{"created":"2023-05-15T16:49:18.035483+00:00","id":26693,"links":{},"metadata":{"_buckets":{"deposit":"93814695-cac6-47f5-9172-11b12614f45d"},"_deposit":{"created_by":6,"id":"26693","owners":[6],"pid":{"revision_id":0,"type":"depid","value":"26693"},"status":"published"},"_oai":{"id":"oai:nagasaki-u.repo.nii.ac.jp:00026693","sets":["14:21"]},"author_link":["118211","118212","118213","118214","118215"],"item_2_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2021-03-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"957","bibliographicPageStart":"947","bibliographicVolumeNumber":"33","bibliographic_titles":[{"bibliographic_title":"Sensors and Materials"}]}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We propose a method for detecting slug flow generated in horizontal pipes as a basic study for detecting slug flow generated in production facilities in oil and gas mining areas offshore. Generally, in process control, the damping function (low-pass filter) provided in a pressure sensor is used. However, in the proposed detection method, by not using such a damping function, the raw data measured by the existing sensor are sampled at a higher speed, and the obtained high-precision data are utilized. The effectiveness of the proposed detection method is confirmed by experiments and simulations.","subitem_description_type":"Abstract"}]},"item_2_description_63":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"Sensors and Materials, 33(3), pp. 947-957; 2021","subitem_description_type":"Other"}]},"item_2_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"M Y U Scientific Publishing Division"}]},"item_2_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.18494/SAM.2021.3253","subitem_relation_type_select":"DOI"}}]},"item_2_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"c 2021 M Y U Scientific Publishing Division. This work is licensed under a Creative Commons Attribution 4.0 International License. Sensors and Materials, 33(3), pp. 947-957; 2021, and DOI:10.18494/SAM.2021.3253"}]},"item_2_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0914-4935","subitem_source_identifier_type":"ISSN"}]},"item_2_source_id_8":{"attribute_name":"EISSN","attribute_value_mlt":[{"subitem_source_identifier":"2435-0869","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Shimomoto, Yoichi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Ikeda, Kenta"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Ogawa, Hiromitsu"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Nakatsu, Yuri"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yamamoto, Ikuo"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-09-10"}],"displaytype":"detail","filename":"SenMet33_947.pdf","filesize":[{"value":"1.8 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"SenMet33_947.pdf","url":"https://nagasaki-u.repo.nii.ac.jp/record/26693/files/SenMet33_947.pdf"},"version_id":"a2ac0265-8fd6-43a2-94f7-8f7f6b4c9486"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"slug flow","subitem_subject_scheme":"Other"},{"subitem_subject":"pressure fluctuation","subitem_subject_scheme":"Other"},{"subitem_subject":"horizontal pipeline","subitem_subject_scheme":"Other"},{"subitem_subject":"histogram","subitem_subject_scheme":"Other"},{"subitem_subject":"detection","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Detection of slug flow generated in horizontal pipeline","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Detection of slug flow generated in horizontal pipeline"}]},"item_type_id":"2","owner":"6","path":["21"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-09-10"},"publish_date":"2021-09-10","publish_status":"0","recid":"26693","relation_version_is_last":true,"title":["Detection of slug flow generated in horizontal pipeline"],"weko_creator_id":"6","weko_shared_id":-1},"updated":"2023-05-15T20:14:56.954262+00:00"}