@article{oai:nagasaki-u.repo.nii.ac.jp:00014629, author = {山田, たかし and 豊田, 香 and 茂地, 徹 and 桃木, 悟 and 山口, 朝彦}, issue = {76}, journal = {長崎大学工学部研究報告, Reports of the Faculty of Engineering, Nagasaki University}, month = {Jan}, note = {The film boiling heat transfer around a vertical silver cylinder with a convex conical bottom was investigated experimentally for quiescent water at atmosphereric pressure. The experiments have been carried out by a transient method, i.e., quenching method. The diameter of test cylinder is 32mm and the total length is 48mm with 32mm length of vertical part. The test cylinder was heated to about 600℃ in an electric furnace and then cooled in saturated and subcooled water with the immersion depth of about 100mm. The degree of liquid subcooling was varied from 0 to 30K. The film boiling heat transfer increased in terms of heat flux by 220% with 30K increase in liquid subcooling at a wall superheating of 300K. The wall superheating and heat flux at the lower limit of film boiling increased with an increase in liquid subcooling., 長崎大学工学部研究報告, 41(76), pp.13-19; 2011}, pages = {13--19}, title = {円錐状の凸底面を有する有限垂直円柱まわりの膜沸騰熱伝達の実験}, volume = {41}, year = {2011} }