{"created":"2023-05-15T16:39:59.851591+00:00","id":14083,"links":{},"metadata":{"_buckets":{"deposit":"2eccba8d-83d7-42a2-90ac-f0ea72268e67"},"_deposit":{"created_by":2,"id":"14083","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"14083"},"status":"published"},"_oai":{"id":"oai:nagasaki-u.repo.nii.ac.jp:00014083","sets":["14:21"]},"author_link":["50595","50592","50593","50596","50594"],"item_2_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2010-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"9","bibliographicPageEnd":"2256","bibliographicPageStart":"2250","bibliographicVolumeNumber":"E93-B","bibliographic_titles":[{"bibliographic_title":"IEICE Transactions on Communications"}]}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper proposes a new power-factor-correction (PFC) topology, and explains its operation principle, its control mechanism, related application problems followed by experimental results. In this proposed topology, critical-conduction-mode (CRM) interleaved technique is applied to a bridgeless PFC in order to achieve high efficiency by combining benefits of each topology. This application is targeted toward low to middle power applications that normally employs continuous-conductionmode boost converter.","subitem_description_type":"Abstract"}]},"item_2_description_63":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"IEICE Transactions on Communications, E93-B(9), pp.2250-2256; 2010","subitem_description_type":"Other"}]},"item_2_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"The Institute of Electronics, Information and Communication Engineers"}]},"item_2_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1587/transcom.E93.B.2250","subitem_relation_type_select":"DOI"}}]},"item_2_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 2010 The Institute of Electronics, Information and Communication Engineers."}]},"item_2_source_id_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA10826261","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"09168516","subitem_source_identifier_type":"ISSN"}]},"item_2_text_62":{"attribute_name":"出版者別言語","attribute_value_mlt":[{"subitem_text_value":"電子情報通信学会"}]},"item_2_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Firmansyah, Eka"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tomioka, Satoshi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Abe, Seiya"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Shoyama, Masahito"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Ninomiya, Tamotsu"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-12-22"}],"displaytype":"detail","filename":"IEICE93.B_2250.pdf","filesize":[{"value":"1.2 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"IEICE93.B_2250.pdf","url":"https://nagasaki-u.repo.nii.ac.jp/record/14083/files/IEICE93.B_2250.pdf"},"version_id":"80551ffd-18ad-4b34-ba25-43bc543f5782"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Critical-conduction-mode","subitem_subject_scheme":"Other"},{"subitem_subject":"Interleaved","subitem_subject_scheme":"Other"},{"subitem_subject":"PFC","subitem_subject_scheme":"Other"},{"subitem_subject":"Totem-pole","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Totem-Pole Power-Factor-Correction Converter under Critical-Conduction-Mode Interleaved Operation","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Totem-Pole Power-Factor-Correction Converter under Critical-Conduction-Mode Interleaved Operation"}]},"item_type_id":"2","owner":"2","path":["21"],"pubdate":{"attribute_name":"公開日","attribute_value":"2011-04-04"},"publish_date":"2011-04-04","publish_status":"0","recid":"14083","relation_version_is_last":true,"title":["Totem-Pole Power-Factor-Correction Converter under Critical-Conduction-Mode Interleaved Operation"],"weko_creator_id":"2","weko_shared_id":2},"updated":"2023-05-15T18:53:56.902074+00:00"}