{"created":"2023-05-15T16:40:41.866678+00:00","id":15063,"links":{},"metadata":{"_buckets":{"deposit":"4843ae22-77e0-4359-8055-0e2b841a0ca3"},"_deposit":{"created_by":2,"id":"15063","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"15063"},"status":"published"},"_oai":{"id":"oai:nagasaki-u.repo.nii.ac.jp:00015063","sets":["14:65"]},"author_link":["55171","55174","55172","55170","55173","55175"],"item_9_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-09","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"5","bibliographicPageStart":"1","bibliographic_titles":[{"bibliographic_title":"INTELEC 2008 - 2008 IEEE 30th International Telecommunications Energy Conference"}]}]},"item_9_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper presents a new digital control circuit which is able to detect the peak switch current of the high frequency switching dc-dc converter. In this proposed digital control circuit, the peak current-injected control is realized using the combination of the simple dual pulse width modulation analog-to-digital signal converter and the programmed delay circuit. In 100kHz digitally controlled dc-dc converter, it is seen in simulation that the proposed method has no overshoot of the output voltage and the convergence time that the output voltage is settled to steady-state is only 30μs. The difference between the transient time of the proposed circuit and that of the conventional method is an order of magnitude. Furthermore, the ratio of resolution of the DPWM generator against the output voltage is 0.27% and is satisfied to apply the commercial power supply unit.","subitem_description_type":"Abstract"}]},"item_9_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"INTELEC 2008 - 2008 IEEE 30th International Telecommunications Energy Conference : San Diego, CA, 2008.09.14-2008.09.18","subitem_description_type":"Other"}]},"item_9_description_63":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"INTELEC 2008, pp.1-5; 2008","subitem_description_type":"Other"}]},"item_9_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE"}]},"item_9_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1109/INTLEC.2008.4664113","subitem_relation_type_select":"DOI"}}]},"item_9_relation_9":{"attribute_name":"ISBN","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"978-1-4244-2055-1","subitem_relation_type_select":"ISBN"}}]},"item_9_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"©2008 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE."}]},"item_9_source_id_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11087061","subitem_source_identifier_type":"NCID"}]},"item_9_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"02750473","subitem_source_identifier_type":"ISSN"}]},"item_9_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kurokawa, Fujio"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Sukita, Shohei"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Shibata, Yuichiro"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yokoyama, Tomoki"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Sasaki, Masahiro"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Mimura, Yasuhiro"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-12-23"}],"displaytype":"detail","filename":"INTELEC2008.pdf","filesize":[{"value":"812.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"INTELEC2008.pdf","url":"https://nagasaki-u.repo.nii.ac.jp/record/15063/files/INTELEC2008.pdf"},"version_id":"1185c4be-d062-4ca0-b9a4-ffb980a7823f"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"A new digital control DC-DC converter with peak current -injected control","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"A new digital control DC-DC converter with peak current -injected control"}]},"item_type_id":"9","owner":"2","path":["65"],"pubdate":{"attribute_name":"公開日","attribute_value":"2010-02-17"},"publish_date":"2010-02-17","publish_status":"0","recid":"15063","relation_version_is_last":true,"title":["A new digital control DC-DC converter with peak current -injected control"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-05-16T00:12:24.341854+00:00"}