{"created":"2023-05-15T16:40:43.754583+00:00","id":15107,"links":{},"metadata":{"_buckets":{"deposit":"aea3cee3-b8b0-4b75-be35-04260491c42e"},"_deposit":{"created_by":2,"id":"15107","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"15107"},"status":"published"},"_oai":{"id":"oai:nagasaki-u.repo.nii.ac.jp:00015107","sets":["14:21"]},"author_link":["55414","55416","55411","55412","55413","55415"],"item_2_alternative_title_19":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Remote Sensing Analysis for Salt-Damage Triggered Power Failures due to Typhoon 9119 with Reference to Vegetation Vigour"}]},"item_2_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1999-08-31","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"252","bibliographicPageStart":"241","bibliographicVolumeNumber":"18","bibliographic_titles":[{"bibliographic_title":"自然災害科学"},{"bibliographic_title":"Journal of Japan Society for Natural Disaster Science","bibliographic_titleLang":"en"}]}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The Typhoon 9119 attacked the northern part of Kyusyu District, the western part of Yamaguchi Prefecture and Hokkaido District on September 27 to 28,1991. This typhoon was so strong that considerable damages on cedars forests in Hita City, Oita Prefecture, apples orchards in Aomori Prefecture and others were yielded. One of its characteristics was a windy typhoon which triggered a lot of power failures due to salt damage in Chugoku District including Hiroshima, Yamaguchi and Okayama Prefectures. In this paper the authors analysed these power failures in Yamaguchi Prefecture by comparing two sets of the vegetation vigour data obtained from satellite remote sensing before and after the typhoon. The satellite data were MOS-1/MESSR data with the space resolution of 50 m and the vegetation vigour was calculated by RVI (Ratioed Vegetation Index). As a result the distribution map of salt damages examined by RVI almost coincided with that of salt-damage triggered power failures obtained by surveying in situ. Lastly the countermeasure against this kind of power failures was proposed with space and ground remote sensing technique.","subitem_description_type":"Abstract"}]},"item_2_description_63":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"自然災害科学, 18(2), pp. 241-252; 1999","subitem_description_type":"Other"}]},"item_2_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"55414","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Gotoh, Keinosuke"}]},{"nameIdentifiers":[{"nameIdentifier":"55415","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Goto, Kensuke"}]},{"nameIdentifiers":[{"nameIdentifier":"55416","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Ohta, Tetsuo"}]}]},"item_2_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本自然災害学会"}]},"item_2_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"日本自然災害学会"},{"subitem_rights":"本文データは学協会の許諾に基づきCiNiiから複製したものである"}]},"item_2_source_id_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN10165274","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"02866021","subitem_source_identifier_type":"ISSN"}]},"item_2_text_62":{"attribute_name":"出版者別言語","attribute_value_mlt":[{"subitem_text_value":"Japan Society for Natural Disaster Science"}]},"item_2_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"後藤, 恵之輔"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"後藤, 健介"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"大田, 哲男"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-12-23"}],"displaytype":"detail","filename":"110002941725.pdf","filesize":[{"value":"1.4 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"110002941725.pdf","url":"https://nagasaki-u.repo.nii.ac.jp/record/15107/files/110002941725.pdf"},"version_id":"95158e53-31e9-4f41-b5f6-c39dd791a8df"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"リモートセンシング","subitem_subject_scheme":"Other"},{"subitem_subject":"塩害停電","subitem_subject_scheme":"Other"},{"subitem_subject":"台風","subitem_subject_scheme":"Other"},{"subitem_subject":"植物活性","subitem_subject_scheme":"Other"},{"subitem_subject":"remote sensing","subitem_subject_scheme":"Other"},{"subitem_subject":"salt-damage triggered power failure","subitem_subject_scheme":"Other"},{"subitem_subject":"typhoon","subitem_subject_scheme":"Other"},{"subitem_subject":"vegetation vigour","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"植物活性に着目した台風9119号による塩害停電のリモートセンシング解析","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"植物活性に着目した台風9119号による塩害停電のリモートセンシング解析"}]},"item_type_id":"2","owner":"2","path":["21"],"pubdate":{"attribute_name":"公開日","attribute_value":"2010-02-25"},"publish_date":"2010-02-25","publish_status":"0","recid":"15107","relation_version_is_last":true,"title":["植物活性に着目した台風9119号による塩害停電のリモートセンシング解析"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-05-16T00:11:54.935637+00:00"}