@article{oai:nagasaki-u.repo.nii.ac.jp:00015793, author = {長尾, 道彦 and 東, 克彦}, issue = {1}, journal = {長崎大学工学部研究報告, Reports of the Faculty of Engineering, Nagasaki University}, month = {Feb}, note = {A new method for turning off the SCR's in a variable time ratio controlled parallel inverter has been developed. The basis of this method is a third SCR inversely connectted with a center tap of a transformer. This inverter circuit is more simple, because it is composed of a small number of elements and minimum three SCR's, and has characteristic of very short reverse bias time, compared with conventional inverter. The inverter operates with a wide range of resistive, idnuctive and capasitive loads. The circuit is analyzed of three main modes of operation and calculated of a short reverse bias time., 長崎大学工学部研究報告, (1), pp.44-49; 1971}, pages = {44--49}, title = {最小三個のサイリスタを持つ可変時比率制御形並列インバータ}, year = {1971} }