@article{oai:nagasaki-u.repo.nii.ac.jp:00024401, author = {久保田, 英士 and 茂地, 徹 and 桃木, 悟 and 山田, たかし}, issue = {65}, journal = {長崎大学工学部研究報告, Reports of the Faculty of Engineering, Nagasaki University}, month = {Jul}, note = {Dioxins in the combustion gas of Municipal Solid Waste Incinerator(MSWI) are resynthesized during passing through the lower temperature region between the outlet exhaust boiler and the outlet gas duct. As a countermeasure , a spray water injection method is effective which prevents dioxins from resynthesizing by rapidly cooling down the gas temperature less than the temperature required for resynthesizing of dioxins. Using the evaporation rate of a water droplet calculated by Mizutani’s evaporation theory and the dioxins formation rate estimated by the theory of Altwicker and Stanmore, we have developed Excel program for predicting the combustion gas cooling rate and dioxins formation rate. A dioxins suppression factor was found to be dependent on the spray water droplet diameter. Therefore, some simulations have been done using real incinerator data. As a result, gas cooling rate, dioxins formation rate and dioxins product quantity can be estimated. If incinerator waste material element analysis will be available, the Excel program will be able to estimate the incinerator dioxins product quantity easily., 長崎大学工学部研究報告 Vol.35(65), pp.5-12; 2005}, pages = {5--12}, title = {都市ゴミ焼却炉ガス中のダイオキシン類の生成抑制に関する研究}, volume = {36}, year = {2005} }