{"created":"2023-05-15T16:31:53.638032+00:00","id":3500,"links":{},"metadata":{"_buckets":{"deposit":"49e17f02-b5ce-4bd1-ab29-4ef90c2ae364"},"_deposit":{"created_by":6,"id":"3500","owners":[6],"pid":{"revision_id":0,"type":"depid","value":"3500"},"status":"published"},"_oai":{"id":"oai:nagasaki-u.repo.nii.ac.jp:00003500","sets":["10:22:24"]},"author_link":["115422","115421"],"item_5_alternative_title_19":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"機械的繰返し荷重下における骨形成へのインプラントネックデザインの影響:ウサギ脛骨における組織形態とマイクロCT研究"}]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-08-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"178","bibliographicPageStart":"171","bibliographicVolumeNumber":"25","bibliographic_titles":[{"bibliographic_title":"Implant Dentistry"}]}]},"item_5_date_granted_64":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2016-08-03"}]},"item_5_degree_grantor_62":{"attribute_name":"学位授与機関","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_name":"Nagasaki University (長崎大学)"}],"subitem_degreegrantor_identifier":[{"subitem_degreegrantor_identifier_name":"17301","subitem_degreegrantor_identifier_scheme":"kakenhi"}]}]},"item_5_degree_name_61":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(歯学)"}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Purpose: The aim of this study was to investigate effects of implant neck design on the original concept of osseointegration and bone formation when applying mechanical repetitive loading by bone-integrated implants. Materials and Methods: Twenty-eight anodized Ti-6Al-4V alloy implants with +60° or -60° grooves in the implant neck were placed in the proximal tibial metaphysis of 14 rabbits. Fourteen implants received mechanical repetitive loading along the long axis of the implant for 8 weeks at 12 weeks after implant placement. The remaining 14 implants received no loading. Histomorphometric and microcomputed tomographic analyses were then performed. Results: No effect of neck design was observed without mechanical loading, whereas osseointegration around the +60° grooves was upregulated with mechanical loading. Calculated load effects on bone structure around the implant neck with +60° grooves were larger when compared with the -60° grooves under mechanical loading. Conclusions: These findings indicate that the establishment of osseointegration and bone formation around the implant neck with +60° grooves is superior to those with -60° grooves under loaded conditions.","subitem_description_type":"Abstract"}]},"item_5_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"長崎大学学位論文 学位記番号:博(医歯薬)甲第879号 学位授与年月日:平成28年8月3日","subitem_description_type":"Other"},{"subitem_description":"Author: Yasutake, Munenori; Kuroshima, Shinichiro; Ishimoto, Takuya; Nakano, Takayoshi; Sawase, Takashi","subitem_description_type":"Other"},{"subitem_description":"Citation: Implant Dentistry, 25(2), pp.171-178; 2016","subitem_description_type":"Other"}]},"item_5_description_69":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"Nagasaki University (長崎大学), 博士(歯学) (2016-08-03)","subitem_description_type":"Other"}]},"item_5_dissertation_number_65":{"attribute_name":"学位授与番号","attribute_value_mlt":[{"subitem_dissertationnumber":"甲医歯薬第879号"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"115422","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Yasutake, Munenori"}]}]},"item_5_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Lippincott Williams & Wilkins"}]},"item_5_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1097/ID.0000000000000384","subitem_relation_type_select":"DOI"}}]},"item_5_relation_42":{"attribute_name":"関係URI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://hdl.handle.net/10069/36847","subitem_relation_type_select":"HDL"}}]},"item_5_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"(C) 2016 Wolters Kluwer Health, Inc. All rights reserved."},{"subitem_rights":"This is a non-final version of an article published in final form in Implant Dentistry, 25(2), pp.171-178; 2016."}]},"item_5_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"10566163","subitem_source_identifier_type":"ISSN"}]},"item_5_text_67":{"attribute_name":"学位の種類","attribute_value_mlt":[{"subitem_text_value":"課程博士"}]},"item_5_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"安武, 宗徳"}],"nameIdentifiers":[{"nameIdentifier":"115421","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-02-01"}],"displaytype":"detail","filename":"ISYK879_Yasutake.pdf","filesize":[{"value":"1.0 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ISYK879_Yasutake.pdf","objectType":"fulltext","url":"https://nagasaki-u.repo.nii.ac.jp/record/3500/files/ISYK879_Yasutake.pdf"},"version_id":"9953f89e-9915-4dcf-b6f5-4b2dcd1a1f14"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Bone wound healing","subitem_subject_scheme":"Other"},{"subitem_subject":"Mechanical repetitive stimulation","subitem_subject_scheme":"Other"},{"subitem_subject":"Oriented grooves","subitem_subject_scheme":"Other"},{"subitem_subject":"Osseointegration","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"doctoral thesis","resourceuri":"http://purl.org/coar/resource_type/c_db06"}]},"item_title":"Influence of Implant Neck Design on Bone Formation Under Mechanical Repetitive Loading: Histomorphometric and Microcomputed Tomographic Studies in Rabbit Tibiae","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Influence of Implant Neck Design on Bone Formation Under Mechanical Repetitive Loading: Histomorphometric and Microcomputed Tomographic Studies in Rabbit Tibiae","subitem_title_language":"en"}]},"item_type_id":"5","owner":"6","path":["24"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2017-05-01"},"publish_date":"2017-05-01","publish_status":"0","recid":"3500","relation_version_is_last":true,"title":["Influence of Implant Neck Design on Bone Formation Under Mechanical Repetitive Loading: Histomorphometric and Microcomputed Tomographic Studies in Rabbit Tibiae"],"weko_creator_id":"6","weko_shared_id":-1},"updated":"2023-08-23T04:58:53.152816+00:00"}