{"created":"2023-05-15T16:40:28.214512+00:00","id":14744,"links":{},"metadata":{"_buckets":{"deposit":"44750399-402c-46db-9fcd-c7c1de4ef7d3"},"_deposit":{"created_by":2,"id":"14744","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"14744"},"status":"published"},"_oai":{"id":"oai:nagasaki-u.repo.nii.ac.jp:00014744","sets":["8:9"]},"author_link":["54225","54221","54220","54224","54226","54222","54223"],"item_2_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2010-11","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"11","bibliographicPageEnd":"1301","bibliographicPageStart":"1296","bibliographicVolumeNumber":"29","bibliographic_titles":[{"bibliographic_title":"Cornea"}]}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"To evaluate acute corneal epithelial toxicity induced by benzalkonium chloride (BAC) homologs with different alkyl chain lengths using an in vivo electrophysiological method.","subitem_description_type":"Abstract"}]},"item_2_description_63":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"Cornea, 29(11), pp.1296-1301; 2010","subitem_description_type":"Other"}]},"item_2_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Lippincott Williams & Wilkins Ltd."}]},"item_2_relation_11":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"20802315","subitem_relation_type_select":"PMID"}}]},"item_2_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1097/ICO.0b013e3181dc81b6","subitem_relation_type_select":"DOI"}}]},"item_2_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 2010 by Lippincott Williams & Wilkins."},{"subitem_rights":"This is a non-final version of an article published in final form in Cornea, 29(11), pp.1296-1301; 2010."}]},"item_2_source_id_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA10623220","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"02773740","subitem_source_identifier_type":"ISSN"}]},"item_2_source_id_8":{"attribute_name":"EISSN","attribute_value_mlt":[{"subitem_source_identifier":"15364798","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Uematsu, Masafumi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kumagami, Takeshi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Shimoda, Kenichiro"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kusano, Mao"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Teshima, Mugen"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Sasaki, Hitoshi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kitaoka, Takashi"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-12-22"}],"displaytype":"detail","filename":"Cornea29_1296.pdf","filesize":[{"value":"836.7 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Cornea29_1296.pdf","url":"https://nagasaki-u.repo.nii.ac.jp/record/14744/files/Cornea29_1296.pdf"},"version_id":"ae7ddbd4-52bf-461f-af7f-0092bafe7f4a"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"alkyl chain","subitem_subject_scheme":"Other"},{"subitem_subject":"barrier function","subitem_subject_scheme":"Other"},{"subitem_subject":"benzalkonium chloride","subitem_subject_scheme":"Other"},{"subitem_subject":"cornea","subitem_subject_scheme":"Other"},{"subitem_subject":"eyedrop","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Influence of alkyl chain length of benzalkonium chloride on acute corneal epithelial toxicity.","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Influence of alkyl chain length of benzalkonium chloride on acute corneal epithelial toxicity."}]},"item_type_id":"2","owner":"2","path":["9"],"pubdate":{"attribute_name":"公開日","attribute_value":"2011-12-01"},"publish_date":"2011-12-01","publish_status":"0","recid":"14744","relation_version_is_last":true,"title":["Influence of alkyl chain length of benzalkonium chloride on acute corneal epithelial toxicity."],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-05-16T00:16:25.010769+00:00"}