{"created":"2023-05-15T16:29:21.156556+00:00","id":62,"links":{},"metadata":{"_buckets":{"deposit":"59c648b8-161b-4902-8095-54570c9b17e7"},"_deposit":{"created_by":2,"id":"62","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"62"},"status":"published"},"_oai":{"id":"oai:nagasaki-u.repo.nii.ac.jp:00000062","sets":["27:28"]},"author_link":["316","317","315","318"],"item_2_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2020-09-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"9","bibliographicPageEnd":"1286","bibliographicPageStart":"1281","bibliographicVolumeNumber":"27","bibliographic_titles":[{"bibliographic_title":"International Journal of Minerals, Metallurgy and Materials"}]}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"he surface treatment is important for titanium and its alloys as promising candidates for dental implantation due to their bioinert surface. Titanium surface samples were modified using H2O2 solution at different times up to 72 h to boost their bioactivity. According to the results of the field emission scanning electron microscopy test, some nanostructures are formed on the surface of treated titanium samples and increased in size by increasing the time of treatment up to 24 h. After 24 h of application, the sharpness of nanostructures decreased and the micro-cracks and discontinuity in the coating surface increased. \nThe results of the X-ray diffraction study and Raman spectroscopy revealed that anatase (TiO2) was formed on the surface \nof treated titanium samples. The peak intensity of Raman spectroscopy increased with an improvement in treatment time of\n up to 24 h and then decreased due to the discontinuity of the coating. Full wettability and ability to form apatite were reached \nat 6 h of treatment. It is clear that the treatment time has a significant effect on the surface treatment of titanium using \nthe H2O2 solution.","subitem_description_type":"Abstract"}]},"item_2_description_63":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"International Journal of Minerals, Metallurgy and Materials, 27(9), pp.1281-1286; 2020","subitem_description_type":"Other"}]},"item_2_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Springer Nature"}]},"item_2_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1007/s12613-020-2016-1","subitem_relation_type_select":"DOI"}}]},"item_2_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"c 2020, University of Science and Technology Beijing and Springer-Verlag GmbH Germany, part of Springer Nature. This is a post-peer-review, pre-copyedit version of an article published in International Journal of Minerals, Metallurgy and Materials. The final authenticated version is available online at: http://dx.doi.org/10.1007/s12613-020-2016-1"}]},"item_2_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"16744799","subitem_source_identifier_type":"ISSN"}]},"item_2_source_id_8":{"attribute_name":"EISSN","attribute_value_mlt":[{"subitem_source_identifier":"1869103X","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Khodaei, Mohammad"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Amini, Kamran"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Valanezhad, Alireza"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Watanabe, Ikuya"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-09-05"}],"displaytype":"detail","filename":"IJMMM27_1281.pdf","filesize":[{"value":"970.2 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"IJMMM27_1281.pdf","url":"https://nagasaki-u.repo.nii.ac.jp/record/62/files/IJMMM27_1281.pdf"},"version_id":"cccd0c7e-a8e7-40dd-9399-b05d94418875"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"anatase","subitem_subject_scheme":"Other"},{"subitem_subject":"dental implant","subitem_subject_scheme":"Other"},{"subitem_subject":"hydrogen peroxide","subitem_subject_scheme":"Other"},{"subitem_subject":"surface treatment","subitem_subject_scheme":"Other"},{"subitem_subject":"titanium implant","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Surface treatment of titanium dental implant with H2O2 solution","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Surface treatment of titanium dental implant with H2O2 solution"}]},"item_type_id":"2","owner":"2","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2020-12-16"},"publish_date":"2020-12-16","publish_status":"0","recid":"62","relation_version_is_last":true,"title":["Surface treatment of titanium dental implant with H2O2 solution"],"weko_creator_id":"2","weko_shared_id":2},"updated":"2023-05-15T22:59:27.291493+00:00"}