{"created":"2023-05-15T16:39:51.589511+00:00","id":13899,"links":{},"metadata":{"_buckets":{"deposit":"d6f5f87e-3afa-4699-9895-a307b2abfbae"},"_deposit":{"created_by":2,"id":"13899","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"13899"},"status":"published"},"_oai":{"id":"oai:nagasaki-u.repo.nii.ac.jp:00013899","sets":["14:65"]},"author_link":["49831","49833","49829","49830","49832"],"item_9_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2010-09","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"176","bibliographicPageStart":"173","bibliographic_titles":[{"bibliographic_title":"2010 International Conference on Environmental Engineering and Applications"}]}]},"item_9_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Recently, a number of studies have pointed out that Electric Conductivity (EC) would be a very effective measure for monitoring the quality of ground water possibly polluted by sewage sludge or incineration ash leachate. However, few have explicitly determined the allowable limit of the EC value. Therefore, we have obtained the allowable limit of EC by applying the \"benchmark dose (BMO)\" method.","subitem_description_type":"Abstract"}]},"item_9_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"2010 International Conference on Environmental Engineering and Applications (ICEEA) : Singapore, Singapore, 2010.09.10-2010.09.12","subitem_description_type":"Other"}]},"item_9_description_63":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"ICEEA 2010, pp.173-176","subitem_description_type":"Other"}]},"item_9_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE"}]},"item_9_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1109/ICEEA.2010.5596121","subitem_relation_type_select":"DOI"}}]},"item_9_relation_9":{"attribute_name":"ISBN","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"978-1-4244-8619-9","subitem_relation_type_select":"ISBN"}}]},"item_9_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2010 IEEE."}]},"item_9_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Ito, Hidenori"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Saunders, Todd"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Miyamoto, Junya"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Nishiyama, Masaya"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Nakamura, Tsuyoshi"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-12-22"}],"displaytype":"detail","filename":"ICEEA2010_173.pdf","filesize":[{"value":"1.6 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ICEEA2010_173.pdf","url":"https://nagasaki-u.repo.nii.ac.jp/record/13899/files/ICEEA2010_173.pdf"},"version_id":"1261b98a-2b51-4a9d-94dc-7a381ef8ffc9"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Bench mark dose","subitem_subject_scheme":"Other"},{"subitem_subject":"Component","subitem_subject_scheme":"Other"},{"subitem_subject":"Electric conductivity","subitem_subject_scheme":"Other"},{"subitem_subject":"Environmental standard","subitem_subject_scheme":"Other"},{"subitem_subject":"Incineration ash","subitem_subject_scheme":"Other"},{"subitem_subject":"Monitoring","subitem_subject_scheme":"Other"},{"subitem_subject":"Sewage sludge","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"Establishing allowable value of Electric Conductivity for monitoring groundwater based on the benchmark dose concept and its application","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Establishing allowable value of Electric Conductivity for monitoring groundwater based on the benchmark dose concept and its application"}]},"item_type_id":"9","owner":"2","path":["65"],"pubdate":{"attribute_name":"公開日","attribute_value":"2011-10-11"},"publish_date":"2011-10-11","publish_status":"0","recid":"13899","relation_version_is_last":true,"title":["Establishing allowable value of Electric Conductivity for monitoring groundwater based on the benchmark dose concept and its application"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-05-16T00:29:27.606195+00:00"}