{"created":"2023-05-15T16:33:41.243250+00:00","id":6017,"links":{},"metadata":{"_buckets":{"deposit":"aba7221f-15ab-4ee2-b83b-38c1e50f9052"},"_deposit":{"created_by":2,"id":"6017","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"6017"},"status":"published"},"_oai":{"id":"oai:nagasaki-u.repo.nii.ac.jp:00006017","sets":["10:11"]},"author_link":["26322","26323","26327","26328","26329","26330","26324","26325","26326"],"item_2_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2015-02","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"268","bibliographicPageStart":"266","bibliographicVolumeNumber":"21","bibliographic_titles":[{"bibliographic_title":"Liver Transplantation"}]}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Meticulous preoperative volumetry of the partial liver graft is essential for both assessing the postoperative graft function and to ensure the donor safety in the field of living donor liver transplantation (LDLT).\nWe herein report the case of a 53-year-old patient who underwent LDLT for hepatitis C virusinfected liver cirrhosis complicated with hepatocellular carcinoma. Preoperative 3D images were obtained using a 3D image analysis system to evaluate the graft volume and possible congested volume after implantation in LDLT, which revealed that a large middle hepatic vein drained a vast area in the right lobe. The extended left graft was considered to be small for size of the recipient, with an estimated congested area of 407 ml, which was equivalent to 39% of the donor’s liver volume in the remnant right lobe.\nWe decided to use a right lobe graft with the middle hepatic vein, because the volume was considered to be sufficient. A preoperative contrast-enhanced CT scan revealed a distance of 2 cm between the donor’s right hepatic vein and middle hepatic vein at the estimated Cantlie line. Because of the location, we planned to use autologous portal vein Y-graft interposition for the hepatic venous anastomosis. Three-dimensional printed solid models of the donor’s right lobe graft and the Y-graft from the recipient’s portal vein were also made for preoperative simulation using the Vincent program.\nBased on the estimation, we were able to evaluate whether to reconstruct the middle hepatic vein tributaries or anomalous hepatic veins in LDLT. The 3D solid model was effective for preoperative simulation and planning, which made it easy to imagine the reconstructed shape of the anastomosis with appropriate spatial perception.","subitem_description_type":"Abstract"}]},"item_2_description_63":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"Liver Transplantation, 21(2), pp.266-268; 2015","subitem_description_type":"Other"}]},"item_2_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"John Wiley and Sons Ltd"}]},"item_2_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1002/lt.24019","subitem_relation_type_select":"DOI"}}]},"item_2_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"c 2014 American Association for the Study of Liver Diseases"},{"subitem_rights":"This is the accepted version of the following article: Liver Transplantation, 21(2), pp.266-268; 2015, which has been published in final form at http://dx.doi.org/10.1002/lt.24019"}]},"item_2_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"15276465","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Baimakhanov, Zhassulan"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Soyama, Akihiko"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Takatsuki, Mitsuhisa"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Hidaka, Masaaki"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Hirayama, Takanori"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kinoshita, Ayaka"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Natsuda, Koji"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kuroki, Tamotsu"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Eguchi, Susumu"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-12-21"}],"displaytype":"detail","filename":"LivTra21_266.pdf","filesize":[{"value":"522.6 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"LivTra21_266.pdf","url":"https://nagasaki-u.repo.nii.ac.jp/record/6017/files/LivTra21_266.pdf"},"version_id":"37937ae8-62ce-48a5-a9ae-7f1ea6c03bc9"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Living donor","subitem_subject_scheme":"Other"},{"subitem_subject":"Liver transplantation","subitem_subject_scheme":"Other"},{"subitem_subject":"3D printed solid model","subitem_subject_scheme":"Other"},{"subitem_subject":"Autologous portal vein graft","subitem_subject_scheme":"Other"},{"subitem_subject":"3D imaging","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Preoperative simulation with a 3-dimensional printed solid model for one-step reconstruction of multiple hepatic veins during living donor liver transplantation","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Preoperative simulation with a 3-dimensional printed solid model for one-step reconstruction of multiple hepatic veins during living donor liver transplantation"}]},"item_type_id":"2","owner":"2","path":["11"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-03-01"},"publish_date":"2016-03-01","publish_status":"0","recid":"6017","relation_version_is_last":true,"title":["Preoperative simulation with a 3-dimensional printed solid model for one-step reconstruction of multiple hepatic veins during living donor liver transplantation"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-05-16T02:53:50.628063+00:00"}