{"created":"2023-05-15T16:32:09.721650+00:00","id":3895,"links":{},"metadata":{"_buckets":{"deposit":"052e3376-27c8-4760-9312-f2048b1e154a"},"_deposit":{"created_by":2,"id":"3895","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"3895"},"status":"published"},"_oai":{"id":"oai:nagasaki-u.repo.nii.ac.jp:00003895","sets":["29:30:1713167819629:262"]},"author_link":["15860","15859","15861","15858","15857"],"item_3_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"47","bibliographicPageStart":"45","bibliographicVolumeNumber":"61","bibliographic_titles":[{"bibliographic_title":"Acta medica Nagasakiensia"}]}]},"item_3_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The aim of this study was to establish a method for observing vocal fold vibration using a transnasal flexible fiberoptic endoscope and a high-speed camera for clinical use. We assembled a high-speed digital imaging system with an ordinary flexible endoscope and a highly sensitive high-speed camera (HAD-D71; DITECT Corporation, Tokyo, Japan) with ISO 5,000,000. The camera had an 8-GB internal storage memory for video capture of up to 7.0 s with the usual setting of 640 × 480 pixels\nat 4000 fps. Using the nasal route, the system enabled us to observe vocal fold vibration during running speech with adequate brightness and good image quality. Our high-speed digital imaging system with a flexible endoscope can be a useful option to observe vocal fold vibration during running speech and is an alternative to difficult transoral rigid endoscopy in patients complaining of voice problems.","subitem_description_type":"Abstract"}]},"item_3_description_64":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"Acta medica Nagasakiensia, 61(1), pp.45-47; 2017","subitem_description_type":"Other"}]},"item_3_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Nagasaki University School of Medicine"}]},"item_3_source_id_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00508430","subitem_source_identifier_type":"NCID"}]},"item_3_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"00016055","subitem_source_identifier_type":"ISSN"}]},"item_3_text_62":{"attribute_name":"sortkey","attribute_value_mlt":[{"subitem_text_value":"10"}]},"item_3_text_63":{"attribute_name":"出版者別言語","attribute_value_mlt":[{"subitem_text_value":"長崎大学医学部"}]},"item_3_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kaneko, Kenichi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Watanabe, Takeshi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kihara, Chiharu"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Sakaguchi, Koichi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Takahashi, Haruo"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-12-21"}],"displaytype":"detail","filename":"ActMed61_45.pdf","filesize":[{"value":"547.5 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ActMed61_45.pdf","url":"https://nagasaki-u.repo.nii.ac.jp/record/3895/files/ActMed61_45.pdf"},"version_id":"14337d07-6084-4714-84b3-7c7dac6e9d2e"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"high-speed digital imaging","subitem_subject_scheme":"Other"},{"subitem_subject":"transnasal flexible fiberoptic endoscopy","subitem_subject_scheme":"Other"},{"subitem_subject":"vocal fold vibration","subitem_subject_scheme":"Other"},{"subitem_subject":"voice disorders","subitem_subject_scheme":"Other"},{"subitem_subject":"running speech","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"High-speed digital imaging system with a transnasal flexible fiberoptic endoscope for observing vocal fold vibration","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"High-speed digital imaging system with a transnasal flexible fiberoptic endoscope for observing vocal fold vibration"}]},"item_type_id":"3","owner":"2","path":["262"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-03-16"},"publish_date":"2017-03-16","publish_status":"0","recid":"3895","relation_version_is_last":true,"title":["High-speed digital imaging system with a transnasal flexible fiberoptic endoscope for observing vocal fold vibration"],"weko_creator_id":"2","weko_shared_id":2},"updated":"2024-04-16T05:26:39.971579+00:00"}