@article{oai:nagasaki-u.repo.nii.ac.jp:00000238, author = {勝木, 健太 and 源城, かほり}, issue = {93}, journal = {長崎大学大学院工学研究科研究報告, Reports of Graduate School of Engineering, Nagasaki University}, month = {Aug}, note = {The objective of this study is to clarify thermal environment in summer and measures to improve thermal comfort for apartment houses with loft. Measurement of room temperature and numerical simulation were carried out using results of the measurement and multi-zone heat calculation program TRNSYS, the effects of night purge in loft space durin g summer on room temperature and cooling load were compared among five cities in Japan. This paper describes the results of numerical simulation of room temperature and cooling load using TRNSYS., 長崎大学大学院工学研究科研究報告, 49(93), pp.60-67; 2019}, pages = {60--67}, title = {夏季のロフト空間における夜間換気の効果に関する数値計算}, volume = {49}, year = {2019} }