{"created":"2023-05-15T16:41:28.481103+00:00","id":16138,"links":{},"metadata":{"_buckets":{"deposit":"6d434d6f-9c76-48f7-8b57-2ce770b91634"},"_deposit":{"created_by":2,"id":"16138","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"16138"},"status":"published"},"_oai":{"id":"oai:nagasaki-u.repo.nii.ac.jp:00016138","sets":["14:65"]},"author_link":["60616","60613","60614","60611","60615","60612"],"item_9_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2009-02","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"451","bibliographicPageStart":"447","bibliographic_titles":[{"bibliographic_title":"Applied Power Electronics Conference and Exposition, 2009. APEC 2009. Twenty-Fourth Annual IEEE"}]}]},"item_9_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper mentions the input current ripple reduction method of the Pulse-link DC-AC Converter for Fuel Cells. The conventional DC-AC converter for fuel cells is interpolated large capacitor between boost converter stage and PWM inverter stage. That capacitor disturbs the size reduction of this unit. To overcome this problem, authors have proposed a novel topology called as Pulse-link DC-AC converter. The proposed topology provides boosted-voltage pulse directly to PWM inverter. This topology does not require large capacitor between two stages. Instead, small values of inductor and capacitor are connected series and inserted between two stages in parallel. This paper examines the relationship between the inductor and capacitor values and input current-ripple. As the result, inductor value has the relationship with current-ripple.","subitem_description_type":"Abstract"}]},"item_9_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"24th Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2009; Washington, DC; 15 February 2009 through 19 February 2009","subitem_description_type":"Other"}]},"item_9_description_63":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"Applied Power Electronics Conference and Exposition, pp.447-451; 2009","subitem_description_type":"Other"}]},"item_9_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Institute of Electrical and Electronics Engineers"}]},"item_9_relation_9":{"attribute_name":"ISBN","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"978-1-4244-2811-3","subitem_relation_type_select":"ISBN"}}]},"item_9_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"(c)2009 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE."}]},"item_9_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Fukushima, Kentaro"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Norigoe, Isami"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Shoyama, Masahito"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Ninomiya, Tamotsu"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Harada, Yosuke"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tsukakoshi, Kenta"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-12-23"}],"displaytype":"detail","filename":"APEC09(4802696).pdf","filesize":[{"value":"145.3 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"APEC09(4802696).pdf","url":"https://nagasaki-u.repo.nii.ac.jp/record/16138/files/APEC09(4802696).pdf"},"version_id":"41d9d969-ac21-46db-b53d-7dc84e78ebfd"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"Input Current-Ripple Consideration for the Pulse-link DC-AC Converter for Fuel Cells by Small Series LC Circuit","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Input Current-Ripple Consideration for the Pulse-link DC-AC Converter for Fuel Cells by Small Series LC Circuit"}]},"item_type_id":"9","owner":"2","path":["65"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-07-08"},"publish_date":"2009-07-08","publish_status":"0","recid":"16138","relation_version_is_last":true,"title":["Input Current-Ripple Consideration for the Pulse-link DC-AC Converter for Fuel Cells by Small Series LC Circuit"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-05-17T20:56:19.803250+00:00"}