{"created":"2023-05-15T16:30:42.276125+00:00","id":1931,"links":{},"metadata":{"_buckets":{"deposit":"bd7199a1-b632-4b3d-bd1e-ca91f10cf361"},"_deposit":{"created_by":2,"id":"1931","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"1931"},"status":"published"},"_oai":{"id":"oai:nagasaki-u.repo.nii.ac.jp:00001931","sets":["14:21"]},"author_link":["8958","8955","8957","8956"],"item_2_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019-07-01","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"100","bibliographicPageStart":"90","bibliographicVolumeNumber":"190","bibliographic_titles":[{"bibliographic_title":"Engineering Structures"}]}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Concrete-filled steel tubular (CFST) K-joints have been widely applied to CFST trussed arch bridges \nin China, which are comprised of a concrete-filled circular hollow section (CHS) chord and two CHS braces.It has been experimentally revealed that hot spot stress (HSS) of CFST K-joints is significantly \nlower than those of empty tubular K-joints in the reported researches. However, no parametric formulae on stress concentration factors (SCFs) of CFST K-joints have been established. In present study,\n three-dimensional FE models for determining the SCF distributions around the chord-brace intersections of CFST K-joints were developed first. The validity of the FE modelling has been examined by comparing \nwith the published experimental results. Then 272 FE models of CFST K-joints with different geometric dimensions were prepared and provided for the parametric study to demonstrate the influence of four key geometric parameters, i.e. diameter ratio (β), diameter to thickness ratio of chord (2γ), thickness ratio (τ) and the angle (θ) between the axis of the chord and brace, on SCFs around the chord-brace intersection. The analysis was performed under three loading conditions, i.e. the basic balanced axial forces, axial compressive force in the chord and in-plane bending in the chord. Finally, parametric formulae to determine the SCFs in CFST K-joints were proposed \nby the multiple regression analysis, and their accuracy was demonstrated through the comparison of SCFs obtained by the proposed formulae and FEA.","subitem_description_type":"Abstract"}]},"item_2_description_63":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"Engineering Structures, 190, pp.90-100; 2019","subitem_description_type":"Other"}]},"item_2_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Elsevier Ltd."}]},"item_2_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1016/j.engstruct.2019.04.017","subitem_relation_type_select":"DOI"}}]},"item_2_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"c 2019 Elsevier Ltd. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/"}]},"item_2_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"01410296","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Zheng, Jian"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Nakamura, Shozo"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Okumatsu, Toshihiro"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Nishikawa, Takafumi"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-07-01"}],"displaytype":"detail","filename":"EngStr190_90.pdf","filesize":[{"value":"2.5 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"EngStr190_90.pdf","url":"https://nagasaki-u.repo.nii.ac.jp/record/1931/files/EngStr190_90.pdf"},"version_id":"7fb8e647-5c81-44c8-a159-3b3b776ab787"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"CFST K-joints","subitem_subject_scheme":"Other"},{"subitem_subject":"Stress concentration factors","subitem_subject_scheme":"Other"},{"subitem_subject":"Hot spot stress","subitem_subject_scheme":"Other"},{"subitem_subject":"Fatigue","subitem_subject_scheme":"Other"},{"subitem_subject":"Finite element analysis","subitem_subject_scheme":"Other"},{"subitem_subject":"Parametric formulae","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Formulation of stress concentration factors for concrete-filled steel tubular (CFST) K-joints under three loading conditions without shear forces","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Formulation of stress concentration factors for concrete-filled steel tubular (CFST) K-joints under three loading conditions without shear forces"}]},"item_type_id":"2","owner":"2","path":["21"],"pubdate":{"attribute_name":"公開日","attribute_value":"2020-12-18"},"publish_date":"2020-12-18","publish_status":"0","recid":"1931","relation_version_is_last":true,"title":["Formulation of stress concentration factors for concrete-filled steel tubular (CFST) K-joints under three loading conditions without shear forces"],"weko_creator_id":"2","weko_shared_id":2},"updated":"2023-05-15T23:00:08.587561+00:00"}