{"created":"2023-05-15T16:46:44.308796+00:00","id":23141,"links":{},"metadata":{"_buckets":{"deposit":"f151c372-ed6f-4879-ab65-356ae71d3851"},"_deposit":{"created_by":2,"id":"23141","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"23141"},"status":"published"},"_oai":{"id":"oai:nagasaki-u.repo.nii.ac.jp:00023141","sets":["8:9"]},"author_link":["97631","97638","97634","97635","97633","97636","97637","97632"],"item_2_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2003-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"9","bibliographicPageEnd":"1234","bibliographicPageStart":"1229","bibliographicVolumeNumber":"26","bibliographic_titles":[{"bibliographic_title":"Biological & Pharmaceutical Bulletin"}]}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The objective of this study was to investigate the applicability of new oxygen meters with multi-channels and disposable oxygen electrode sensors (DOX-96) on the antimicrobial susceptibility testing of clinical bacterial isolates. The oxygen amount in the wells of 96-well plates was converted into current through electrodes. Bacterial inoculation decreased the oxygen amount in the wells because viable bacteria consume the oxygen. On the other hand, a failure of bacteria to consume oxygen was observed in the presence of potent antimicrobial agents, representing a serious arrest of bacterial metabolism usually leading to stasis or death. Based on these results, the minimum inhibitory concentration was determined by DOX-96 (MICdox). The MICdox showed good agreement with MIC measured by the standard broth microdilution method (98.2%). DOX-96 was also useful for turbid samples such as Mueller-Hinton broth containing 0.1% lipid emulsion. The MICdox in turbid samples showed good agreement with those in clear samples (100.0%). These results indicate that the newly developed DOX-96 is very useful in antimicrobial susceptibility testing even in turbid clinical samples such as colloidal products and turbid biological","subitem_description_type":"Abstract"}]},"item_2_description_63":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"Biological & Pharmaceutical Bulletin v.26(9) p.1229-1234, 2003","subitem_description_type":"Other"}]},"item_2_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Pharmaceutical Society of Japan"}]},"item_2_relation_11":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"12951463","subitem_relation_type_select":"PMID"}}]},"item_2_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1248/bpb.26.1229","subitem_relation_type_select":"DOI"}}]},"item_2_relation_42":{"attribute_name":"関係URI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"http://dx.doi.org/10.1248/bpb.26.1229"}]}]},"item_2_source_id_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA10885497","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"09186158","subitem_source_identifier_type":"ISSN"}]},"item_2_source_id_8":{"attribute_name":"EISSN","attribute_value_mlt":[{"subitem_source_identifier":"1347-5215","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kitahara, Takashi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Koyama, Nao"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Matsuda, Junichi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Hirakata, Yoichi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kamihira, Shimeru"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kohno, Shigeru"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Nakashima, Mikiro"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Sasaki, Hitoshi"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-12-24"}],"displaytype":"detail","filename":"BPBul26_1229.pdf","filesize":[{"value":"109.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"BPBul26_1229.pdf","url":"https://nagasaki-u.repo.nii.ac.jp/record/23141/files/BPBul26_1229.pdf"},"version_id":"ea562ac1-880e-48d0-8b76-c8642ba039b2"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"oxygen electrode","subitem_subject_scheme":"Other"},{"subitem_subject":"antimicrobial susceptibility testing","subitem_subject_scheme":"Other"},{"subitem_subject":"oxygen meter","subitem_subject_scheme":"Other"},{"subitem_subject":"minimum inhibitory concentration","subitem_subject_scheme":"Other"},{"subitem_subject":"lipid emulsion","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Evaluation of Newly Developed Oxygen Meters with Multi-Channels and Disposable Oxygen Electrode Sensors for Antimicrobial Susceptibility Testing","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Evaluation of Newly Developed Oxygen Meters with Multi-Channels and Disposable Oxygen Electrode Sensors for Antimicrobial Susceptibility Testing"}]},"item_type_id":"2","owner":"2","path":["9"],"pubdate":{"attribute_name":"公開日","attribute_value":"2007-10-12"},"publish_date":"2007-10-12","publish_status":"0","recid":"23141","relation_version_is_last":true,"title":["Evaluation of Newly Developed Oxygen Meters with Multi-Channels and Disposable Oxygen Electrode Sensors for Antimicrobial Susceptibility Testing"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-05-16T00:59:24.067938+00:00"}