{"_buckets": {"deposit": "7bb898b8-0505-4f7b-8eb3-d294dbccb181"}, "_deposit": {"created_by": 6, "id": "27905", "owners": [6], "pid": {"revision_id": 0, "type": "depid", "value": "27905"}, "status": "published"}, "_oai": {"id": "oai:nagasaki-u.repo.nii.ac.jp:00027905", "sets": ["11"]}, "author_link": ["124382", "124384", "124381", "124383"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2023-01-24", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageStart": "24", "bibliographicVolumeNumber": "12", "bibliographic_titles": [{"bibliographic_title": "Translational Vision Science \u0026 Technology"}]}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Purpose: To investigate the efficacy of the geometric morphometrics method for the evaluation of retinal deformation in patients with epiretinal membrane (ERM) and determine whether the degree of deformation can serve as a predictive factor for postoperative visual outcome.\nMethods: We retrospectively evaluated data from 29 eyes of 29 patients with primary ERM. Preoperative optical coherence tomography images were compared with images of their normal fellow eyes using the geometric morphometrics thin-plate spline technique. Conventional parameters such as retinal layer thickness and previously reported indices were also measured. The correlation between the preoperative parameters and visual acuity was evaluated. Statistical comparisons were performed using a paired t-test, and associations between the optical coherence tomography image parameters and visual acuity were determined using Spearman\u0027s rank correlation coefficient.\nResults: Bending energy, which was calculated using geometric morphometrics, was significantly associated with visual acuity as well as conventional optical coherence tomography parameters and previously reported indices. Multiple regression analysis showed that bending energy was an independent predictive factor for postoperative visual acuity changes.\nConclusions: The geometric morphometrics method is an effective approach for evaluating the severity of ERM and predicting the efficacy of surgery.\nTranslational Relevance: Geometric morphometrics can effectively evaluate retinal deformation in eyes with epiretinal membrane. ", "subitem_description_type": "Abstract"}]}, "item_2_description_63": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "Translational Vision Science and Technology, 12 (1), art. no. 24; 2023 ", "subitem_description_type": "Other"}]}, "item_2_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Association for Research in Vision and Ophthalmology Inc."}]}, "item_2_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1167/tvst.12.1.24", "subitem_relation_type_select": "DOI"}}]}, "item_2_rights_13": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "2023 The Authors This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 Internation"}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "2164-2591", "subitem_source_identifier_type": "ISSN"}]}, "item_2_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Miyagi, Sugao"}], "nameIdentifiers": [{"nameIdentifier": "124381", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Oishi, Akio"}], "nameIdentifiers": [{"nameIdentifier": "124382", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsuiki, Eiko"}], "nameIdentifiers": [{"nameIdentifier": "124383", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kitaoka, Takashi"}], "nameIdentifiers": [{"nameIdentifier": "124384", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2023-02-09"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "TVST12_24.pdf", "filesize": [{"value": "1.3 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1300000.0, "url": {"label": "TVST12_24.pdf", "url": "https://nagasaki-u.repo.nii.ac.jp/record/27905/files/TVST12_24.pdf"}, "version_id": "35bf934f-e192-494c-88f0-5de115227f70"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "retina", "subitem_subject_scheme": "Other"}, {"subitem_subject": "epiretinal", "subitem_subject_scheme": "Other"}, {"subitem_subject": "membrane", "subitem_subject_scheme": "Other"}, {"subitem_subject": "geometric morphometrics", "subitem_subject_scheme": "Other"}, {"subitem_subject": "optical coherence tomography", "subitem_subject_scheme": "Other"}, {"subitem_subject": "bending energy", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Geometric Morphometrics Can Predict Postoperative Visual Acuity Changes in Patients With Epiretinal Membrane: A Retrospective Study", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Geometric Morphometrics Can Predict Postoperative Visual Acuity Changes in Patients With Epiretinal Membrane: A Retrospective Study"}]}, "item_type_id": "2", "owner": "6", "path": ["11"], "permalink_uri": "http://hdl.handle.net/10069/00042039", "pubdate": {"attribute_name": "公開日", "attribute_value": "2023-02-09"}, "publish_date": "2023-02-09", "publish_status": "0", "recid": "27905", "relation": {}, "relation_version_is_last": true, "title": ["Geometric Morphometrics Can Predict Postoperative Visual Acuity Changes in Patients With Epiretinal Membrane: A Retrospective Study"], "weko_shared_id": -1}
Geometric Morphometrics Can Predict Postoperative Visual Acuity Changes in Patients With Epiretinal Membrane: A Retrospective Study
http://hdl.handle.net/10069/00042039
http://hdl.handle.net/10069/0004203991ef43d6-79e6-480d-94f4-609841b9e5f0
名前 / ファイル | ライセンス | アクション |
---|---|---|
TVST12_24.pdf (1.3 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2023-02-09 | |||||
タイトル | ||||||
タイトル | Geometric Morphometrics Can Predict Postoperative Visual Acuity Changes in Patients With Epiretinal Membrane: A Retrospective Study | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | retina | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | epiretinal | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | membrane | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | geometric morphometrics | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | optical coherence tomography | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | bending energy | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Miyagi, Sugao
× Miyagi, Sugao× Oishi, Akio× Tsuiki, Eiko× Kitaoka, Takashi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: To investigate the efficacy of the geometric morphometrics method for the evaluation of retinal deformation in patients with epiretinal membrane (ERM) and determine whether the degree of deformation can serve as a predictive factor for postoperative visual outcome. Methods: We retrospectively evaluated data from 29 eyes of 29 patients with primary ERM. Preoperative optical coherence tomography images were compared with images of their normal fellow eyes using the geometric morphometrics thin-plate spline technique. Conventional parameters such as retinal layer thickness and previously reported indices were also measured. The correlation between the preoperative parameters and visual acuity was evaluated. Statistical comparisons were performed using a paired t-test, and associations between the optical coherence tomography image parameters and visual acuity were determined using Spearman's rank correlation coefficient. Results: Bending energy, which was calculated using geometric morphometrics, was significantly associated with visual acuity as well as conventional optical coherence tomography parameters and previously reported indices. Multiple regression analysis showed that bending energy was an independent predictive factor for postoperative visual acuity changes. Conclusions: The geometric morphometrics method is an effective approach for evaluating the severity of ERM and predicting the efficacy of surgery. Translational Relevance: Geometric morphometrics can effectively evaluate retinal deformation in eyes with epiretinal membrane. |
|||||
書誌情報 |
Translational Vision Science & Technology 巻 12, 号 1, p. 24, 発行日 2023-01-24 |
|||||
出版者 | ||||||
出版者 | Association for Research in Vision and Ophthalmology Inc. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2164-2591 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1167/tvst.12.1.24 | |||||