ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 110 医歯薬学総合研究科 = Graduate School of Biomedical Sciences
  2. 110 学術雑誌論文 = Articles in academic journal

What Are the Factors Associated with Longevity of Mandibular Advancement Oral Appliances?

http://hdl.handle.net/10069/0002003594
http://hdl.handle.net/10069/0002003594
c630c1a1-7755-48ef-917c-61762a511622
名前 / ファイル ライセンス アクション
P7_134.pdf P7_134.pdf (410 KB)
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2026-01-13
タイトル
タイトル What Are the Factors Associated with Longevity of Mandibular Advancement Oral Appliances?
言語 en
言語
言語 eng
キーワード
言語 en
主題Scheme Other
主題 mandibular advancement oral appliances
キーワード
言語 en
主題Scheme Other
主題 obstructive sleep apnea syndrome
キーワード
言語 en
主題Scheme Other
主題 shared frailty analysis
キーワード
言語 en
主題Scheme Other
主題 failure
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Matsuda, Yasuhiro

× Matsuda, Yasuhiro

en Matsuda, Yasuhiro

Search repository
Magata, Nobuaki

× Magata, Nobuaki

en Magata, Nobuaki

Search repository
Tanoue, Naomi

× Tanoue, Naomi

en Tanoue, Naomi

Search repository
抄録
内容記述タイプ Abstract
内容記述 Background/Objectives: Mandibular advancement oral appliances (MAOAs) for obstructive sleep apnea syndrome treatment can be rendered more convenient by adopting a separate and movable design; however, concerns regarding possible weakening of effect have been raised. This study had the aim to clarify the factors associated with the longevity of separate and movable MAOAs. Methods: Information on 466 MAOAs from 230 patients was collected from medical records, including baseline information, apnea–hypopnea indexes, transcutaneous oxygen saturation, component connection method, and initial fabrication status (new fabrication or repair). MAOAs were evaluated in clinical practice, and breakage was considered a failure. Failures were classified into three types: Type A, breakage anywhere in MAOA; Type B, connector breakage (thermoplastic component breakage was censored); and Type C, thermoplastic component breakage (connector breakage was censored). Survival time of MAOA for all types was analyzed using a shared frailty model. Hazard ratios and 95% confidence intervals were determined, with the statistical significance at p < 0.05. Results: Type A failures were significantly linked to patient sex, age, and connection method; Type B failures were associated with sex and age; and no variables were linked to Type C failures. Younger male patients showed lower survival rate except for Type C, with no correlation between apnea symptom severity and survival status. Conclusions: MAOA connector strength was significantly associated with the MAOA survival rate. Connectors were more likely to break in younger patients, and this tendency was particularly pronounced in males. Therefore, age and sex should be considered when choosing the MAOA connection method.
言語 en
書誌情報 en : Prosthesis

巻 7, 号 6, p. art. no. 134, 発行日 2025-10-28
出版者
出版者 MDPI
言語 en
ISSN
収録物識別子タイプ EISSN
収録物識別子 2673-1592
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 https://doi.org/10.3390/prosthesis7060134
権利
権利情報 © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
言語 en
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
引用
内容記述タイプ Other
内容記述 Prosthesis, 7(6), art. no. 134; 2025
言語 en
戻る
0
views
See details
Views

Versions

Ver.1 2026-01-13 01:18:18.684547
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3