{"created":"2023-05-15T16:44:12.454468+00:00","id":19824,"links":{},"metadata":{"_buckets":{"deposit":"34b189d3-690a-4ce8-9fc2-31005f2e68c8"},"_deposit":{"created_by":2,"id":"19824","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"19824"},"status":"published"},"_oai":{"id":"oai:nagasaki-u.repo.nii.ac.jp:00019824","sets":["29:30:1713167819629:1377"]},"author_link":["83014"],"item_3_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1986-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1/4","bibliographicPageEnd":"327","bibliographicPageStart":"322","bibliographicVolumeNumber":"31","bibliographic_titles":[{"bibliographic_title":"Acta Medica Nagasakiensia"}]}]},"item_3_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We investigated changes in oxygen consumption of the myocardium with respect to increase in subvalvular aortic stenosis, in 10 thoractomized mongrel dogs under anesthesia. A balloon catheter was advanced from the carotid artery and positioned under the aortic valve. The balloon was inflated by saline solution to produce subvalvular stenosis. Compared to pre-stenotic level the oxygen consumption remained almost unchanged at left ventricular pressure (PLV) and aortic pressure (PAo) gradient of up to 20 mmHg but showed about 15% increase at 40 mmHg and about 30% increase at 60 mmHg.. Coronary blood flow (CBF) also remained almost unchanged at pressure gradient of up to 20 mmHg but was decreased about 10% at 40 mmHg and about 20% at 60 mmHg.","subitem_description_type":"Abstract"}]},"item_3_description_64":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"Acta Medica Nagasakiensia. 1986, 31(1-4), p.322-327","subitem_description_type":"Other"}]},"item_3_source_id_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00508430","subitem_source_identifier_type":"NCID"}]},"item_3_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"00016055","subitem_source_identifier_type":"ISSN"}]},"item_3_text_62":{"attribute_name":"sortkey","attribute_value_mlt":[{"subitem_text_value":"P00322-P00327"}]},"item_3_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Igarashi, Katsuro"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-12-23"}],"displaytype":"detail","filename":"acta31_01-04_29_t.pdf","filesize":[{"value":"347.7 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"acta31_01-04_29_t.pdf","url":"https://nagasaki-u.repo.nii.ac.jp/record/19824/files/acta31_01-04_29_t.pdf"},"version_id":"24bc09fa-54fe-4490-8628-63ef79414268"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Oxygen consumption, subvalvular aortic stenosis","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Oxygen Consumption in Myocardium during Experimentally-induced Aortic Stenosis","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Oxygen Consumption in Myocardium during Experimentally-induced Aortic Stenosis"}]},"item_type_id":"3","owner":"2","path":["1377"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-06-20"},"publish_date":"2008-06-20","publish_status":"0","recid":"19824","relation_version_is_last":true,"title":["Oxygen Consumption in Myocardium during Experimentally-induced Aortic Stenosis"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2024-04-17T04:12:59.678634+00:00"}