":"epiretinal membrane","subitem_subject_scheme":"Other"},{"subitem_subject":"filtering bleb","subitem_subject_scheme":"Other"},{"subitem_subject":"glaucoma","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Transcorneal three-port vitrectomy without conjunctival incision.","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Transcorneal three-port vitrectomy without conjunctival incision."}]},"item_type_id":"2","owner":"2","path":["9"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-02-01"},"publish_date":"2012-02-01","publish_status":"0","recid":"13637","relation_version_is_last":true,"title":["Transcorneal three-port vitrectomy without conjunctival incision."],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-05-16T00:34:41.024308+00:00"}