{"created":"2023-05-15T16:49:36.535252+00:00","id":27124,"links":{},"metadata":{"_buckets":{"deposit":"82f0c16c-aa67-4068-9d8a-82c80d132e85"},"_deposit":{"created_by":6,"id":"27124","owners":[6],"pid":{"revision_id":0,"type":"depid","value":"27124"},"status":"published"},"_oai":{"id":"oai:nagasaki-u.repo.nii.ac.jp:00027124","sets":["10:11"]},"author_link":["120905","120903","120904","120902","120906","120907"],"item_2_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2022-01-14","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"art. no. 731","bibliographicVolumeNumber":"12","bibliographic_titles":[{"bibliographic_title":"Scientific Reports"}]}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Inverted internal limiting membrane (ILM) flap technique was developed to achieve macular hole (MH) closure in large MH and refractory cases. In this study, we evaluate the effect of the technique for small-medium size MH. We recruited patients who underwent vitrectomy for small-medium size (< 400 μm) MH with either inverted ILM flap technique (flap group) or with conventional ILM peeling (peeling group). Using propensity score, 21 eyes of 21 patients in the peeling group were matched against 21 eyes of 21 patients in the flap group. We compared MH closure rate, postoperative visual acuity, and recovery of the external limiting membrane (ELM) and ellipsoid zone (EZ). The MH closure rate was not different between the two groups (flap vs peeling: 90% vs 100%, P = 0.49). Whereas there was no significant difference in visual acuity improvement between the two groups, the flap group showed more disruption of the ELM 3 months after surgery and of the EZ at 3 and 6 months after surgery (P = 0.02, P = 0.03, and P = 0.04, respectively). The result suggested that inverted ILM flap technique does not have additional benefits for small-medium size MHs and may delay recovery of retinal integrity.","subitem_description_type":"Abstract"}]},"item_2_description_63":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"Scientific Reports, 12, art. no. 731; 2022","subitem_description_type":"Other"}]},"item_2_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Springer Nature"}]},"item_2_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1038/s41598-021-04739-x","subitem_relation_type_select":"DOI"}}]},"item_2_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© The Author(s) 2022. This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/."}]},"item_2_source_id_8":{"attribute_name":"EISSN","attribute_value_mlt":[{"subitem_source_identifier":"2045-2322","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Yamada, Kanako"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Oishi, Akio"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kusano, Mao"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kinoshita, Hirofumi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tsuiki, Eiko"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kitaoka, Takashi"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-02-28"}],"displaytype":"detail","filename":"SciRep12_731.pdf","filesize":[{"value":"1.2 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"SciRep12_731.pdf","url":"https://nagasaki-u.repo.nii.ac.jp/record/27124/files/SciRep12_731.pdf"},"version_id":"fee602c6-779e-42c2-8fe5-bdb9904bc7dc"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Effect of inverted internal limiting membrane flap technique on small-medium size macular holes","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Effect of inverted internal limiting membrane flap technique on small-medium size macular holes"}]},"item_type_id":"2","owner":"6","path":["11"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-02-28"},"publish_date":"2022-02-28","publish_status":"0","recid":"27124","relation_version_is_last":true,"title":["Effect of inverted internal limiting membrane flap technique on small-medium size macular holes"],"weko_creator_id":"6","weko_shared_id":-1},"updated":"2023-05-15T19:57:35.064966+00:00"}