{"created":"2023-05-15T16:49:17.593481+00:00","id":26682,"links":{},"metadata":{"_buckets":{"deposit":"d8d271dd-bf5a-45a8-b289-a7849d96f826"},"_deposit":{"created_by":6,"id":"26682","owners":[6],"pid":{"revision_id":0,"type":"depid","value":"26682"},"status":"published"},"_oai":{"id":"oai:nagasaki-u.repo.nii.ac.jp:00026682","sets":["14:15:16:2004"]},"author_link":["118170","118169"],"item_3_alternative_title_19":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Effect of Opening Openings in Buildings on Room Temperature and Cooling Load in Summer"}]},"item_3_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2021-07","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"97","bibliographicPageEnd":"32","bibliographicPageStart":"28","bibliographicVolumeNumber":"51","bibliographic_titles":[{"bibliographic_title":"長崎大学大学院工学研究科研究報告"},{"bibliographic_title":"Reports of Graduate School of Engineering, Nagasaki University","bibliographic_titleLang":"en"}]}]},"item_3_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The objective of this study is to clarify the effect of opening openings in buildings on room temperature and cooling load in summer with numerical calculation method. Numerical simulation was carried out for two rest rooms with different opening conditions of a western-style building in Nagasaki City using multi-zone heat calculation program TRNSYS. In addition, by examining the western-style building located in Nagasaki City where the passive design methods are adopted, the effects of passive cooling methods such as window opening were clarified.","subitem_description_type":"Abstract"}]},"item_3_description_64":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"長崎大学大学院工学研究科研究報告, 51(97), pp.28-32; 2021","subitem_description_type":"Other"}]},"item_3_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"118170","nameIdentifierScheme":"WEKO"}],"names":[{"name":"GENJO, Kahori"}]}]},"item_3_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"長崎大学大学院工学研究科"}]},"item_3_source_id_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12601998","subitem_source_identifier_type":"NCID"}]},"item_3_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"18805574","subitem_source_identifier_type":"ISSN"}]},"item_3_text_62":{"attribute_name":"sortkey","attribute_value_mlt":[{"subitem_text_value":"05"}]},"item_3_text_63":{"attribute_name":"出版者別言語","attribute_value_mlt":[{"subitem_text_value":"Graduate School of Engineering, Nagasaki University"}]},"item_3_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"源城, かほり"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-08-19"}],"displaytype":"detail","filename":"51_97_28.pdf","filesize":[{"value":"727.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"51_97_28.pdf","url":"https://nagasaki-u.repo.nii.ac.jp/record/26682/files/51_97_28.pdf"},"version_id":"48f7a11e-c254-46de-bbf7-9c5975e7be8f"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"building","subitem_subject_scheme":"Other"},{"subitem_subject":"opening","subitem_subject_scheme":"Other"},{"subitem_subject":"room temperature","subitem_subject_scheme":"Other"},{"subitem_subject":"cooling load","subitem_subject_scheme":"Other"},{"subitem_subject":"decarbonization","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"建物における開口部の開放が夏期の室温と冷房負荷に及ぼす影響","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"建物における開口部の開放が夏期の室温と冷房負荷に及ぼす影響"}]},"item_type_id":"3","owner":"6","path":["2004"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-08-19"},"publish_date":"2021-08-19","publish_status":"0","recid":"26682","relation_version_is_last":true,"title":["建物における開口部の開放が夏期の室温と冷房負荷に及ぼす影響"],"weko_creator_id":"6","weko_shared_id":-1},"updated":"2023-05-15T20:15:23.143435+00:00"}