| アイテムタイプ |
学術雑誌論文 / Journal Article(1) |
| 公開日 |
2026-01-16 |
| タイトル |
|
|
タイトル |
Biomechanical effect of combined use of mini-screws and aligners in preventing uncontrolled tipping of the incisor and mesial tipping of the molar: a three-dimensional finite element study |
|
言語 |
en |
| 言語 |
|
|
言語 |
eng |
| キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Clear aligners |
| キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Finite element method |
| キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Mini-screws |
| キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Elastics |
| 資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
journal article |
| 著者 |
Yamaguchi-Higuchi, Runa
Hamanaka, Ryo
Komaki, Hiroya
Emori, Toshiro
Tominaga, Jun-ya
Horiguchi, Yui
Iwata, Sayaka
Ogawa, Kazuhiro
Kitaura, Arina
Yoshida, Noriaki
|
| 抄録 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
Background: This study aimed to evaluate the effect of external force applied from mini-screws to the aligner during space closure in extraction cases, and to determine the optimal loading conditions to prevent lingual crown tipping of the incisor and mesial tipping of the molar using the finite element (FE) method. Methodology: A three-dimensional FE model of the maxillary dentition with extraction of first premolars was constructed, and three different loading conditions were designed. The aligner was activated for 0.25 mm of incisor retraction without using mini-screws, with application of 0, 100, 200, or 300 cN of distal force through mini-screws placed in the posterior region, or with application of 0, 100, 200, 300, or 400 cN of intrusive force through mini-screws placed in the anterior region, in addition to the application of 300 cN of distal force. Results: As the magnitude of distal force increased, the degree of mesial tipping of the first molar gradually decreased, becoming almost zero with nearly 300 cN of distal force. As the magnitude of intrusive force increased in addition to the application of 300 cN of distal force, the degree of lingual crown tipping of the central incisor gradually decreased, becoming almost zero with nearly 400 cN of intrusive force. Conclusion: Application of 300 cN of distal force to the aligner from mini-screws placed in the posterior region could completely prevent mesial tipping of the molar and anchorage loss during anterior retraction. Application of 400 cN of intrusive force from mini-screws placed in the anterior region could prevent lingual crown tipping of the incisor, thus providing better torque control for the incisors. |
|
言語 |
en |
| 書誌情報 |
en : Progress in Orthodontics
巻 26,
号 1,
p. art. no. 54,
発行日 2025-12-29
|
| 出版者 |
|
|
出版者 |
Springer Nature |
|
言語 |
en |
| ISSN |
|
|
収録物識別子タイプ |
EISSN |
|
収録物識別子 |
2196-1042 |
| DOI |
|
|
関連タイプ |
isIdenticalTo |
|
|
識別子タイプ |
DOI |
|
|
関連識別子 |
https://doi.org/10.1186/s40510-025-00601-2 |
| 権利 |
|
|
権利情報 |
© The Author(s) 2025. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
|
言語 |
en |
| 著者版フラグ |
|
|
出版タイプ |
VoR |
|
出版タイプResource |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| 引用 |
|
|
内容記述タイプ |
Other |
|
内容記述 |
Progress in Orthodontics, 26(1), art. no. 54; 2025 |
|
言語 |
en |