{"created":"2023-05-15T16:43:50.062101+00:00","id":19326,"links":{},"metadata":{"_buckets":{"deposit":"73c704b1-15d4-4fa1-b1b5-f2da36612a42"},"_deposit":{"created_by":2,"id":"19326","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"19326"},"status":"published"},"_oai":{"id":"oai:nagasaki-u.repo.nii.ac.jp:00019326","sets":["29:68:1348:1361"]},"author_link":["80343","80338","80340","80342","80339","80341"],"item_3_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2000-03-24","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"154","bibliographicPageStart":"153","bibliographicVolumeNumber":"13","bibliographic_titles":[{"bibliographic_title":"長崎大学医療技術短期大学部紀要"},{"bibliographic_title":"Bulletin of the School of Allied Medical Sciences, Nagasaki University","bibliographic_titleLang":"en"}]}]},"item_3_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"3社の耳式体温計を用いて耳内温測定値のばらつきの機器間差,測定値の機器間差,腋窩温との関係および相関について検討した. 耳内温のばらつきは1.3℃~0.1℃で2社は0.4℃以内が80%を占めていた.測定値の機器間差ではJ社の機器が他社に比べ高い傾向がみられた.耳内温と腋窩温の関係はどの機器も一定の傾向はみられなかった.耳内温と腋窩温の相関ではO社が最も高い相関を示し,ついでT社,J社の順であった. 各機器とも測定値に多少のばらつきはあったが,最高値と腋窩温の相関はみられたことから,複数回測定して最高値を採用することが望ましいと思われた.","subitem_description_type":"Abstract"}]},"item_3_description_64":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"長崎大学医療技術短期大学部紀要 = Bulletin of the School of Allied Medical Sciences, Nagasaki University. 2000, 13, p.153-154","subitem_description_type":"Other"}]},"item_3_source_id_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN10145685","subitem_source_identifier_type":"NCID"}]},"item_3_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"09160841","subitem_source_identifier_type":"ISSN"}]},"item_3_text_62":{"attribute_name":"sortkey","attribute_value_mlt":[{"subitem_text_value":"P00153-P00154"}]},"item_3_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"宮下, 弘子"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"宮原, 春美"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"浦田, 秀子"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"前田, 規子"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"中尾, 理恵子"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"辻, 慶子"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-12-23"}],"displaytype":"detail","filename":"iryou13_00_24_t.pdf","filesize":[{"value":"241.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"iryou13_00_24_t.pdf","url":"https://nagasaki-u.repo.nii.ac.jp/record/19326/files/iryou13_00_24_t.pdf"},"version_id":"df42df89-7ca0-4440-b12c-27faf9211de5"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"耳式体温計","subitem_subject_scheme":"Other"},{"subitem_subject":"機器間差","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"耳式体温計測定値の機器間差の検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"耳式体温計測定値の機器間差の検討"}]},"item_type_id":"3","owner":"2","path":["1361"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-07-01"},"publish_date":"2008-07-01","publish_status":"0","recid":"19326","relation_version_is_last":true,"title":["耳式体温計測定値の機器間差の検討"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-05-16T03:21:44.440313+00:00"}