WEKO3
アイテム
{"_buckets": {"deposit": "e5bfd8ab-16b0-4e16-8d4e-67cf2cf01646"}, "_deposit": {"created_by": 2, "id": "14225", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "14225"}, "status": "published"}, "_oai": {"id": "oai:nagasaki-u.repo.nii.ac.jp:00014225", "sets": ["1194"]}, "author_link": ["51397", "51393", "51396", "51398", "51394", "51395"], "item_3_alternative_title_19": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Power Factor Correction by method of the Forced Reactive Power Circulation (power factor analysis and micro-computer cgntrol of the static power triple frequency changer)"}]}, "item_3_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1986-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "26", "bibliographicPageEnd": "26", "bibliographicPageStart": "19", "bibliographicVolumeNumber": "16", "bibliographic_titles": [{"bibliographic_title": "長崎大学工学部研究報告"}, {"bibliographic_title": "Reports of the Faculty of Engineering, Nagasaki University", "bibliographic_titleLang": "en"}]}]}, "item_3_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We have some methods for the power factor impruvement which are compensating capacitors, higher harmonics filters, polyphase-multistep and ac-chopper PWM etc. Then the equipment in circulating circuit which spends or absorbes electric power is inserted and electric power aren\u0027t regnerated in case of the inductive load. Thus reactive power are decrease and the input power factor are improved very much. Namely the \"method of forced circulating\" are thought. On the paper, power factor and higher harmonics are analyzed and illustrated with an example of 3f power changers in case of the method of forced circulating. In futuer, GTO typed 3f power changers are intended to control by micro-computer and improve output waveform by a power filter.", "subitem_description_type": "Abstract"}]}, "item_3_description_64": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "長崎大学工学部研究報告, 16(26), pp.19-26; 1986", "subitem_description_type": "Other"}]}, "item_3_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "51396", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Higashi, Katsuhiko"}]}, {"nameIdentifiers": [{"nameIdentifier": "51397", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Himeno, Takashi"}]}, {"nameIdentifiers": [{"nameIdentifier": "51398", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Takahashi, Ken-Ichiro"}]}]}, "item_3_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "長崎大学工学部"}]}, "item_3_source_id_10": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00178418", "subitem_source_identifier_type": "NCID"}]}, "item_3_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "02860902", "subitem_source_identifier_type": "ISSN"}]}, "item_3_source_id_8": {"attribute_name": "EISSN", "attribute_value_mlt": [{"subitem_source_identifier": "18805574", "subitem_source_identifier_type": "ISSN"}]}, "item_3_text_63": {"attribute_name": "出版者別言語", "attribute_value_mlt": [{"subitem_text_value": "Faculty of Engineering, Nagasaki University"}]}, "item_3_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "東, 克彦"}], "nameIdentifiers": [{"nameIdentifier": "51393", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "姫野, 隆"}], "nameIdentifiers": [{"nameIdentifier": "51394", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高橋, 賢一郎"}], "nameIdentifiers": [{"nameIdentifier": "51395", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-12-22"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "kogaku16_26_03.pdf", "filesize": [{"value": "614.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 614900.0, "url": {"label": "kogaku16_26_03.pdf", "url": "https://nagasaki-u.repo.nii.ac.jp/record/14225/files/kogaku16_26_03.pdf"}, "version_id": "81e8aaac-26a1-4cf6-b374-f425382da56c"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "強制循環方式による力率改善法(電力3f変換回路の力率解析とマイコン制御)", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "強制循環方式による力率改善法(電力3f変換回路の力率解析とマイコン制御)"}]}, "item_type_id": "3", "owner": "2", "path": ["1194"], "permalink_uri": "http://hdl.handle.net/10069/24197", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-10-13"}, "publish_date": "2010-10-13", "publish_status": "0", "recid": "14225", "relation": {}, "relation_version_is_last": true, "title": ["強制循環方式による力率改善法(電力3f変換回路の力率解析とマイコン制御)"], "weko_shared_id": -1}
強制循環方式による力率改善法(電力3f変換回路の力率解析とマイコン制御)
http://hdl.handle.net/10069/24197
http://hdl.handle.net/10069/24197684ae8f5-3251-4a6f-9062-6f48b9111294
名前 / ファイル | ライセンス | アクション |
---|---|---|
kogaku16_26_03.pdf (614.9 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-10-13 | |||||
タイトル | ||||||
タイトル | 強制循環方式による力率改善法(電力3f変換回路の力率解析とマイコン制御) | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
東, 克彦
× 東, 克彦× 姫野, 隆× 高橋, 賢一郎 |
|||||
著者別名 | ||||||
姓名 | Higashi, Katsuhiko | |||||
著者別名 | ||||||
姓名 | Himeno, Takashi | |||||
著者別名 | ||||||
姓名 | Takahashi, Ken-Ichiro | |||||
その他のタイトル | ||||||
その他のタイトル | Power Factor Correction by method of the Forced Reactive Power Circulation (power factor analysis and micro-computer cgntrol of the static power triple frequency changer) | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We have some methods for the power factor impruvement which are compensating capacitors, higher harmonics filters, polyphase-multistep and ac-chopper PWM etc. Then the equipment in circulating circuit which spends or absorbes electric power is inserted and electric power aren't regnerated in case of the inductive load. Thus reactive power are decrease and the input power factor are improved very much. Namely the "method of forced circulating" are thought. On the paper, power factor and higher harmonics are analyzed and illustrated with an example of 3f power changers in case of the method of forced circulating. In futuer, GTO typed 3f power changers are intended to control by micro-computer and improve output waveform by a power filter. | |||||
書誌情報 |
長崎大学工学部研究報告 en : Reports of the Faculty of Engineering, Nagasaki University 巻 16, 号 26, p. 19-26, 発行日 1986-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 02860902 | |||||
EISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 18805574 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00178418 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | 長崎大学工学部 | |||||
出版者別言語 | ||||||
Faculty of Engineering, Nagasaki University | ||||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 長崎大学工学部研究報告, 16(26), pp.19-26; 1986 |