{"created":"2023-05-15T16:33:05.526242+00:00","id":5190,"links":{},"metadata":{"_buckets":{"deposit":"d6436e8a-3b6a-47e0-a26f-7286c0bce1bb"},"_deposit":{"created_by":2,"id":"5190","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"5190"},"status":"published"},"_oai":{"id":"oai:nagasaki-u.repo.nii.ac.jp:00005190","sets":["14:65"]},"author_link":["21635","21636","21634"],"item_9_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2013","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"1537","bibliographicPageStart":"1532","bibliographic_titles":[{"bibliographic_title":"Electrical Machines and Systems (ICEMS), 2013 International Conference on"}]}]},"item_9_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The Modular Multilevel Converter (MMC) with full bridge cells is available for a utility interactive inverter in high voltage line. When it is interconnected with power line, it is possible to control the active power flow in order to supply or charge the power in the line. This research applied a Hexagonal MMC to 3-phase AC-AC conversion system. The system is controlled by internal model principle and MMC can operate reliably. Theory of the power flow control of MMC and effectiveness of the proposed control method in the simulation are presented.","subitem_description_type":"Abstract"}]},"item_9_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"2013 International Conference on Electrical Machines and Systems, ICEMS 2013; Busan; South Korea; 26 October 2013 through 29 October 2013","subitem_description_type":"Other"}]},"item_9_description_63":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"Electrical Machines and Systems (ICEMS), 2013 International Conference on, pp.1532-1537; 2013","subitem_description_type":"Other"}]},"item_9_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE"}]},"item_9_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1109/ICEMS.2013.6713319","subitem_relation_type_select":"DOI"}}]},"item_9_relation_9":{"attribute_name":"ISBN","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"9781479914470","subitem_relation_type_select":"ISBN"}}]},"item_9_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"c 2013 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works."}]},"item_9_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hamasaki, Shin-ichi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Okamura, Kazuki"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tsuji, Mineo"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-12-21"}],"displaytype":"detail","filename":"ICEMS2013_6713319.pdf","filesize":[{"value":"403.7 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ICEMS2013_6713319.pdf","url":"https://nagasaki-u.repo.nii.ac.jp/record/5190/files/ICEMS2013_6713319.pdf"},"version_id":"39b2355a-69a2-406c-9825-4ab250b35e05"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"AC/AC power converter","subitem_subject_scheme":"Other"},{"subitem_subject":"Internal model principle","subitem_subject_scheme":"Other"},{"subitem_subject":"Modular multilevel converter","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"Control of Modular Multilevel Converter based on bridge cells for 3-phase AC/AC converter","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Control of Modular Multilevel Converter based on bridge cells for 3-phase AC/AC converter"}]},"item_type_id":"9","owner":"2","path":["65"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-04-10"},"publish_date":"2014-04-10","publish_status":"0","recid":"5190","relation_version_is_last":true,"title":["Control of Modular Multilevel Converter based on bridge cells for 3-phase AC/AC converter"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-05-16T03:10:28.223988+00:00"}