{"created":"2023-05-15T16:50:06.997853+00:00","id":27843,"links":{},"metadata":{"_buckets":{"deposit":"2d36774f-611c-46d9-8731-41ac49fc323e"},"_deposit":{"created_by":6,"id":"27843","owners":[6],"pid":{"revision_id":0,"type":"depid","value":"27843"},"status":"published"},"_oai":{"id":"oai:nagasaki-u.repo.nii.ac.jp:00027843","sets":["10:11"]},"author_link":["124042","124041","124039","124040"],"item_2_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2022-12-22","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageStart":"96","bibliographicVolumeNumber":"28","bibliographic_titles":[{"bibliographic_title":"Molecules"}]}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Ubiquinone (UQ) is considered one of the important biologically active molecules in the human body. Ubiquinone determination in human plasma is important for the investigation of its bioavailability, and also its plasma level is considered an indicator of many illnesses. We have previously developed sensitive and selective chemiluminescence (CL) method for the determination of UQ in human plasma based on its redox cycle with dithiothreitol (DTT) and luminol. However, this method requires an additional pump to deliver DTT as a post-column reagent and has the problems of high DTT consumption and broadening of the UQ peak due to online mixing with DTT. Herein, an HPLC (high-performance liquid chromatography) system equipped with two types of online reduction systems (electrolytic flow cell or platinum catalyst-packed reduction column) that play the role of DTT was constructed to reduce reagent consumption and simplify the system. The newly proposed two methods were carefully optimized and validated, and the analytical performance for UQ determination was compared with that of the conventional DTT method. Among the tested systems, the electrolytic reduction system showed ten times higher sensitivity than the DTT method, with a limit of detection of 3.1 nM. In addition, it showed a better chromatographic performance and the best peak shape with a number of theoretical plates exceeding 6500. Consequently, it was applied to the determination of UQ in healthy human plasma, and it showed good recovery (\u001597.9%) and reliable precision (\u00146.8%) without any interference from plasma components.","subitem_description_type":"Abstract"}]},"item_2_description_63":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"Molecules, 28(1), art. no. 96; 2022","subitem_description_type":"Other"}]},"item_2_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"MDPI"}]},"item_2_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.3390/molecules28010096","subitem_relation_type_select":"DOI"}}]},"item_2_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/)."}]},"item_2_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1420-3049","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kishikawa, Naoya"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"El-Maghrabey, Mahmoud"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tobo, Miharu"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kuroda, Naotaka"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-01-19"}],"displaytype":"detail","filename":"M28_96.pdf","filesize":[{"value":"2.5 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"M28_96.pdf","url":"https://nagasaki-u.repo.nii.ac.jp/record/27843/files/M28_96.pdf"},"version_id":"bc4eedb3-603e-4493-8d79-6a2f4d2959e9"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"ubiquinone","subitem_subject_scheme":"Other"},{"subitem_subject":"redox cycle","subitem_subject_scheme":"Other"},{"subitem_subject":"electrolytic reduction","subitem_subject_scheme":"Other"},{"subitem_subject":"reduction column","subitem_subject_scheme":"Other"},{"subitem_subject":"human plasma","subitem_subject_scheme":"Other"},{"subitem_subject":"chemiluminescence","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"A Comparative Study on the Reduction Modes for Quinone to Determine Ubiquinone by HPLC with Luminol Chemiluminescence Detection Based on the Redox Reaction","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"A Comparative Study on the Reduction Modes for Quinone to Determine Ubiquinone by HPLC with Luminol Chemiluminescence Detection Based on the Redox Reaction"}]},"item_type_id":"2","owner":"6","path":["11"],"pubdate":{"attribute_name":"公開日","attribute_value":"2023-01-19"},"publish_date":"2023-01-19","publish_status":"0","recid":"27843","relation_version_is_last":true,"title":["A Comparative Study on the Reduction Modes for Quinone to Determine Ubiquinone by HPLC with Luminol Chemiluminescence Detection Based on the Redox Reaction"],"weko_creator_id":"6","weko_shared_id":-1},"updated":"2023-05-15T18:16:26.338535+00:00"}