ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 030 医学部 = School of Medicine
  2. 030 学術雑誌論文 = Articles in academic journal

Potential of Magnetic Resonance Plaque Imaging Using Superparamagnetic Particles of Iron Oxide for the Detection of Carotid Plaque

http://hdl.handle.net/10069/21932
http://hdl.handle.net/10069/21932
7f44e3dd-3b25-4e58-b639-df93443d8f68
名前 / ファイル ライセンス アクション
110006656285.pdf 110006656285.pdf (843.1 kB)
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2009-05-22
タイトル
タイトル Potential of Magnetic Resonance Plaque Imaging Using Superparamagnetic Particles of Iron Oxide for the Detection of Carotid Plaque
言語
言語 eng
キーワード
主題Scheme Other
主題 carotid plaque
キーワード
主題Scheme Other
主題 functional imaging
キーワード
主題Scheme Other
主題 high-resolution magnetic resonance imaging
キーワード
主題Scheme Other
主題 macrophage
キーワード
主題Scheme Other
主題 superparamagnetic particles of iron oxide
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Kawahara, Ichiro

× Kawahara, Ichiro

Kawahara, Ichiro

Search repository
Nakamoto, Morito

× Nakamoto, Morito

Nakamoto, Morito

Search repository
Kitagawa, Naoki

× Kitagawa, Naoki

Kitagawa, Naoki

Search repository
Tsutsumi, Keisuke

× Tsutsumi, Keisuke

Tsutsumi, Keisuke

Search repository
Nagata, Izumi

× Nagata, Izumi

Nagata, Izumi

Search repository
Morikawa, Minoru

× Morikawa, Minoru

Morikawa, Minoru

Search repository
Hayashi, Tomayoshi

× Hayashi, Tomayoshi

Hayashi, Tomayoshi

Search repository
抄録
内容記述タイプ Abstract
内容記述 Macrophages and by-products are important in plaque destabilization in atherosclerosis. Ultra-small superparamagnetic particles of iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging may be suitable for the detection of macrophages in atherosclerotic plaques. The present study investigated the potential of MR plaque imaging using SPIO in 10 patients scheduled for carotid endarterectomy before and 24-43 hours after administration of SPIO (fercarbotran, 0.016 ml/kg). Three-dimensional gradient recalled acquisition in the steady state (3D-GRASS) was used for detecting macrophages within plaques. Signal loss on the post-contrast 3D-GRASS images was found in 5 of 10 cases, and accumulation of SPIO particles in the vessel wall was confirmed in 4 of these 5 cases. Intracytoplasmic localization of SPIO particles within recruited macrophages was verified by double staining analysis. A correlation between MR plaque imaging using SPIO and localization of macrophages was demonstrated in 6 of 10 patients. This study indicates that MR plaque imaging using SPIO is a potential functional imaging tool to detect infiltration of macrophages in human atherosclerotic carotid plaque.
書誌情報 Neurologia medico-chirurgica

巻 48, 号 4, p. 157-162, 発行日 2008-04
出版者
出版者 The Japan Neurosurgical Society
ISSN
収録物識別子タイプ ISSN
収録物識別子 04708105
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN00358613
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 10.2176/nmc.48.157
権利
権利情報 Copyright (c) 2008 by The Japan Neurosurgical Society
権利
権利情報 本文データは学協会の許諾に基づきCiNiiから複製したものである
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
引用
内容記述タイプ Other
内容記述 Neurologia medico-chirurgica, 48(4), pp.157-162; 2008
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:57:54.806758
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3