{"_buckets": {"deposit": "5224a337-1fa5-4d05-bcb5-a284c6067a8e"}, "_deposit": {"created_by": 2, "id": "8798", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "8798"}, "status": "published"}, "_oai": {"id": "oai:nagasaki-u.repo.nii.ac.jp:00008798", "sets": ["646"]}, "author_link": ["35521", "35518", "35520", "35519"], "item_3_alternative_title_19": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Determination of Calcium by Chelatemetry Using Calcein―I.Determination of Calcium in Drinking Water and Sea Water"}]}, "item_3_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1964-09", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "116", "bibliographicPageStart": "106", "bibliographicVolumeNumber": "17", "bibliographic_titles": [{"bibliographic_title": "長崎大学水産学部研究報告"}, {"bibliographic_title": "Bulletin of the Faculty of Fisheries, Nagasaki University", "bibliographic_titleLang": "en"}]}]}, "item_3_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The method of determining calcium in drinking water by chelatometry (Calcein as an indicator) could not obtained reliable results under the hitherto employed condition, pH at the titration or the concentration of indicator etc., because of the improvement of reagent-purity. It is necessary to adjust the pH of sample to more than 12.5 and to dilute the concentration of indicator as far as ten to fifty times of it. For the adjustment of pH in the sample, a solution of potassium hydroxide was more suitable than sodium hydroxide solution used.", "subitem_description_type": "Abstract"}, {"subitem_description": "カルシウムのキレート滴定において,指示薬としてカルセインを使用する場合,最近純度の向上により,従来の定量条件は適用できない.飲料水,および海水を試料とする場合には次の条件で定量を行なうと好成績が得られた. 1. 高純度のカルセインでは一般の試水に対してマクロ法では0.2%,ミクロ法では0.1~0.02%が適する. 2. 滴定時のpHは12.5以上に保ち,その調節はKOHによる. 3. Na, Mg, Kイオンを多量に含有する試料では試料の大量希釈を行なうと共に,滴定時のpH 13.3~13.6,指示濃度0.02%,滴定液濃度0.0025M程度のミクロ法で行なう. 4. 滴定終点の判定には直射日光,または螢光燈下はさけ,間接光の下で行なう.", "subitem_description_type": "Abstract"}]}, "item_3_description_64": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "長崎大学水産学部研究報告, v.17, pp.110-116; 1964", "subitem_description_type": "Other"}]}, "item_3_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "35520", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Ishihara, Tadashi"}]}, {"nameIdentifiers": [{"nameIdentifier": "35521", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Yasuda, Masato"}]}]}, "item_3_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "長崎大学水産学部"}]}, "item_3_relation_29": {"attribute_name": "論文ID(NAID)", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "40018181177", "subitem_relation_type_select": "NAID"}}]}, "item_3_source_id_10": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00178473", "subitem_source_identifier_type": "NCID"}]}, "item_3_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "05471427", "subitem_source_identifier_type": "ISSN"}]}, "item_3_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "石原, 忠"}], "nameIdentifiers": [{"nameIdentifier": "35518", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "保田, 正人"}], "nameIdentifiers": [{"nameIdentifier": "35519", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-12-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "suisan17_110.pdf", "filesize": [{"value": "451.0 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 451000.0, "url": {"label": "suisan17_110.pdf", "url": "https://nagasaki-u.repo.nii.ac.jp/record/8798/files/suisan17_110.pdf"}, "version_id": "d1bcc3fa-c515-4e2f-a318-e82f425f0db7"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "カルセインを指示薬とするキレート滴定によるカルシウム定量法の検討―I : 飲料水・海水を試料とする定量法", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "カルセインを指示薬とするキレート滴定によるカルシウム定量法の検討―I : 飲料水・海水を試料とする定量法"}]}, "item_type_id": "3", "owner": "2", "path": ["646"], "permalink_uri": "http://hdl.handle.net/10069/31593", "pubdate": {"attribute_name": "公開日", "attribute_value": "2013-05-01"}, "publish_date": "2013-05-01", "publish_status": "0", "recid": "8798", "relation": {}, "relation_version_is_last": true, "title": ["カルセインを指示薬とするキレート滴定によるカルシウム定量法の検討―I : 飲料水・海水を試料とする定量法"], "weko_shared_id": -1}
カルセインを指示薬とするキレート滴定によるカルシウム定量法の検討―I : 飲料水・海水を試料とする定量法
http://hdl.handle.net/10069/31593
http://hdl.handle.net/10069/31593a4be8d9b-4ead-462b-85e2-736041ccdf61
名前 / ファイル | ライセンス | アクション |
---|---|---|
suisan17_110.pdf (451.0 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-05-01 | |||||
タイトル | ||||||
タイトル | カルセインを指示薬とするキレート滴定によるカルシウム定量法の検討―I : 飲料水・海水を試料とする定量法 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
石原, 忠
× 石原, 忠× 保田, 正人 |
|||||
著者別名 | ||||||
姓名 | Ishihara, Tadashi | |||||
著者別名 | ||||||
姓名 | Yasuda, Masato | |||||
その他のタイトル | ||||||
その他のタイトル | Determination of Calcium by Chelatemetry Using Calcein―I.Determination of Calcium in Drinking Water and Sea Water | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The method of determining calcium in drinking water by chelatometry (Calcein as an indicator) could not obtained reliable results under the hitherto employed condition, pH at the titration or the concentration of indicator etc., because of the improvement of reagent-purity. It is necessary to adjust the pH of sample to more than 12.5 and to dilute the concentration of indicator as far as ten to fifty times of it. For the adjustment of pH in the sample, a solution of potassium hydroxide was more suitable than sodium hydroxide solution used. | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | カルシウムのキレート滴定において,指示薬としてカルセインを使用する場合,最近純度の向上により,従来の定量条件は適用できない.飲料水,および海水を試料とする場合には次の条件で定量を行なうと好成績が得られた. 1. 高純度のカルセインでは一般の試水に対してマクロ法では0.2%,ミクロ法では0.1~0.02%が適する. 2. 滴定時のpHは12.5以上に保ち,その調節はKOHによる. 3. Na, Mg, Kイオンを多量に含有する試料では試料の大量希釈を行なうと共に,滴定時のpH 13.3~13.6,指示濃度0.02%,滴定液濃度0.0025M程度のミクロ法で行なう. 4. 滴定終点の判定には直射日光,または螢光燈下はさけ,間接光の下で行なう. | |||||
書誌情報 |
長崎大学水産学部研究報告 en : Bulletin of the Faculty of Fisheries, Nagasaki University 巻 17, p. 106-116, 発行日 1964-09 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 05471427 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00178473 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
論文ID(NAID) | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | NAID | |||||
関連識別子 | 40018181177 | |||||
出版者 | ||||||
出版者 | 長崎大学水産学部 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 長崎大学水産学部研究報告, v.17, pp.110-116; 1964 |